INAF queue observing, 2015 Jun 20-21

Observer: F. Cusano, R. Carini
Telescope Operator: Steve Allanson
Support Astronomer: Olga Kuhn on call
Instrument: LBC, MODS

Summary

At the sunset the sky is clear, humidity 20%

Night duration (12\xB0 el twilight) 20:30-4:00 ( 3:30-11:00 UT) = 7 h 30m

Observing time: 7 hrs 30m

Weather time loss: 0 hrs (0%)

Data Summary

At the sunset the sky is clear, humidity 20%.

Project_RUN Objects Filter ExpTime Notes
Flat Field LBCr Y-fan, z sloan    
standard Sa107 Y-fan   airmass 1.25
Mignoli MOS 21 SDSSJ1411 M21 MODS red grating 2h  
Mignoli MOS 21 SDSSJ1411 M21 LBC r sloan 30 m  
Mignoli MOS 21 SDSSJ1411 M21 LBC z sloan 30 m  
Mignoli MOS 21 SDSSJ1411 M21 LBC i sloan 12 m  
standard star bd 332642 red + dual grating    
standard Sa107 Y-fan   airmass 1.4
Israel A7 CATSJ193437 dual grating 3 h COMPLETED
Antoniucci Q v2493cyg dual gratin 10 m only the first spectra are good
Calibration MODS        

Details

00:44 dark for MOONS project
  • dark at 90 degree
  • 5BiasBino
  • dark at 45 degree
  • 5BiasBino
  • dark at 0 degree

02:52 start with LBC flat field in Y, r

03:14 slew to the standard star Sa107
  • dofpia, /first, /redonly, /X2, give some problems, maybe the sky is too bright
  • we try with dofpia, /first, /redonly
  • sky is too bright, we wait some minutes

03:28 try again dofpia, /first, /redonly, not success
  • dofpia, /first, /redonly, /X2 not success

03:35 dofpia, /first, /redonly, /X2

03:40 send the ob SA107_Y.ob
  • seeing 0.5'', airmass 1.25

03:55 slew to Mignoli program MOS 21, in parallel mode MOSD + LBCR
  • 04.05 acqMODS mods.21..acq mods1r.20150621.0002-0004
  • seeing 0.8
  • 04:10 execMODS mods.21.4.obs mods1r.20150621.0005-0008
  • dofpia, /redonly, /X2
  • send 3_MOS21_r.ob

05:13 dofpia, /redonly, /X2

05:22 execMODS mods.21.5.obs mods1r.20150621.0008-0012
  • send 4_MOS21_z
  • seeing 0.9"
  • 05:50 seeing 1.0"
  • 06:08 seeing 1.2"

06:10 dofpia, /redonly, /X2
  • seeing 1.1"

06:15 send 5_MOS21_i *06:17 seeing variable, 1.9"

06:31 slew to the spectroscopic standard
  • acqMODS bd332642.acq mods1r.20150621.0012-0015
  • 06:40 execMODS bd332642.obs mods1r.20150621.0016-0018, mods1b.20150621.0002-0004 dual grating
  • seeing 0.8" - 0.9"
  • mods1r.20150621.0019-0021 red grating

06:55 dofpia, /redonly, /X2

07:05 slew to a photometric standard Sa107 again, to take the flux at different airmass (1.4)
  • send SA107_Y.ob. last image lbcr.20150621.071114

07:12 slew to Israel Program, Target A7
  • acqMODS catsj193435_ls.acq mods1r.20150621.0022-0024
  • the target is in y=622

07:32 execMODS catsj193435_ls.obs mods1r.20150621.0025-0028, mods1b.20150621.0005-008
  • seeing 0.8"
  • 09:13 seeing 0.7"
  • 09:56 seeing 0.9'' *10:29 seeing 1.0"

10:42 slew to Antoniucci program target Q
  • acqMODS v2493cyg_ls.acq, some problem with the acquisition, it is difficult discover the target mods1r.20150621.0029-0030
  • expecMODS v2493cyg_ls.obs mods1r.20150621.0031-0032,mods1b.20150621.0009-0010 mods1r.0032 and mods1b.0010 are not good

11:30 MODS calibrations
  • 11:40 begin with Israel : execMODS catsj193435_ls_arc.cal mods1r.20150621.0033,mods1b.20150621.0011
  • 11:49 execMODS catsj193435_ls_flat.cal mods1r.20150621.0034-38,mods1b.20150621.0012-0015

12:02 calibration for Mignoli
  • execMODS mods.21..cal mods1r.20150621.0039-0042 flat + arc

12:13 calibration for Antoniucci
  • execMODS dual_grating_0.8_arc.cal mods1r.20150621.0043-0051, mods1b.20150621.0016-0025
  • execMODS dual_grating_0.8_flat.cal mods1r.20150621.0052-0057, mods1b.20150621.0026-0031

-- %USERSIG{RobertaCarini - 2015-06-21}%

Comments

 
Topic revision: r10 - 25 Jun 2015, RobertaCarini
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback