INAF queue observing, 2018 Feb 05-06

Observer: F. Cusano, A. Gargiulo
Telescope Operator: D. Gonzalez-Huerta
Support Astronomer: B. Rothberg
Instrument:

Summary

At the sunset the sky is clear
instruments: LBC works, LUCI2 is ok, LUCI 1 still MOS problem no AO and spec possible, MODS2 blue grating only

Night duration (12\xB0 el twilight) 2:00am- 13:15pm UT = 11 h 15m

Observing time: 10h 5m (89.6%)

Weather time loss: 0h m (0%)*

technical time loss 1h 10m (10.4%)

Data Summary

Project_RUN Objects Instrument Filter ExpTime Notes
LBC flat sky flat LBC B,r - V, i   check r,i counts
Cusano NW-1,2,3 LBC B, V 0.93h up to 21
Palazzi GRB171027A LBC r,r 0.47h  
Saracco C1_23152 LUCI2 200g HKspec 2h  
Gilli K LUCI2 200g HKspec 2h completed
Gilli L LUCI2 200g HKspec 0.33h  
Prandoni USS268 LUCI2 K, J 0.28h completed
LUCI2 cal dark LUCI2     Saraco, Gilli (sci,std), Nisini (spec)
LUCI1 cal dark LUCI1     Saracco (sci,std), Prandoni, Nisini (spec,ima)

Details

1:15 starting sky flat
  • B, V
  • r, i

1:36 slewing to Cusano NW-1
  • 1:40 dofpia
  • 1:49 copointing ob
  • 1:54 exec NW-1_19, 2:03 NW-2_19, NW-3_19
  • dimm seeing 0.7"
  • 2:02 seeing 0.9" images
  • 2:24 dofpia
  • 2:30 exec NW-1_20, NW-2_20, seeing 0.9" on images, NW-3_20
  • 2:52 seeing 0.8" on images
  • 2:57 exec NW1_21, NW-2_21

3:16 slewing to Palazzi copointing
  • 3:18 dofpia, problem with convergence, SA e TO are checking
  • 4:04 converged both side

4:04 slewing to Palazzi GRB171027A
  • 4:30 dimm seeing 0.9"

4:44 slewing to Rossi GRB180205A
  • 4:48 dimm seeing 0.8"
  • 5:05 blue is still not converging we switch to LUCI

5:05 we switch to LUCI
  • 5:26 problem with secondary DX * 5:46 problem solved

5:48 slewing to telluric of Saracco
  • dimm seeing 0.9"
  • acq luci2.20180206.0028-0030
  • spec 0031-34

5:59 slewing to Saracco science C1_23152
  • acq 35-38
  • spec 39-62
  • 6:11 seeing 8" on guider
  • 7:10 file 49-50 not good, collimation problems, pause the script 7:42, going again at 7:34
  • 7:54 seeing 0.8" on guider
  • 8:21 seeing 0.9"
  • 8:41 seeing 0.8"
  • 8:42 wind is raising (17 m/s)

8:46 slewing to telluric of Gilli * acq 63-65 * spec 66-69

8:58 slewing to Gilli K
  • 8:59 tata no guide star found, the TO is checking the pointing
  • 9:03 sending again the script
  • acq 70-73
  • 9:12 spec 74-109
  • 9:14 seeing 0.9" on guider
  • 9:39 seeing 0.9" *10:30 send again the spec script *10:41 seeing 1" on guider *11:11 seeing 1" on guider

11:41 slewing to telluric of Gilli
  • acq 110-112
  • spec 113-117
  • seeing 0.9" on guider

11:57 slewing to Gilli L
  • acq 118-120
  • 11:59 no guide star found, the TO is checking the pointing *12:02 send again the script
  • spec 121-125
  • 12:14* seeing 0.9"
  • 12:25 seeing jumping from 0.9" to 1.5"

12:33 slewing to Prandoni USS 268 K
  • 12:42 seeing 0.9"

12:46 slewing to Prandoni USS 268 J * 12:59 seeing 0.7" on guider
Topic revision: r4 - 07 Feb 2018, FeliceCusano
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback