INAF queue observing, 2019 January 27-28

Observer: F. Cusano, A. Giunta
Telescope Operator: S. Allanson
Support Astronomer: O. Kuhn (on call)
Instrument:

Summary

Night duration (12 degree el twilight) 2:00- 13:10 UT = 11 h 10m

Observing time: h10. 50min (97%)

Weather time loss: 0h m (0%)

technical time loss h 20m *(3%)

Data Summary

at the sun set the sky is clear, wind at the limit 20 m/s

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Calibration Dark LUCI       darks for Gilli
Calibration Slitless flat MODS dual grating      
Rossi GRB MODS dual grating + ima 2.5h/2.5h    
Standard GD 71 MODS dual grating + red prism      
De Carli field MODS red prism 3h/7.5h   offset0, 1, 2, 3
Gilli mask31 MODS dual grating 2.67h/4h   completed
Saracco C1-23152 LUCI G200HKspec 2h/12h   completed
Telluric HIP56147 LUCI G200HKspec     telluric for Saracco
Nardini q7 LUCI G150 Ks 0.2h/0.5h   completed
Telluric HiP63193 LUCI G150 Ks     telluric for Nardini
Calibration flat, arc, dark MODS1-2        

Details

00:30 starting dark for Gilli program (still to do the telluric dark) luci1.20190128.0001-0005, luci2.20190128.0001-0005,

00:35 starting calibration with MODS, gxpixflat mods1 ands mods2, mods2 first three file have date 20190127

1:33 starting with MODS, slewing to Rossi grb190114
  • 1:36 error mechanis out of position, mask not in position for MODS1, going to higher elevation to put the mask in, 1:40 problem solved
  • acq mods1r.20190128.0009-0011, mods2r.20190128.0008-0010
  • sci mods1r.20190128.0012-15, mods1b.20190128.0011-14 ; mods2r.20190128.0011-14, mods2b.20190128.0009-12
  • 2:05 dimm seeing 1.3
  • 3:05 dimm seeing 1.2, airmass 2
  • 3:08 starting imaging, no guide star found, checking pointing, 3:12 sending again
  • img mods1r.20190128.0016-19, mods1b.20190128.0015-18 ; mods2r.20190128.0015-18, mods2b.20190128.0013-16

3:31 slewing to standard star, GD71
  • acq mods1r.20190128.0020-21, mods2r.20190128.0019-20
  • sci mods1r.20190128.0022-24, mods1b.20190128.0019-21 ; mods2r.20190128.0021-23, mods2b.20190128.0017-19 dual grating
  • sci mods1r.20190128.0025-27 ; mods2r.20190128.0024-26 red prism

4:05 slewing to science of DeCarli
  • 4:09 dimm seeing 1
  • acq mods1r.20190128.0028-30 ; mods2r.20190128.0027-29
  • sci mods1r.20190128.0031-41 ; mods2r.20190128.0030-40 offset0, starting from 4:48 offset1, starting from 5:17 offset2, 5:45 offset 3

6:15 slewing to Gilli mask 31
  • dimm seeing 1 at 6:27
  • acq mods1r.20190128.0042-44 ; mods2r.20190128.0041-43
  • sci mods1r.20190128.0045-48, mods1b.20190128.0022-25 ; mods2r.20190128.0044-47, mods2b.20190128.0020-23
  • 7:40 dimm seeing 0.8
8:02 switching to LUCI moon rise

8:21 slewing to Saracco, C1-23152
  • acq luci1.20190128.0006-9, luci2.20190128.0006-9
  • dimm seeing 0.8 at 8:16
  • dimm seeing 0.9 at 8:55
  • sci luci1.20190128.0010-33, luci2.20190128.0010-33
  • 9:58 dimm seeing 0.7
  • 10:33 dimm seeing 0.6

10:44 slewing to telluric of Saracco, HIP56147
  • acq luci1.20190128.0034-36, luci2.20190128.0034-36
  • sci luci1.20190128.0037-40, luci2.20190128.0037-40

11:05 slewing to Gilli L new
  • 11:05 dimm seeing 0.7
  • acq luci1.20190128.0041-50, luci2.20190128.0041-50
  • 11:07 guide star not found, checking the pointing, problem solved at 11:14, we fixed also a problem with the central wavelength manually
  • 11:10 problem with the script we change the acq, no should be ok
  • sci luci1.20190128.0051-66, luci2.20190128.0051-66
  • 11:49 dimm seeing 1.2
  • seeing is getting worst, now (12:03) dimm 1.6, seeing improving to 1 (12:10), now is getting better (12:16) seeing 0.9

12:47 slewing to Nardini q7
  • 12:47 dimm seeeing 0.8"
  • acq luci1.20190128.0067-70
  • sci luci1.20190128.0071-78

13:20 slewing to telluric of Nardini, HiP63193
  • acq luci1.20190128.0079-81
  • sci luci1.20190128.0082-85

13:55 starting MODS calibration, grlamp for MODS1 and MODS2
  • exec slitflats for MODS1 and MODS2 *
Topic revision: r6 - 01 Feb 2019, FeliceCusano
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback