INAF queue observing, 2016 Jan 07-08

Observer: R. Carini, A. Marchetti
Telescope Operator: Steve Allanson
Support Astronomer: Olga Kuhn
Instrument:

Summary

dome is closed for snow and ice

Night duration (12\xB0 el twilight) 19:00-6:00 ( 02:00am-01:00pm UT) = 11 h 00m

Observing time: 0 hrs 0 m

Weather time loss: 11 hrs 00m (100%)

technical time loss 0 m

Data Summary

Project_RUN Objects Filter ExpTime Notes
Calibrations MODS Saracco,Nascimbeni,Antoniucci,Lanzuisi,Sommariva,standard stars red, dual grating

Details

02:05 wake up MODS1
  • take a test image mods1r.20160108.0001, mods1b.20160108.0001

02:20 begin the calibration for Saracco program
  • execMODS mods.4.XLSms2.cal mods1r.20160108.0002-0013 flat + arc
  • flat slitless red grating execMODS grpixflats_r.cal mods1r.0014-0018
  • flat in red grating long slit execMODS slitflats_r.cal mods1r.0019-0021
  • arc in red grating long slit execMODS grlamps_r.cal mods1r.0022-0024

03:56 calibration for Nascimbeni program
  • execMODS mods.2.GJ3470.cal mods1r.0025-0029, mods1b.0002-0006 flat + arc
  • flat slitless dual grating execMODS grpixflats.cal mods1r.0030-0034, mods1b.0007-0016
  • flat in dual grating long slit (0.6, 0.8, 1.0, 1.2) execMODS slitflats.cal mods1r.0035-0058, mods1b.0017-0040
  • arc in dual grating for standard star execMODS grlamps.cal mods1r.0059-0061, mods1b.0041-0043

06:22 test flat dual grating with slit 5 arcsec mods1r.0062-0068, mods1b.0044-0048

06:55 flat dual grating with slit 5 arcsec for the standard star, we send the script of Antoniucci modified, because the flats with his script are saturated.
  • execMODS dual_grating_5.0.flats.cal mods1r.0069-0071, mods1b.0049-0055

07:16 test flat red grating with slit 5 arcsec mods1r.0072-0075
  • we create a script for the flat red grating with a slit of 5 arcsec : slitflats_5as.cal, we save it in ScienceRuns /2015/MODS with PI name=All
  • execMODS slitflats_5as.cal mods1r.0073-0075

07:43 calibration for Sommariva program
  • execMODS ngc4189_mods.cal mods1r.0076-0080, mods1b.0056-0060
  • execMODS ngc4380_mods.cal mods1r.0081-0085, mods1b.0061-0065
  • execMODS ngc4579_mods.cal mods1r.0086-0090, mods1b.0066-0070

12:17 execMODS bias3K.cal (grating mode), mods1r.0087-0095, mods1b.0071-0075 bias8K.cal (Imaging mode) mods1r.0096-0100, mods1b.0076-0080

12:51 execMODS mods1Sleep.pro

-- %USERSIG{RobertaCarini - 2016-01-08}%

Comments

 
Topic revision: r9 - 17 Feb 2017, RobertaCarini
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback