INAF queue observing, 2017 Nov 22-23

Observer: F. Cusano, A. Gargiulo
Telescope Operator: S. Allanson
Support Astronomer: B. Rothberg
Instrument: LBC

Summary

At the sunset the sky is clear.
The support astronomer reported us that LBC observations at elevations lower than 30 degree are not feasable due to possible damage to the secondaries

Night duration (12\xB0 el twilight) 1:30am- 12:40pm UT = 11 h 10m

Observing time: 10h 50min*(97%)

Weather time loss: * *h (0%)

technical time loss 20min h (3%)

Data Summary

Project_RUN Objects Instrument Filter ExpTime Notes
bias   LBC      
flat   LBC B, r (LBC-B); V, i (LBC-R)  
Davanzo GRB170428A LBC g,r ; i, z 1h completed
Annibali R14 UGC5139 LBC g; r 1h completed
Cusano NW-1,2,3 LBC B; V 1.4h up to sequence 11
Annibali R5 KK17 LBC g; r 0.33h completed
Annibali R6 NGC784 LBC g; r 1h completed
Annibali R7 KKH37 LBC g; r 1h completed
Annibali R11 UGC4305 LBC g; r 1h completed
Annibali R12 UGC4426 LBC g; r 0.33h done ob 1
flat   LBC g, r (LBC-B); r, z (LBC-R)  

Details

00:00 bias for LBC, executing 25Bias_Bino

00:45 starting sky flat B, V
  • 00:54 starting r, i

01:10 slewing to Davanzo, GRB170428A
  • 01:12 executing dohybrid
  • 01:20 wrong co-pointing

01:28 executing GRB170428A _LBC.ob
  • seeing on images 1" at 1:35
  • seeing 0.9" at 1:56
  • 2:07 dofpia
  • 2:14 sending again GRB170428A _LBC.ob
  • seeing 0.8" at 2:21
  • 2:40 LBC-B has not good collimation

2:54 slewing to Annibali R14, UGC5139
  • 2:56 dofpia
  • 3:04 lbcrangebal

3:09 starting science UGC5139_1.ob
  • dimm seeing 0.85" at 3:12
  • seeing 0.7" on images at 3:16

3:36 executing UGC5139_2.ob
  • seeing 0.7" on images at 3:44
  • 4:02 dofpia

4:06 UGC5139_3.ob
  • seeing 0.7" on images at 4:13

4:34 slewing to Cusano program,
  • dofpia 4:36

4:44 executing NW-1_8.obs, NW-2_8, NW-3_8, NW-1_9, NW-2_9, NW-3_9, NW-1_10, NW-2_10,NW-3_10, NW-1_11, NW-2_11, NW-3_11
  • dimm seeing 0.9" at 4:53, seeing on images 0.75" at 4:54
  • 5:10 dofpia
  • seeing on images 0.8" at 5:25
  • 6:06 dofpia
  • seeing on images 0.9" at 06:12

06:39 slewing to Annibali R5
  • 06:40 dofpia
  • lbcrangebal

06:52 executing KK17_3.ob, Annibali R5
  • seeing on images 0.85" at 7:00
  • seeing on images 1" at 7:13
  • 7:16 exec calibration KK17_calib.ob

07:22 slewing to Annibali R6, NGC784
  • dofpia 07:23

07:27 exec NGC784_1.ob, Annibali R6
  • dimm seeing 0.8" at 7:27
  • seeing 1" on images

07:52 exec NGC784_2.ob
  • 08:17 run dofpia

08:22 exec NGC784_3.ob
  • dimm seeing 0.86" at 8:23
  • seeing on images 0.9" at 08:38

08:48 the TO resets the LBC control,

08:50 exec NGC784_calib.ob

08:56 slewing to Annibali R7, KKH37
  • dofpia 8:57
  • lbcrangebal

09:06 exec KKH37_1.ob
  • seeing on image 0.9" at 9:14

09:31 exec KKH37_2.ob
  • seeing on images 0.9" at 9:40

09:56 exec KKH37_3.ob
  • seeing 0.9" on images at 10:05

10:21 exec KKH37_calib.ob

10:28 slewing to Annibali R11, UGC4305
  • dofpia
  • lbcrangebal

10:39 exec UGC4305_1.ob
  • seeing on images 0.9" at 10:19

11:04 exec UGC4305_2.ob

11:30 dofpia

11:34 exec UGC4305_3.ob
  • seeing on images 0.6" ! at 11:53

12:01 exec UGC4305_calib

12:03 slewing to Annibali R12, UGC4426
  • 12:05 dofpia
  • lbcrangebal

12:17 exec UGC4426_1.ob
  • seeing on images 0.8" at 12:24

12:45 execUGC4426_2.ob, twilight started at 12:32, sky counts increasing, stopped after two exosures