At the sunset the sky is mostly cloudy, humidity 95.8%

Night duration (12\xB0 el twilight) 20:00-04:30 (3:00-11.30 UT) = 8 hrs 30 m

Observing time: 0 hrs

Weather time loss: 8.5 hrs (100%)

Data Summary

At the sunset the sky is mostly cloudy, humidity 95.8%.
3:45 the sky is mostly clear but the humidity is too high, we wait until decreases up to 90% to open.
4:52 the humidity is at 93%
5:47 the humidity rises up to 95%, the sky is totaly covered by clouds

Project_RUN Objects Filter ExpTime Notes
MODS Calibration

Details

4:19 start the calibrations for Fiore B program with MODS
  • execMODS goodsnorth2_mos_arcflat.cal (flat field + lamp) mods1b.20150425.0002-0006, mods1r.20150425.0002-0006
  • doBias mods1b.20150425.0007-0016, mods1r.20150425.0007-0016
  • flat standard dual grating execMODS slitflat_5ac.cal mods1b.20150425.0017-0022, mods1r.20150425.0017-19
  • flat standard red grating mods1r.20150425.0020-0022
  • flat standard blue grating mods1b.20150425.0023-0028, mods1b.20150425.0026-0028 are saturated, we take again the images with a lower time exposure (2 s) mods1b.20150425.0029-0032 not good mods1b.20150425.0033-0035 finally good!
  • slitless flat, dual grating mods1b.20150425.0036-0040, mods1r.20150425.0023-0027
  • slitless flat, red grating mods1r.20150425.0028-0032
  • slitless flat, blue grating mods1b.20150425.0041-0055
  • execMODS grlamps.cal (lamps dual grating) mods1r.20150425.0033-35, mods1b.20150425.0056-0058
  • lamps red grating mods1r.20150425.0036-0038
  • lamps blue grating mods1b.20150425.0059-0061
  • calibration Mignoli Program MOs21, execMODS mods.21..cal mods1r.20150425.0039-0042
  • execMODS mods.23..cal mods1r.20150425.0043-0046
  • calibration Lardo program, M12
  • execMODS mods.8.M12.cal mods1b.20150425.0062-0066
  • M13 execMODS mods.14.M13.cal mods1b.20150425.0067-0071
  • M92 execMODS mods.16.M92.cal mods1b.20150425.0072-0077
  • M3 execMODS mods.15.M3.cal mods1b.20150425.0078-0081
  • calibration Israel program A7 execMDS catsj193435_ls_flat.cal mods1b.20150425.0082-86,mods1r.20150425.0047-51
  • execMODS catsj193535_ls_arc.cal mods1b.20150425.0087,mods1r.20150425.0052
  • calibration Sommariva Program NGC 4579, execMODS NGC4579_mods.cal mods1b.20150425.0088-0092,mods1r.20150425.0053-0057