INAF queue observing, 2015 30 Nov - 1 Dec

Observer: F. Cusano, A. Rossi
Telescope Operator: Steve Allanson
Support Astronomer: Barry Rothberg (on call)
Instrument: LUCI/LBC

Summary

At the sunset the sky has some cirrus at horizon.
The cirrus were complitely gone by 5 UT.

Night duration (12\xB0 el twilight) 18:20-6:00 ( 02:30-11:50 UT) = 11 h 40m

Observing time: 10 hrs 40 m (81%)

Weather time loss: (0%)

technical time loss 1 h (19%)

Data Summary

Project_RUN Objects Filter ExpTime Notes
LBC skyflat   LBC-B:B,r - LBC-R:V, I    
Clementini PegasusIII, PiscesII B, V 30m  
Iovino M004XXLrev grating 200H+K, filterzJ 3h 20min with cirrus
Guaita M0717 H2, Br_Gam 1h, 0.5h  
Gilli id3605 200H+K, filter zJ 1h  
calibration Gilli, Iovino    

Details

00:41 star flat field with LBC, filters LBC-B: B LBC-R:V

1:02 slewing to program of Clementini
  • copointing Pegasus
  • dofpia at 1:12
  • copointing 1:30

1:39 executing Pegasus_16.ob

1:44 Pisces_16.ob
  • seeing 0.9-1" measured on image

1:48 Pegaus_17.ob, Pisces_17.ob, Pegasus_18.ob, Pisces_18.ob, Pegasus_19.ob, Pisces_19.ob, Pegasus_20.ob, Pisces_20.ob

2:29 swith to LUCI2

2:52 slew to Iovino telluric
  • seeing 1"
  • acquisition =luci2.20151201.0002-004
  • spectra luci2.20151201.0005-0012

3:14 slew to the science field of Iovino, HK_spec +zJ filter
  • acquisition luci2.20151201.0013-0017
  • spectra luci2.20151201.0018-0029
  • some thin cirrus coming in at 4:00 maybe some spectra are not good, we keep going
  • at 4:20 the guider looks good the cirrus are passing
  • paused at 4:48 at spectra luci2.20151201.0025 too many cirrus
  • started again at 4:52, the guide star looks stable now (4:37)
  • seeing 1"

5:07 executing again the script Iovino HK_zJ
  • spectra luci2.20151201.0030-41
  • seeing 0.7"

6:15 executing again the script Iovino HK_zJ
  • spectra luci2.20151201.0042-53
  • seeing 0.9"

7:25 slew to Guaita H2 luci2.20151201.0054-113
  • seeing 0.9"
  • seeing 0.7" at 7:41
  • seeing 0.8" at 8:05
  • seeing 0.7" at 8:30
  • seeing 0.7" 9:00

9:06 slew to Guaita Br gamma luci2.20151201.0114-0143
  • seeing 0.9"
  • seeing 1" at the end of exposure

9:56 slew to Gilli Telluric
  • acquisition =luci2.20151201.0144-0149 =
  • changed the guide star
  • problem with the scheduler
  • spectra ==luci2.20151201.0150-0152 (150, satured the other are fine)

10:36 slew to Gilli science, id3605
  • acquisition luci2.20151201.153-157
  • spectra luci2.20151201.158-169
  • seeing 1.3" at 11:13
  • seeing 1" at 11:33

12:33 lost preset, doing the acquisition again
  • luci2.20151201.170 not good scheduler stuck
  • acquisition luci2.20151201.171-174
  • spectra luci2.20151201.175 problem with the GUI, end of the night

13:19 calibration Iovino
  • luci file luci2.20151201.176-194 not good
  • flat Halo1 luci2.20151201.195-200 we decreased the exposure time to 3 luci2.20151201.-205 too high counts
  • flat Halo3 luci2.20151201.201-212 too low counts
  • flat Halo2 luci2.20151201.213-218 counts ok use this!
  • arc lamp Xenon luci2.20151201.221, Argon luci2.20151201.223, Neon luci2.20151201.225

14:15 calibration Gilli
  • flat Halo2 luci2.20151201.229-234
  • arc lamp luci2.20151201.237, luci2.20151201.241, luci2.20151201.244
Topic revision: r12 - 20 Dec 2017, RobertaCarini
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback