INAF queue observing, 2017 Nov 23-24

Observer: F. Cusano, A. Gargiulo
Telescope Operator: S. Allanson
Support Astronomer: B. Rothberg
Instrument: MODS, LBC

Summary

At the sunset the sky is clear.
We start with MODS. At 06 UT we change to LBC

Night duration (12\xB0 el twilight) 1:30am- 12:40pm UT = 11 h 10m

Observing time: * *10h 40min*(95%)

Weather time loss: * *h (%)

technical time loss 30min h (5%)

Data Summary

Project_RUN Objects Instrument Filter ExpTime Notes
Caccianiga GB6J010135 +153845 MODS red grating 1.1h x 2 (bino) completed
Standard Feige 110 MODS red grating, dual grating    
Annibali DDT ssh MODS dual grating 2h x 2 (bino) completed
Cusano NW-1,2,3 LBC B; V 1.05h up to sequence 14
Annibali R12 UGC4426 LBC g; r 0.66h completed
Rossi GRB171010 LBC r; i 10min completed
Epifani 2013 UL10 LBC B; V-I 1.5h completed
Palazzi gw170817 LBC r; r 1h completed
skyflat   LBC r,r (LBC-B) ; I, z (LBC-R)    
modscal   MODS      

Details

01:11 slew to standard Feige_110
  • acquisition, acqBinoMODS Feige110 mods1r.20171124.0002-0003 ; mods2r.20171124.0002-0003
  • spectra dual grating , execBinoMods Feige110 mods1r.0004-6, mods1b.0002-4 ; mods2r.0004-6, mods2b.0002-4
  • seeing 0.8" on guider at 1:20
  • red grating, Feige 110 mods1r.0007-9 ; mods2r.0007-9

01:50 slew to Caccianiga GB6J010135 +153845
  • acqBinoMODS mods1r.00010-13 ; mods2r.00010-15
  • we can see the target and for this we refined the centering, because in MOD2 was a bit off the slit
  • starting science 2:12, execBinoMODS GB6J010135 +153845.obs, mods1r.00014-16 ; mods2r.00016-18

03:28 slew to Annibali DDT, SSH
  • seeing 0.6" on guider
  • acqBinoMODS mods1r.00017-19 ; mods2r.00019-21 even if the acq was set to 120 s the object was extremely faint and we centred using the finding chart in the possible position of the galaxy centre
  • execBinoMODS (dual grating), mods1r.0020-25, mods1b.0005-10 ; mods2r.0022-27, mods2b.0005-10

06:02 switch lo LBC

06:17 slewing to copointing of Cusano
  • 06:18 dohybryd
  • lbcrangebal

06:33 starting Cusano, exec NW-1_12.xml, NW-2_12, NW-3_12,
  • dimm seeing 0.6" ! at 06:41
  • seeing on images 0.7" at 06:50

07:01 dofpia

07:03 exec NW-1_13.xml, NW-2_13, NW-3_13

07:30 dofpia

07:35 exec NW-1_14.xml, NW-2_14.xml, NW-3_14.xml
  • seeing 0.8" on images at 07:51

08:02 slewing to Annibali R12 UGC4426, copointing
  • 08:05 dofpia
  • lbcrangebal

08:13 exec UGC4426_2.ob
  • dimm seeing 0.7" at 8:14

09:08 slewing to Rossi, GRB171010
  • 09:12 dofpia

09:16 exec LBT-2017B-C0883_1science.xml, GRB171010
  • seeing 0.6" on images

09:32 slewing to Epifani program
  • starting with PG0918.xml
  • 09:34 dofpia
  • 09:38 exec PG0918.xml, standard
  • 09:41 exec Pre2013UL10.xml, pre-obs sidereal
  • 09:45 starting non sidereal sequence, exec 2013UL10_1_11.xml, 2, 3, 4, 5 (dofpia at 10:22), 6, 7, 8, 9, 10, 11
  • dimm seeing 0.8" at 09:51
  • 11:10 exec Post2013UL10.xml, post-obs sidereal
  • 11:13 exec PG1047.xml, standard
  • 11:17 exec PG0918.xml, standard
  • 11:20 exec RU152.xml, standard

11:25 slewing to Annibali R13
  • 11:28 dofpia, problem with the LBC-B, the TO clears the active optics
  • 11:41 dofpia again, problem again with the LBC-B is not converging
  • 11:50 obs sent 1

11:56 slewing to Palazzi, exec LBT-2017B-C0831_2science.xml

12:59 starting sky flat r, I
  • skyflat r, z

13:48 starting MODS bias acquisition
  • exeBinoMODS bias8k.cal mods1r.0026-30, mods1b.0011-15 ; mods2r.0028-32, mods2b.0011-15
  • exeBinoMODS bias3k.cal mods1r.0031-35, mods1b.0016-20 ; mods2r.0033-37, mods2b.0016-20

14:10 starting MODS slitless flat exec
  • execMODS --mods1(2) --grpixflats(_mods2).cal (dual grating) mods1r.0036-40, mods1b.0021-30 ; mods2r.0038-42, mods2b.0021-30
  • execMODS --mods1(2) --grpixflats_r(_MODS2).cal (red grating) mods1r.0041-45 ; mods2r.0043-47

14:40 starting flat for standard stars
  • execMODS --mods1(2) --slitflat_5as(_mods2).cal (dual grating) mods1r.0046-48, mods1b.0031-36 ; mods2r.0048-50, mods2b.0031-36

13:01 how to make cranberry sauce
Topic revision: r8 - 05 Jul 2018, FeliceCusano
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback