INAF queue observing, 2016 Jan 28-29

Observer: F. Cusano, A. Rossi
Telescope Operator: S. Allanson
Support Astronomer: Olga Kuhn
Instrument: LUCI/MODS

Summary

At the sunset some thin cirrus .

Night duration (12\xB0 el twilight) 19:20-6:10 ( 02:20-13:10 UT) = 10 h 50m

Observing time: 10 h m (96%)

Weather time loss: 0.5 h (4%)

technical time loss * 0h* 0m (0%)

Data Summary

Project_RUN Objects Filter ExpTime Notes
MODScalib        
DARKS     5x10s ok for Antoniucci, tellurics for several programs
Sarracco M004XLSms2 red-grating 1h program completed
Palazzi Eliana1 dual-grating    
Gilli id3605 zJ 1.5h completed
Guaita M1149 Brgam, Ks, H2 0.5h, 10min,0.5h  
DeBarros M103GLASS2c zJ 1.3h  

Details

00:32 MODS slitless flat dual grating mods1r.20160129.0002-0005, mods1b.20160129.0002-0010

01:39 slew to Saracco program
  • acqMods mods1r.20160129.0006-0008
  • seeing 0.8" on the guider at 1:41
  • spec mods1r.20160129.0009-0012
  • seeing 0.9" at 2:00
  • seeing 0.6" at 2:15

03:05 we slew to Palazzi Eliana1 with MODS
  • acqMods mods1r.20160129.0013-0015
  • seeing 0.5" on the guider at 3:10
  • 3:18 spec mods1b.20160129.0011-14 mods1r.20160129.0016-19
  • seeing 0.8" at 3:18
  • 04:08 start 5" slit OB on same target, spec mods1b.20160129.0015-0016; mods1r.20160129.0020-0021
  • seeing 0.7 on guider at 04:10

04:00 Darks for LUCI2, 1nditX10s mer luci2.20160129.0001-0005; 6nditX5s lir 0006-0010; 2nditx4s 0011-0015, 20nditx3s 0016-00

4:28 slew to standard GD71
  • acq mods1r.20160129.0022-0024
  • spec red grating mods1r.20160129.0025-0027; dual grating mods1b.20160129.0017-0019;mods1r.20160129.0028-0030

5:05 switch to LUCI + LBC-B
  • 5:30 dofpia while running collimation of LUCI

5:38 slew to telluric of Gilli
  • seeing 0.6" at 5:40
  • acq luci2.20160129.0021-0024
  • 5:48 spec luci2.20160129.0025-0027

5:53 slew to science of Gilli
  • acq luci2.20160129.0028-0031
  • seeing 0.5" at 6:04
  • spec luci2.20160129.0032-0049
  • 6:05 starting imaging with LBC-B, r filter, 62441 during offset
  • seeing 0.5" at 6:35
  • 6:40 dofpia
  • seeing 0.6" at 7:05
  • passing some cirrus during last 30 min
  • 7:20 dofpia

7:45 slew to Guaita standatd, P-550C
  • check pointing
  • ima luci2.20160129.0050-79
  • seeing 0.6 at 7:55

08:20 slew to Guaita M1149 Br_gam
  • ima luci2.20160129.0080-0111
  • images number 80 and 81 hare no ok due to bad guiding star (double and too bright)
  • seeing 0.5" at 08:21
  • seeing 0.5" at 08:45

09:11 Guaita M1149 Ks
  • ima luci2.20160129.0112-0141
  • seeing 0.7" on the guider at 9:13

09:58 Guaita M1149 H2
  • ima luci2.20160129.0142-0171
  • seeing 0.6" at 10:00

10:46 slewing to telluric of DeBarros
  • present failed the TO checks the pointing
  • seeing 0.6" at 10:51
  • acq luci2.20160129.0172-174
  • spec luci2.20160129.0175-0182

11:05 moving to science of DeBarros
  • seeing 0.6 at 11:05
  • acq luci2.20160129.0183-0186
  • 11:07 preset failed checking the pointing
  • 11:17 clouds coming in all aver the sky
  • 11:21 guide star fainting during the acquisition
  • waiting for clouds to pass 11:24 we did not star integration, guide star fainting 0.7 mag
  • 11:47 starting integration guide star is good now, spec luci2.20160129.0187-0202 seeing 0.7"
  • seeing 0.7" on guider at 12:15

13:20 starting sky flat with LBC-B filter U-Bessel

13:48 LUCI cal DeBarros
  • lamp luci2.20160129.0203-0208
  • arc luci2.20160129.0209-2011

MODS CALIB
  • grlamps.cal dual grating mods1b.20160129.0020-0022;mods1r.20160129.0031-0033
  • grlamps_r.cal red grating mods1r.20160129.0034-
 
Topic revision: r16 - 01 Feb 2016, FeliceCusano
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback