INAF queue observing, 2018 Mar 21-22

Observer: R. Carini, A. Rossi
Telescope Operator: D. Gonzalez-Huerta
Support Astronomer: B Rothberg on call
Instrument: MODS1+MODS2, LBC

Summary

At the sunset sky is partly cloudy
instruments: all instruments work well Night duration (12\xB0 el twilight) 2:20am- 12:35pm UT = 10 h 15m

Observing time: 10h 15m (100%)

Weather time loss: 0h (0%)

technical time loss 0 (0%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
standard feige 34 MODS1+MODS2 dual grating   mods1r.0004-0006 , mods1b.0002-0004; mods2r.0004-0006 , mods2b.0002-0004  
Grazian A   MODS1+MODS2 dual grating longslit 30m/30m mods1r.0010-0011 , mods1b.0005-0006, mods2r.0010-0011 , mods2b.0005-0006 completed
Grazian J   MODS1+MODS2 dual grating MOS 4/8h mods1r.0015-0022 , mods1b.0007-0014 ; mods2r.0015-0022 , mods2b.0007-0014 first ~5 min in blue out from slit cause of atm refrac
Montalto wasp54 MODS1+MODS2 red only+blue only grating 2.3/2.3 mods1r.0026-0185; mods2b.0018-0174 Completed
calibrations spectral flat MODS1+MODS2 see the log     Antoniucci, Prandoni, Caccianiga
Cal imaging flat MODS 1+MODS2 dual; red: r, blue: g     Antoniucci

Details

02:16 start with standard star feige 34
  • acq mods1r.0002-03, mods2r.0002-03
  • sci mods1r.0004-0006 , mods1b.0002-0004, mods2r.0004-0006 , mods2b.0002-0004
  • think cirrus, but seeing 1.2 at 02:25

02:53 Slew to Grazian A
  • acq mods1r.0007-, mods2r.0007-
  • seeing 1.2 and cirrus at 02:54
  • sci mods1r.0010-0011 , mods1b.0005-0006, mods2r.0010-0011 , mods2b.0005-0006
  • 03:05 passing thick cirrus but we keep going

03:15 Slew to Grazian J
  • seeing 1" and cirrus at 03:20
  • acq mods1r.0012-14, mods2r.0012-14
  • sci execBinomods pointJ_mos_3.obs mods1r.0015-0016 , mods1b.0007-0008, mods2r.0015-0016 , mods2b.0007-0008
  • seeing 1" and cirrus at 03:36
  • note: we started a bit earlier than planned, thus in the first ~5-10 min (less than 1 exposure) the blue spectra is not in the 1.5" slit
  • seeing 1.1" and cirrus at 03:49
  • 04:11 execBinomods pointJ_mos_4.obs mods1r.0017-0018 , mods1b.0009-0010, mods2r.0017-0018 , mods2b.0009-0010
  • 04:47 execBinomods pointJ_mos_5.obs mods1r.0019-0020 , mods1b.0011-0012, mods2r.0019-0020 , mods2b.0011-0012
  • seeing about 1''
  • 05:03 cirrus are increasing
  • 05:25 execBinomods pointJ_mos_6.obs mods1r.0021-0022 , mods1b.0013-0014, mods2r.0021-0022 , mods2b.0013-0014
  • seeing about 1.0''

06:00 Slew to Montalto
  • acq mods1r.0023-25, mods2b.0015-0017
  • 06:15 execBinomods pointJ_mos_6.obs mods1r.0026-0186, mods2b.0018-0174
  • lost 2 min because wrong NIMGS parameter in the script. MaX is 99!!. Changed that, now it goes
  • start exposing at 06:23*
  • seeing 1.1" at 06:40
  • seeing 1.0" at 07:13, thin cirrus
  • seeing 0.9" at 07:13
  • cloud at 09:30, >1mag extinction on guider, still guiding well
  • seeing 0.9" at 09:48, clear again
  • 9:35 MODS2 stack, 9:54 we can restart MODS2
  • 10-10:30 UT 30 min with 0.5 mag extinction
  • seeing 0.9" at 10:33, other bunch of clouds at the horizon worried, confused
  • they did not affect us so much smile
  • 11:33 MODS error:images no displyed, we send red fitsflush
  • 11:33 the loaded stuck at ima mods1r.0157
  • 11:35 we start again the exposure, mods rstar to save the images, but we lost 2 images 158 and 159.
  • 12:00 seeing fluctuations 1"-1.3"
  • 12:36 seeing 0.6
  • 12:39 sky gets bright we stop and prepare for calibrations

Calibrations MODS
  • flat slit 0.8'' dual grating mods1r.0187-0192, mods1b.0015-0020; mods2r.0023-0028,mods2b.0175-0180 Antoniucci
  • flat slit 1.2'' dual grating mods1r.0193-0198, mods1b.0021-026; mods2r.0029-0034,mods2b.0181-0186==
  • flat slit 1.0'' red only mods1r.0199-0204; mods2r.0035-0043= Caccianiga, Prandoni
  • flat slit 1.2'' red only mods1r.0205-0210 MODS1 Caccianiga
  • flat slit 1.2'' blue only mods2b.0187-0192 MODS2, Prandoni
  • flat dual ima mods1r.0211-0215,mods1b.0027-0031; mods2r.0044-0048, mods2b.0193-0197 r,g

-- %USERSIG{RobertaCarini - 2018-03-22}%

Comments

 
Topic revision: r15 - 09 May 2018, FeliceCusano
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.