Clouds we stay closed

Night duration (12 degree el twilight) 2:00- 13:10 UT = 11 h 10m

Observing time: h min (0%)

Weather time loss: 11h 10m (100%)

technical time loss h m *(0%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Calibration Darks LUCI1-2        
Calibration bias, flat, arc MODS1-2       DeCarli,Rossi,Gilli

Details

2:15 starting LUCI dark
  • Antoniucci 2massJ06 luci1.20190130.0001-5, luci2.20190130.0001-5
  • Saracco ls luci1.20190130.0006-10, luci2.20190130.0006-10
  • Nardini q7 luci1.20190130.0011-20, luci2.20190130.0011-20
  • Antoniucci Iras 02 luci1.20190130.0021-25, luci2.20190130.0021-25
  • Marziani J085406 luci1.20190130.0026-30, luci2.20190130.0026-30
  • Marziani J093402 luci1.20190130.0031-35, luci2.20190130.0031-35
  • Gilli target M luci1.20190130.0036-40, luci2.20190130.0036-40
  • dark for telluric luci1.2.0190130.0041-60, luci2.20190130.0041-60
  • Antoniucci Iras 02 luci1.20190130.0061-65, luci2.20190130.0061-65 HKspec
  • Antoniucci 2massJ06 luci1.20190130.0066-70, luci2.20190130.0066-70 HKspec

6:20 starting MODS calibration
  • bias 4kx3k mods1r.20190130.0001-5, mods1b.20190130.0001-5 ; mods2r.20190130.0001-5,mods2b.20190130.0001-5
  • flat and arc red prism DeCarli mask mods1r.20190130.0006-30 ; mods2r.20190130.0006-30
  • 0.3" cal mods1r.20190130.0031-50 ; mods2r.20190130.0031-50
  • slit flat 5" mods1r.20190130.0052-60 ; mods2r.20190130.0051-60
  • flats imaging Rossi mods1r.20190130.0061, mods1b.20190130.0006 ; mods2r.20190130.0061,mods2b.20190130.0007

8:20 we try to open, there is an hole in the clouds

8:30 slewing to the program of Gilli mask33
  • acq mods1r.20190130.0061- , mods2r.20190130.0061-
  • 8:45 sky covered again