INAF queue observing, 2019 May 1-2

Observer: F. Cusano, A. Gargiulo
Telescope Operator: D. Gonzalez-Huerta
Support Astronomer: O. Kuhn
Instrument:

At the sunset the sky is covered by cirrus, we cannot use LBC. We cannot use MODS since it is dimissed.

Summary

Night duration (12 degree el twilight) 3:00 - 11:35 UT = 8 h 35m

Observing time: 5*h* 48*min* 61(%)

Weather time loss: 0*h* 0*min* 0(%)

technical time loss 2*h 45*min* 39(%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Calibrations dark for Marziani LUCI1/LUCI2        
Cresci HIP62745 LUCI1/LUCI2 G200-HK   luci1.0014-0017 luci2.0014-0017  
Cresci PSO-J183 LUCI1/LUCI2 G200-HK 2.16/2h luci1.0023-0048 luci2.0023-0048 completed
Cresci PSO-J183 LUCI1/LUCI2 K ima     completed
Annibali R37 LBC-B only g, r 0.66(g)-0.5(r)/1h   LBC-R not in use for panic on right side primary
Annibali R44 LBC-B only g, r 0.5(g)-0.33(r)/0.7h   LBC-R not in use for panic on right side primary don't use lbcb.20190502.112645.fits
Calibrations flat for Annibali (r band on LBC-blue) LBC-Blue        
Calibrations flat e arc for Cresci PSOJ183 - spec LUCI1/LUCI2        
Calibrations dark and flat for Cresci PSOJ183 - ima LUCI1/LUCI2        

Details

Calibrations
  • dark for Marziani luci1.20190502.0001-0010 luci2.20190502.0001-0010

02:31 seeing on 1.1"

02:38 we slew to Cresci's Telluric HIP62745
  • acq luci1.0011-0013 luci2.0011-0013
  • 02:48 seeing on dimm 0.86"
  • sci luci1.0014-0017 luci2.0014-0017

02:49 we slew to Cresci's target PSO-J183 - SPECTRA
  • guide star has a close companion. We change the guide star
  • 02:55 we send the script again
  • acq luci1.0018-0022 luci2.0018-0022
  • 03:04 seeing on dimm 0.71"
  • 03:09 some cirrus
  • 03:22 seeing on dimm 0.84"
  • 03:35 seeing on dimm 0.65"
  • 04:02 seeing on dimm 0.89"
  • 04:21 seeing on dimm 0.7"
  • sci luci1.0023-0048 luci2.0023-0048

04:27 we slew to Cresci's target PSO-J183 - IMAGING
  • 04:30 mos error
  • 04:44 we send the script again
  • 04:50 seeing 0.7"
  • 04:55 we align the camera N3.75

04:58 we slew to Bianchi's target Mrk1303 (LUCI/ESM)
  • 04:49 seeing on dimm
  • 05.14 loop closed, we send the script
  • 05:18 cannot find AOref star
  • 05:26 seeing on dimm 0.68"
  • 05:33 loop opens plus AO ref star issues. We decide to switch to LBC
  • 05:53 LBC is configured but mirror panic on dx
  • 08:00 we decide to use just LBC blue.

08:07 we slew to Annibali R37 (LBC Blue only)
  • 08:09 we send the script UGC_8638_1 (g band)
  • 08:11 dofpia, /Blueonly
  • NOTA: the LBC control system shows some glitch
  • 08:17 starting integration UGC_8638_1 (g band)
  • 08:18 seeing 0.9"
  • 08:46 dofpia, /Blueonly
  • 08:50 starting integration UGC_8638_1 (r band)
  • 08:57 fwhm on red images 0.7"
  • 09:16 starting integration UGC_8638_2 (g band)
  • 09:24 fwhm on red images 0.9"
  • 09:31 dofpia
  • 09:39 starting integration UGC_8638_2 (g band)
  • 09:53 dofpia
  • 09:55 starting integration UGC_8638_2 (r band)
  • 10:07 fwhm on images 1.2"
  • we change target: the airmass is too high and the seeing is getting worse

10:10 we slew to Annibali R44
  • 10:12 dofpia
  • 10:16 starting integration NGC6789_1 (g band)
  • 10:21 fwhm on images 1.0"
  • 10:35 fwhm on images 1.0"
  • 10:43 starting integration NGC6789_1 (r band)
  • 11:11 dofpia
  • 11:12 starting integration NGC6789_2 (g band)
  • we stop because the sky background is raising. do not use the last image lbcb.20190502.112645.fits

Calibrations
  • Flat for Annibali: r-band on LBC-B
  • Arc and Flat for Cresci PSOJ183 - spec
  • Dark and Flat-ima for Cresci PSOJ183 - ima
Topic revision: r8 - 09 May 2019, FeliceCusano
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback