INAF LBC+MODS queue observing, 2011 November 25-26

Observer: K. Boutsia, M. Fumana
Telescope Operator: D. Gonzales-Huerta
Support Astronomer: O. Kuhn
Instrument: LBC+MODS

Summary

DOME CLOSED because of ice on the roof and high winds

Data Summary

Project Objects Filter ExpTime Notes
         

Details

Since we are closed, we decided to obtain all necessary calibrations for the projects using MODS
  • execMODS allbias.cal mods1b/mods1r 0001-0031
  • execMODS gmosflatsLBTb1.cal - flats with Donnarumma mask ID544836 mods1r 0032-0036 with ND1.5 repeat
  • execMODS grlampsb1.cal - ARCS with Donnarumma mask ID544836 mods1r 0037-0038
  • execMODS grlampsb2.cal - ARCS with Donnarumma mask ID544510 mods1r 0039-0040
  • execMODS gmosflatsLBTb2.cal - flats with Donnarumma maks ID544510 mods1r 0041-0045 with ND1.5 repeat
  • execMODS grslitflatLBT.cal - flats with LS60x5 - 8sec mods1r 0046-0050 with ND1.5 repeat
  • execMODS grslitflatLBTlongerexp.cal - flats with LS60x5 - 15sec - 15000ADU mods1r 0051-0053 with ND1.5
  • execMODS grslitflatLBTlongerexp.cal - flats with LS60x5 - 20sec - 35000ADU mods1r 0054-0058 with ND1.5
  • execMODS grslitflatLBTintensity10.cal - flats with LS60x5 - 10sec - vflat10 - 50000ADU mods1r 0059 with ND1.5
  • execMODS grslitflatLBTintensity10.cal - flats with LS60x5 - 7sec - vflat10 - 35000ADU mods1r 0061 with ND1.5
  • execMODS standard_grlamps.cal - ARCS with LS60x5 mods1r 0062-0063
  • execMODS grlamps5.0.cal - ARCS with LS60x5 for both channels using template script mod1r 0064-0066/ mod1b 0032-0034
  • execMODS grlamps1.0.ca l- ARCS with LS5x60x1.0 for both channels using template script mod1r 0067-0069/ mod1b 0035-0037
  • execMODS SlitFlatLBT.cal - flats with LS60x5 for both channels using template script mod1r 0070 / mod1b 0038 SATURATED!
  • execMODS SlitFlatLBT5.0.cal - flats with LS60x5 for both channels using template script mod1r 0071-0075 / mod1b 0039-0043 good counts (clear - GG495)
  • execMODS SlitFlatLBT1.0.cal - flats with LS5x60x1.0 for both channels using template script mod1r 0077-0081 / mod1b 0045-0049 good counts (clear - GG495)
  • execMODS SlitLESSFlat.cal - slitless flats for pixel to pixel response - we used template script mod1r 0108-0112/ mod1b 0060-0069

Donnarumma MOS flats again with GG495
  • execMODS gmosflatsLBTb1.cal - vflat 5 - exptime 10sec - some slits seem saturated mods1r 0093-0097
  • execMODS gmosflatsLBTb1.cal - vflat 5 - exptime 7sec - seems better mods1r 0098-0102
  • execMODS gmosflatsLBTb2.cal - vflat 5 - exptime 7sec mods1r 0103-0107

Nonino MOS calibrations
  • execMODS gmosFlatNonino0647.cal - flats with mask ID520958 vflat 7 mods1r 0114-0119 / mods1b 0072-0076 (clear - GG495)
  • execMODS gmosARCNonino0647.cal - ARCS with mask ID520958 mods1r 0120-0122 / mods1b 0077-0079
  • execMODS gmosARCNonino0717.cal - ARCS with mask ID532613 mods1r 0123-0125 / mods1b 0080-0082
  • execMODS gmosFlatNonino0717.cal - flats with mask ID532613 vflat 7 mods1r 0126-0130 / mods1b 0083-0087 (clear - GG495)

-- KonstantinaBoutsia - 26 Nov 2011
Topic revision: r5 - 26 Nov 2011, KonstantinaBoutsia
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback