INAF queue observing, 2015 Jun 23-24

Observer: F. Cusano, R. Carini
Telescope Operator: D. Gonzalez Huerta
Support Astronomer: David Thompson on call
Instrument: MODS, LUCI

Summary

At the sunset some cloud at the horizon, humidity 30%
At 02:42 clouds cover all the sky. The dome stay closed for the high probability chance of rain.
We perform dark test with LBC.

Night duration (12\xB0 el twilight) 20:30-4:00 ( 3:30-11:00 UT) = 7h:30m

Observing time: 2h 30m

Weather time loss: 5 hrs (67%)
Techical problem:

Data Summary

At the sunset partially cloudy, humidity

Project_RUN Objects Filter ExpTime Notes
Dark LBC dark   15mx3  
Antoniucci v2492cyg dual img + dual grating 3 m + 20m MODS COMPLETED
Antoniucci v2493cyg dual img + dual grating 3m + 20m MODS COMPLETED
Antoniucci PV Cep img + dual grating 3m + 20 m MODS COMPLETED
Calibration MODS

Details

03:00 we start LBC test lbcx.20150624.0....fits
  • 5BiasBino
  • 90 degree
  • 5BiasBino
  • 45 degree
  • 5BiasBino
  • 0 degree

08:27 TO opens the dome

08:48 Begin Antoniucci's program with MODS, target v2492cyg
  • execMODS v2492cyg.img mods1r.20150624.0002-0004, mods1b.20150624.0002-0004
  • seeing 1.5''

08:59 acqMODS v2492cyg.acq mods1r.20150624.0005-0007

08:06 execMODS v2492cyg_ls.obs mods1r.20150624.0008-0010, mods1b.20150624.0005-0007
  • seeing 1.2''

09:28 slew to target v2493cyg
  • execMODS v2493cyg.img mods1r.20150624.0011-0013, mods1b.20150624.0008-0011

09:42 acqMODS v2493cyg.acq mods1r.20150624.0014-0016

09:48 execMODS v2493cyg_ls.obs mods1r.20150624.0017-0018, mods1b.20150624.00012-0013

10:04 execMODS pvcep.img mods1r.20150624.0019-0021, mods1b.20150624.00014-0016

10:19 acqMODS pvcep_ls.acq mods1r.20150624.0022-0024
  • some clouds coming

10:27 execMODS pvcep_ls.obs mods1r.20150624.0025-0028, mods1b.20150624.00017-0020
  • seeing variable 1.15''-1.4''
  • humidity 60%

11:00 TO closes the dome

11:10 start the calibration
  • execMODS dual_grating_0.8_arc.cal mods1r.20150624.0029-0037, mods1b.20150624.00021-0029
  • 11:34 execMODS dual_grating_0.8_flat.cal mods1r.20150624.0038-0043, mods1b.20150624.00030-0035
  • execMODS imflats.cal mods1r.20150624.0044-0058, mods1b.20150624.00036-0045

-- %USERSIG{RobertaCarini - 2015-06-24}%

Comments

 
Topic revision: r6 - 25 Jun 2015, RobertaCarini
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback