INAF queue observing, 2019 April 26-27

Observer: F. Cusano, A. Gargiulo
Telescope Operator: D. Gonzalez-Huerta
Support Astronomer: O. Kuhn
Instrument:

We have a night shared with AZ, we have the second part of the night starting from 07:20 UT. at the sunset the sky is clear

Summary

Night duration (12 degree el twilight) 7:10- 11:35 UT = 4 h 25m (half a night)

Observing time: 3*h* 41*min*   83(%)

Weather time loss: 0*h* 0*min* (%)

technical time loss 0*h 44*min* 17(%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Nardini z3q1 LUCI1 G150-Ks 0.17/0.17h luci1.0017-0028 Completed
Nardini HIP61371 Luci1 G150-Ks   luci1.0009-0012  
A. Rossi 070521 LUCI2 ESM G200-HK 2/4h luci2.0017-0056  
A. Rossi HIP71172 LUCI2 G200-HK   luci2.0008-0011  
Calibrations arc,flat Nardini Rossi Cresci LUCI1/LUCI2        

Details

07:13 slowing to zenith to configure the telescope

07:25 problems with the secondary mirror
  • 07:42 problems fixed

07:48 Dimm seeing 1.3"
  • 07:53 FWHM on guider 0.98"

07:54 slew to Nardini telluric HIP61371
  • acq luci1.20190427.0006-0008
  • sci luci1.0009-0012

08:04 slew to Nardini science, target z3q1
  • dimm seeing 0.97"
  • acq luci1.0013-0016
  • sci luci1.0017-0028

08:32 slew to Andrea Rossi telluric HIP71172
  • 08:33 dimm seeing 1.0"
  • 08:34 the acquisition panel get stacked
  • 08:36 no guide star found
  • 08:37 mos error
  • 08:56 we send the script again
  • 08:59 dimm seeing 1.0"
  • acq luci2.0005-0007
  • sci luci2.0008-0011

09:07 slew to Andrea Rossi science, target 070521
  • 09:20 ESM loop closed
  • acq luci2.0012-0016
  • 09:34 seeing on guider 0.9"
  • 10:13 seeing on guider 1.0"
  • 10:24 seeing on guider 1.0"
  • 10:39 seeing on guider 1.0"
  • 10:53 seeing on guider 1.1"
  • 11:08 dimm seeing 1.1"
  • 11:23 the dimm seeing jump to 1.4"
  • 11:30 dimm seeing 1.2"
  • 11:41 dimm seeing 1.29"
  • 11:49 dimm seeing 1.22
  • sci luci2.0017-0056

Calibrations
  • flat for Rossi luci2.0057-0066
  • arc for Rossi luci2.0067-0072
  • flat for Nardini luci1.0029-0038
  • arc for Nardini luci1.0039-0044
  • dark for Cresci luci1.0045-49 luci2.0073-0077
  • flat for Cresci luci1.0050-54 luci2.0078-0082
  • arc for Cresci luci1.0055-58 luci2.0083-0086
Topic revision: r7 - 30 Apr 2019, FeliceCusano
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback