INAF queue observing, 2016 July 4 - 5

Observer: F. Cusano, A. Rossi
Telescope Operator: G. Bechetti
Support Astronomer: O Kuhn on call
Instrument: LBC

Summary

At the sunset the sky is clear.
Still problem with the Dx AdSec we can not use LUCI2.
We use LBCs.

Night duration (12\xB0 el twilight) 20:30-4:00 ( 03:30-11.00 UT) = 7h 30m

Observing time: 7h10m (97%)

Weather time loss: 0 h (00%)

technical time loss 15m (3%)

Data Summary

Project_RUN Objects Filter ExpTime Notes
Momany NGC6205 SDT_U + r-sloan 2h  
Mignani J1907+0602 SDT_U,V + V,i-sloan 1h  
Mignani J2043+2740 SDT_U,V + V,i-sloan 1.5h completed
LBC flats        

Details

2:45 starting sky flats

3:31 slewing to Momany copointing
  • dofpia
  • copointing

3:45 sending Science_NGC6205.ob, Momany program
  • 3:50 seeing 0.7" on the images
  • image lbcr.20160705.035914.fits has four black squares, maybe not usefull
  • seeing 0.8" at 4:10

4:21 dofpia

4:29 executing Science_NGC6205.ob for the second time
  • 4:33 seeing 0.8"
  • 4:55 seeing 0.9"

5:05 dofpia

5:12 executing Science_NGC6205.ob for the 3rd time
  • 5:15 seeing 0.7"
  • 5:35 seeing 1.2"

5:50 dofpia

5:56 executing Science_NGC6205.ob for the 4th time
  • 6:00 seeing 1.1"
  • lbcr.55923 has four black rectangles on the image, not usefull

6:10 stop the ob, stars are elongated on the external frames, running dofpia

06:15 started the ob Science_NGC6205.ob again

06:51 slew to Mignani B2, copointing ob, 2015B_2_B2_pointing.ob
  • dofpia
  • lbcrangebal

7:07 sending science ob of Mignani B2, 2015B_2_B2_1.ob
  • seeing 1.2"
  • seeing 1" at 7:26

7:46 dofpia

07:49 2015B_2_B2_2.ob
  • seeing 1.2" at 8:15

08:30 slew to Mignani B3, copointing ob, 2015B_2_B3_pointing.ob
  • dofpia
  • lbcrangebal
  • =5 min tech loss due to error with lbcrangebal

8:45 sending science ob of Mignani B3, 2015B_2_B3_3.ob
  • seeing 0.6"
  • 9:05 stars elongated. stop OB and dofpia
  • 9:10 sending again 2015B_2_B3_3.ob
  • seeing 1.1"

9:50 dofpia + sending science ob of Mignani B3, 2015B_2_B3_4.ob
  • seeing 1.2"
  • some cirrus passing
  • seeing 1.1" at 10:05
  • seeing 1.1" at 10:30

10:32 dofpia + sending calib ob of Mignani B3, 2015B_2_B3_Cal.ob
  • = probably not useful because conditions do nto seem photometric =
  • seeing 1.2"

11:25 END