INAF queue observing, 2015 Apr 27-28

Observer: F. Cusano, R. Carini
Telescope Operator: Geno Bechetti
Support Astronomer: Dave Thompson on call
Instrument: LUCI

Summary

At the sunset clear sky

Night duration (12\xB0 el twilight) 20:00-04:30 (3:00-11.30 UT) = 8 hrs 30 m

Observing time: 8.30 hrs

Weather time loss: 0 hrs (0%)

Data Summary

At the sunset clear sky seeing 0.7-0.8

Project_RUN Objects Filter ExpTime Notes
Piconcelli B1 standard HIP52877 H    
Piconelli B1 1106+6400 H 0.5 h COMPLETED
Piconcelli A5 standard HIP41798_Intermediate Ks
Piconcelli A5 1201+0116 Ks 0.4 h COMPLETED
Della Ceca F standard HIP67848_A0V HKspec    
Della Ceca F 2XMMJ135055.7+642857 HKspec 2 h COMPLETED
Della Ceca G standard HIP67848_A0V HKspec  
Della Ceca G 2XMMJ143623.8+631726 HKspec 2 h COMPLETED
Piconcelli A6 1535+0855 Ks 0.4 h COMPLETED
Piconcelli A6 standard HIP75230 Ks    

Details

02:35 test LUCI luci.20150428.0001

02:40 seeing 0.7-0.8

02:44 acquisition standard of the program Piconcelli B1
  • executeLUCIScript.sh tellB1_LS_JHeI.acq luci.20150428.0002-0006

02:54 executeLUCIscript.sh tellB1_LS_210_H.spec luci.20150428.0007-0008
  • seeing 0.64

02:56 slew to the target B1
  • executeLUCIScript.sh B1_LS_H.acq luci.20150428.0009-0012

03:07 executeLUCIScript.sh B1_LS_210_H.spec luci.20150428.0013-0018
  • seeing 0.6-0.7
  • 03:38 seeing 0.78

03:42 slew to the standard stars for A5 target
  • executeLUCIScript.sh A5_LS_HeIJ_tell.acq luci.20150428.0019-0021
  • executeLUCIScript A5_LS_HeIJ_tell.spec luci.20150428.0022-0023

4:00 slew to the target A5
  • executeLUCIScript A5_LS_Ks.acq luci.20150428.0024-0027
  • executeLUCIScript A5_LS_Ks.spec luci.20150428.0028-0030

4:42 slew to standard for the Della Ceca program target F
  • executeLUCIScript.sh Target_11F_tell.acq luci.20150428.0031-0033
  • executeLUCIScript.sh Target_11F_tell.spec luci.20150428.0034-0035

5:00 slew to Target F
  • executeLUCIScript.sh Target_11F.acq luci.20150428.0036-0041
  • seeing 1-1.5
  • the target is very faint, we increases the exposure time end do again the acquisition
  • executeLUCIScript.sh Target_11F.acq luci.20150428.0042-0045
  • seeing 1-05-1.25

5:45 executeLUCIScript.sh Target_11F.spec luci.20150428.0046-0057
  • 06:02 seeing 0.7
  • 07:19 seeing 0.9

7:53 slew to Target G, acquisition of the standard star
  • executeLUCIScript.sh Target_11G_tell.acq luci.20150428.0058-0060
  • seeing 0.6-0.7
  • executeLUCIScript Target_11G_tell.spec luci.20150428.0061-0062

08:05 science acquisition Target G
  • executeLUCIScript.sh Target_11G.acq luci.20150428.0063-0066
  • seeing0.75
  • executeLUCIScript.sh Target_11G.spec luci.20150428.0067-0078
  • 09:10 thin cirrus, seeing 0.8
  • 09: 25 almost all the sky is covered by the cirrus, images from 0073 could have the fainter spectrum than the other. seeing 0.53
  • 09:35 now the sky is clear, seeing 0.61
  • 09:40 seeing 0.55
  • the image 0077 maybe not good for clouds.

10:30 slew to Piconcelli program, target A6
  • executeLUCIScript.sh A6_LS_Ks.acq luci.20150428.0079-0082
  • executeLUCIScript.sh A6_LS_Ks.spec luci.20150428.0083-0085
  • seeing variable between 1.0 and 2.0

11:12 slew to standard *executeLUCIScript.sh tellA6_LS_JHeI.acq luci.20150428.0086-0088
  • executeLUCIScrip.sh tellA6_LS_Ks.spec luci.20150428.0089-0090

-- %USERSIG{RobertaCarini - 2015-04-28}%

Comments

 
Topic revision: r8 - 20 Jun 2015, RobertaCarini
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback