INAF queue observing, 2015 Jun 19-20

Observer: F. Cusano, R. Carini
Telescope Operator: Steve Allanson
Support Astronomer: Olga Kuhn on call
Instrument: LBC, LUCI, MODS

Summary

At the sunset the sky is mostly cloudy, humidity 22%

Night duration (12\xB0 el twilight) 20:30-4:00 ( 03:30-11:00 UT) = 7 h 30m

Observing time: 7 hrs 30 m

Weather time loss: 0 hrs (0%)

Data Summary

At the sunset the sky is mostly clear, humidity 22%.

Project_RUN Objects Filter ExpTime Notes
Calibration flat field LBC Y-fan and LUCI J H bands
DDT Mignoli 3605 LBCR Y, LUCI J H 51 m with LBCR, LUCI: 30m J, 44m H  
standard Sa110 LBCR Y, LUCI J H    
standard Sa107 LBCR Y, LUCI J H    
Lardo M12 blue 1h COMPLETED
standard BD+33 2642 blue + dual grating    
Israel A6 catsj215544 dual grating 2 h COMPLETED
standard BD+24d4211 dual grating    
MODS calibrations

Details

02:45 start the flat field with LBC in Y-band and LUCI in H and J bands in parallel mode

03:35 run the LUCI script J1148_id3605_J.img luci.20150620.0037-0051
  • seeing 0.7'
  • send the preset with LBCR and do the collimation dofpia, /X2, /first , /redonly
  • there are some problems with the collimations : 'syntax error, at:/home/lbcobs/LBCFPIA/lbcfpia/src/anablob.pro'
  • Support astronomer tries to resolve the problem.
  • 4:00 the collimation works only from the lbto account

4:09 send the LBC ob
  • 04:15 seeing 1.4'

04:22 run the LUCI script J1148_id3605_H.img luci.20150620.0052-0072
  • seeing 1.0'
  • 04:38 seeing 1.26'
  • 05:16 seeing 1.3'

05:23 dofpia, /X2, /first , /redonly

05:32 we run the standard star Sa110 with LUCI in J luci.20150620.0073-0077 and H bands luci.20150620.0078-0082
  • dofpia, /X2, /first , /redonly
  • run the LBC ob in the Y band
  • 05:44 run again the LBC ob decreasing the time exposure

05:47 we run the standard star Sa107 with LUCI in J luci.20150620.0083-0087 and H bands luci.20150620.0088-0092
  • dofpia, /X2, /first , /redonly
  • run the LBC ob in the Y band
  • we sand again the LBC ob increasing the time exposure

05:58 we slew to Lardo program
  • configure MODS
  • take a test image modsr.20150620.0001.fits,modsb.20150620.0001.fits

06:20 acqMODS mods.8.M12.acq modsb.20150620.0002-0004 *06:32 execMODS mods.8.M12.obs modsb.20150620.0005-0007
  • seeing 1.5'
  • 07:08 seeing 1.3'

07:39 slew to the standard star BD+33 2642
  • acqMODS bd332642.acq modsr.20150620.0002-0004
  • execMODS bd332642.obs modsb.20150620.0008-0013, modsr.20150620.0005-0007
  • seeing 1'

08:20 slew to Israel program, target A6
  • acqMODS catsj215544_ls.acq modsr.20150620.0008-0010
  • 08:30 execMODS catsj215544_ls.obs modsr.20150620.0011-0013, modsb.20150620.0014-0016
  • seeing 0.9
  • 08:52 seeing 0.8

10:38 slew to standard BD+24d4211
  • acqMODS bd+24_ls.acq modsr.20150620.0014-0015
  • 10:52 execMODS bd+24_ls.obs modsr.20150620.0016-0020, modsb.20150620.0017-0021

11:07 TO closes the dome

11:16 begin the calibrations
  • Dark integrated LUCI luci.20150620.0093-0096 are not good
  • flat dual grating slitless with MODS: execMODS grpixflats.cal modsr.20150620.0021-0025, modsb.20150620.0022-0031
  • Bias with LBC : 25Bias_Bino

11:24 flash the detector

11:38 executeLUCIscript.sh integrated_darks.cal luci.20150620.0097-0106

11:46 flat blue grating slitless execMODS grpixflats_b.cal modsb.20150620.0032-0041

12:05 executeLUCIscript.sh normale_darks.cal luci.20150620.0107-010

12:07 arc dual grating per le standard: execMODS grlamp.cal modsr.20150620.0026-0028, modsb.20150620.0042-0044
  • 12:20 arc blue grating per le standard : execMODS grlamp_b.cal modsb.20150620.0045-0047
  • 12:30 flat slit 5 arcsec dual grating execMODS slitflat_5a.cal modsr.20150620.0029-0031, modsb.20150620.0048-0053
  • 12:48 flat slit 5 arcsec blue grating execMODS slitflats_b_5as.cal modsb.20150620.0054-0056
  • 12:56 execMODS Bias3K.cal modsr.20150620.0032-0036, modsb.20150620.0057-0061
  • execMODS Bias8K.cal modsr.20150620.0037-0041, modsb.20150620.0062-0066

01:10 calibrations for target Israel A6
  • execMODS catsj215544_ls_arc.cal modsr.20150620.0042, modsb.20150620.0067
  • execMODS catsj215544_ls_flat.cal modsr.20150620.0043-0047, modsb.20150620.0068-0072

01:40 calibrations for Lardo's target M12
  • flat+arc execMODS mods.8.M12.cal modsb.20150620.0073-0077

-- %USERSIG{RobertaCarini - 2015-06-20}%

Comments

 
Topic revision: r8 - 01 Oct 2015, RobertaCarini
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback