List of images used to measure filter focus offsets

Red on left and Blue on right. I used only chip2 (but images were with all 4 chips) and usually the region at the center or above, near the rotator center. Results of dofpia are shown for the last, collimated, pupil image obtained before going on to the focus sequence. OBs are in /home/LBTO/Calib_OBs/SUPERFOC and I edited some during the run to center the focus range around best focus.

File is rb_notes in /home/LBTO/kuhn/20090320

fpia - 071320 355 -49 -78 263 -72 -58 y 0.60 0.21 /Repository/lbcr.20090320.071320.fits r-SLOAN lbcr.20090320.071630.fits[LBCCHIP2] RB_RV_superfoc R-BESSEL 7803654183 lbcb.20090320.071628.fits[LBCCHIP2] RB_RV_superfoc V-BESSEL 7803654183 lbcr.20090320.071710.fits[LBCCHIP2] RB_RV_superfoc R-BESSEL 7803654183 lbcb.20090320.071712.fits[LBCCHIP2] RB_RV_superfoc V-BESSEL 7803654183 lbcr.20090320.071750.fits[LBCCHIP2] RB_RV_superfoc R-BESSEL 7803654183 lbcb.20090320.071754.fits[LBCCHIP2] RB_RV_superfoc V-BESSEL 7803654183 lbcr.20090320.071831.fits[LBCCHIP2] RB_RV_superfoc R-BESSEL 7803654183 lbcb.20090320.071836.fits[LBCCHIP2] RB_RV_superfoc V-BESSEL 7803654183 lbcr.20090320.071911.fits[LBCCHIP2] RB_RV_superfoc R-BESSEL 7803654183 lbcb.20090320.071919.fits[LBCCHIP2] RB_RV_superfoc V-BESSEL 7803654183

fpia - 071911 output?? lbcr.20090320.073807.fits[LBCCHIP2] RB_rV_superfoc r-SLOAN 7803654371 lbcb.20090320.073808.fits[LBCCHIP2] RB_rV_superfoc V-BESSEL 7803654371 lbcr.20090320.073848.fits[LBCCHIP2] RB_rV_superfoc r-SLOAN 7803654371 lbcb.20090320.073852.fits[LBCCHIP2] RB_rV_superfoc V-BESSEL 7803654371 lbcr.20090320.073929.fits[LBCCHIP2] RB_rV_superfoc r-SLOAN 7803654371 lbcb.20090320.073934.fits[LBCCHIP2] RB_rV_superfoc V-BESSEL 7803654371 lbcr.20090320.074011.fits[LBCCHIP2] RB_rV_superfoc r-SLOAN 7803654371 lbcb.20090320.074018.fits[LBCCHIP2] RB_rV_superfoc V-BESSEL 7803654371 lbcr.20090320.074052.fits[LBCCHIP2] RB_rV_superfoc r-SLOAN 7803654371 lbcb.20090320.074101.fits[LBCCHIP2] RB_rV_superfoc V-BESSEL 7803654371

fpia - 075519 -257 -261 173 -9 49 -102 y 0.48 0.17 /Repository/lbcr.20090320.075519.fits r-SLOAN lbcr.20090320.075738.fits[LBCCHIP2] RB_rV_superfoc r-SLOAN 7803654541 lbcb.20090320.075738.fits[LBCCHIP2] RB_rV_superfoc V-BESSEL 7803654541 lbcr.20090320.075819.fits[LBCCHIP2] RB_rV_superfoc r-SLOAN 7803654541 lbcb.20090320.075822.fits[LBCCHIP2] RB_rV_superfoc V-BESSEL 7803654541 lbcr.20090320.075859.fits[LBCCHIP2] RB_rV_superfoc r-SLOAN 7803654541 lbcb.20090320.075906.fits[LBCCHIP2] RB_rV_superfoc V-BESSEL 7803654541 lbcr.20090320.075941.fits[LBCCHIP2] RB_rV_superfoc r-SLOAN 7803654541 lbcb.20090320.075950.fits[LBCCHIP2] RB_rV_superfoc V-BESSEL 7803654541 lbcr.20090320.080022.fits[LBCCHIP2] RB_rV_superfoc r-SLOAN 7803654541 lbcb.20090320.080032.fits[LBCCHIP2] RB_rV_superfoc V-BESSEL 7803654541

lbcr.20090320.080245.fits[LBCCHIP2] RB_Ir_superfoc I-BESSEL 7803654931 lbcb.20090320.080246.fits[LBCCHIP2] RB_Ir_superfoc r-SLOAN 7803654931 lbcr.20090320.080326.fits[LBCCHIP2] RB_Ir_superfoc I-BESSEL 7803654931 lbcb.20090320.080330.fits[LBCCHIP2] RB_Ir_superfoc r-SLOAN 7803654931 lbcr.20090320.080406.fits[LBCCHIP2] RB_Ir_superfoc I-BESSEL 7803654931 lbcb.20090320.080413.fits[LBCCHIP2] RB_Ir_superfoc r-SLOAN 7803654931 lbcr.20090320.080448.fits[LBCCHIP2] RB_Ir_superfoc I-BESSEL 7803654931 lbcb.20090320.080457.fits[LBCCHIP2] RB_Ir_superfoc r-SLOAN 7803654931 lbcr.20090320.080527.fits[LBCCHIP2] RB_Ir_superfoc I-BESSEL 7803654931 lbcb.20090320.080540.fits[LBCCHIP2] RB_Ir_superfoc r-SLOAN 7803654931 lbcr.20090320.080608.fits[LBCCHIP2] RB_Ir_superfoc I-BESSEL 7803654931 lbcb.20090320.080622.fits[LBCCHIP2] RB_Ir_superfoc r-SLOAN 7803654931

fpia - 081238 -335 -99 30 41 -26 -60 y 0.46 0.16 /Repository/lbcr.20090320.081238.fits r-SLOAN lbcr.20090320.081509.fits[LBCCHIP2] RB_RUs_superfoc R-BESSEL 7803655036 lbcb.20090320.081513.fits[LBCCHIP2] RB_RUs_superfoc SDT_Uspe 7803655036 lbcr.20090320.081548.fits[LBCCHIP2] RB_RUs_superfoc R-BESSEL 7803655036 lbcb.20090320.081557.fits[LBCCHIP2] RB_RUs_superfoc SDT_Uspe 7803655036 lbcr.20090320.081630.fits[LBCCHIP2] RB_RUs_superfoc R-BESSEL 7803655036 lbcb.20090320.081640.fits[LBCCHIP2] RB_RUs_superfoc SDT_Uspe 7803655036 lbcr.20090320.081712.fits[LBCCHIP2] RB_RUs_superfoc R-BESSEL 7803655036 lbcb.20090320.081724.fits[LBCCHIP2] RB_RUs_superfoc SDT_Uspe 7803655036 lbcr.20090320.081752.fits[LBCCHIP2] RB_RUs_superfoc R-BESSEL 7803655036 lbcb.20090320.081806.fits[LBCCHIP2] RB_RUs_superfoc SDT_Uspe 7803655036

lbcr.20090320.082118.fits[LBCCHIP2] RB_RUs_superfoc R-BESSEL 7803655089 lbcb.20090320.082118.fits[LBCCHIP2] RB_RUs_superfoc SDT_Uspe 7803655089 lbcr.20090320.082158.fits[LBCCHIP2] RB_RUs_superfoc R-BESSEL 7803655089 lbcb.20090320.082202.fits[LBCCHIP2] RB_RUs_superfoc SDT_Uspe 7803655089 lbcr.20090320.082239.fits[LBCCHIP2] RB_RUs_superfoc R-BESSEL 7803655089 lbcb.20090320.082245.fits[LBCCHIP2] RB_RUs_superfoc SDT_Uspe 7803655089 lbcr.20090320.082320.fits[LBCCHIP2] RB_RUs_superfoc R-BESSEL 7803655089 lbcb.20090320.082328.fits[LBCCHIP2] RB_RUs_superfoc SDT_Uspe 7803655089 lbcr.20090320.082401.fits[LBCCHIP2] RB_RUs_superfoc R-BESSEL 7803655089 lbcb.20090320.082410.fits[LBCCHIP2] RB_RUs_superfoc SDT_Uspe 7803655089

fpia - 082833 205 144 163 20 60 -145 y 0.40 0.16 /Repository/lbcr.20090320.082833.fits r-SLOAN lbcr.20090320.083107.fits[LBCCHIP2] RB_ig_superfoc i-SLOAN 7803655175 lbcb.20090320.083111.fits[LBCCHIP2] RB_ig_superfoc g-SLOAN 7803655175 lbcr.20090320.083148.fits[LBCCHIP2] RB_ig_superfoc i-SLOAN 7803655175 lbcb.20090320.083155.fits[LBCCHIP2] RB_ig_superfoc g-SLOAN 7803655175 lbcr.20090320.083229.fits[LBCCHIP2] RB_ig_superfoc i-SLOAN 7803655175 lbcb.20090320.083237.fits[LBCCHIP2] RB_ig_superfoc g-SLOAN 7803655175 lbcr.20090320.083309.fits[LBCCHIP2] RB_ig_superfoc i-SLOAN 7803655175 lbcb.20090320.083320.fits[LBCCHIP2] RB_ig_superfoc g-SLOAN 7803655175 lbcr.20090320.083349.fits[LBCCHIP2] RB_ig_superfoc i-SLOAN 7803655175 lbcb.20090320.083428.fits[LBCCHIP2] RB_ig_superfoc g-SLOAN 7803655175

lbcr.20090320.083611.fits[LBCCHIP2] RB_zB_superfoc z-SLOAN 7803655218 lbcb.20090320.083614.fits[LBCCHIP2] RB_zB_superfoc B-BESSEL 7803655218 lbcr.20090320.083652.fits[LBCCHIP2] RB_zB_superfoc z-SLOAN 7803655218 lbcb.20090320.083658.fits[LBCCHIP2] RB_zB_superfoc B-BESSEL 7803655218 lbcr.20090320.083731.fits[LBCCHIP2] RB_zB_superfoc z-SLOAN 7803655218 lbcb.20090320.083742.fits[LBCCHIP2] RB_zB_superfoc B-BESSEL 7803655218 lbcr.20090320.083812.fits[LBCCHIP2] RB_zB_superfoc z-SLOAN 7803655218 lbcb.20090320.083824.fits[LBCCHIP2] RB_zB_superfoc B-BESSEL 7803655218 lbcr.20090320.083853.fits[LBCCHIP2] RB_zB_superfoc z-SLOAN 7803655218 lbcb.20090320.083908.fits[LBCCHIP2] RB_zB_superfoc B-BESSEL 7803655218

lbcr.20090320.084134.fits[LBCCHIP2] RB_Ir_superfoc I-BESSEL 7803655267 lbcb.20090320.084134.fits[LBCCHIP2] RB_Ir_superfoc r-SLOAN 7803655267 lbcr.20090320.084215.fits[LBCCHIP2] RB_Ir_superfoc I-BESSEL 7803655267 lbcb.20090320.084218.fits[LBCCHIP2] RB_Ir_superfoc r-SLOAN 7803655267 lbcr.20090320.084256.fits[LBCCHIP2] RB_Ir_superfoc I-BESSEL 7803655267 lbcb.20090320.084302.fits[LBCCHIP2] RB_Ir_superfoc r-SLOAN 7803655267 lbcr.20090320.084336.fits[LBCCHIP2] RB_Ir_superfoc I-BESSEL 7803655267 lbcb.20090320.084346.fits[LBCCHIP2] RB_Ir_superfoc r-SLOAN 7803655267 lbcr.20090320.084417.fits[LBCCHIP2] RB_Ir_superfoc I-BESSEL 7803655267 lbcb.20090320.084428.fits[LBCCHIP2] RB_Ir_superfoc r-SLOAN 7803655267 lbcr.20090320.084457.fits[LBCCHIP2] RB_Ir_superfoc I-BESSEL 7803655267 lbcb.20090320.084512.fits[LBCCHIP2] RB_Ir_superfoc r-SLOAN 7803655267

fpia - 084951 206 105 70 -284 -97 -64 y 0.39 0.18 /Repository/lbcr.20090320.084951.fits r-SLOAN lbcr.20090320.085230.fits[LBCCHIP2] RB_Ir_superfoc I-BESSEL 7803655357 lbcb.20090320.085232.fits[LBCCHIP2] RB_Ir_superfoc r-SLOAN 7803655357 lbcr.20090320.085309.fits[LBCCHIP2] RB_Ir_superfoc I-BESSEL 7803655357 lbcb.20090320.085316.fits[LBCCHIP2] RB_Ir_superfoc r-SLOAN 7803655357 lbcr.20090320.085350.fits[LBCCHIP2] RB_Ir_superfoc I-BESSEL 7803655357 lbcb.20090320.085358.fits[LBCCHIP2] RB_Ir_superfoc r-SLOAN 7803655357 lbcr.20090320.085430.fits[LBCCHIP2] RB_Ir_superfoc I-BESSEL 7803655357 lbcb.20090320.085440.fits[LBCCHIP2] RB_Ir_superfoc r-SLOAN 7803655357 lbcr.20090320.085510.fits[LBCCHIP2] RB_Ir_superfoc I-BESSEL 7803655357 lbcb.20090320.085524.fits[LBCCHIP2] RB_Ir_superfoc r-SLOAN 7803655357 lbcr.20090320.085551.fits[LBCCHIP2] RB_Ir_superfoc I-BESSEL 7803655357 lbcb.20090320.085608.fits[LBCCHIP2] RB_Ir_superfoc r-SLOAN 7803655357

lbcr.20090320.085759.fits[LBCCHIP2] RB_YU_superfoc Y-FAN 7803655407 lbcb.20090320.085759.fits[LBCCHIP2] RB_YU_superfoc U-BESSEL 7803655407 lbcr.20090320.085840.fits[LBCCHIP2] RB_YU_superfoc Y-FAN 7803655407 lbcb.20090320.085843.fits[LBCCHIP2] RB_YU_superfoc U-BESSEL 7803655407 lbcr.20090320.085920.fits[LBCCHIP2] RB_YU_superfoc Y-FAN 7803655407 lbcb.20090320.085926.fits[LBCCHIP2] RB_YU_superfoc U-BESSEL 7803655407 lbcr.20090320.090001.fits[LBCCHIP2] RB_YU_superfoc Y-FAN 7803655407 lbcb.20090320.090008.fits[LBCCHIP2] RB_YU_superfoc U-BESSEL 7803655407 lbcr.20090320.090042.fits[LBCCHIP2] RB_YU_superfoc Y-FAN 7803655407 lbcb.20090320.090051.fits[LBCCHIP2] RB_YU_superfoc U-BESSEL 7803655407

lbcr.20090320.090327.fits[LBCCHIP2] R_F972-004mm_super F972N20 7803655798 lbcr.20090320.090410.fits[LBCCHIP2] R_F972-004mm_super F972N20 7803655798 lbcr.20090320.090454.fits[LBCCHIP2] R_F972-004mm_super F972N20 7803655798 lbcr.20090320.090538.fits[LBCCHIP2] R_F972-004mm_super F972N20 7803655798 lbcr.20090320.090622.fits[LBCCHIP2] R_F972-004mm_super F972N20 7803655798

fpia - 091126 360 64 54 -302 54 -53 y 0.38 0.22 /Repository/lbcr.20090320.091126.fits r-SLOAN lbcr.20090320.091815.fits[LBCCHIP2] RB_YU_superfoc Y-FAN 7803655926 lbcb.20090320.091823.fits[LBCCHIP2] RB_YU_superfoc U-BESSEL 7803655926 lbcr.20090320.091855.fits[LBCCHIP2] RB_YU_superfoc Y-FAN 7803655926 lbcb.20090320.091907.fits[LBCCHIP2] RB_YU_superfoc U-BESSEL 7803655926 lbcr.20090320.091936.fits[LBCCHIP2] RB_YU_superfoc Y-FAN 7803655926 lbcb.20090320.091949.fits[LBCCHIP2] RB_YU_superfoc U-BESSEL 7803655926 lbcr.20090320.092017.fits[LBCCHIP2] RB_YU_superfoc Y-FAN 7803655926 lbcb.20090320.092032.fits[LBCCHIP2] RB_YU_superfoc U-BESSEL 7803655926 lbcr.20090320.092058.fits[LBCCHIP2] RB_YU_superfoc Y-FAN 7803655926 lbcb.20090320.092114.fits[LBCCHIP2] RB_YU_superfoc U-BESSEL 7803655926

lbcr.20090320.092427.fits[LBCCHIP2] RB_zB_superfoc z-SLOAN 7803655980 lbcb.20090320.092426.fits[LBCCHIP2] RB_zB_superfoc B-BESSEL 7803655980 lbcr.20090320.092508.fits[LBCCHIP2] RB_zB_superfoc z-SLOAN 7803655980 lbcb.20090320.092537.fits[LBCCHIP2] RB_zB_superfoc B-BESSEL 7803655980 lbcr.20090320.092549.fits[LBCCHIP2] RB_zB_superfoc z-SLOAN 7803655980 lbcb.20090320.092621.fits[LBCCHIP2] RB_zB_superfoc B-BESSEL 7803655980 lbcr.20090320.092630.fits[LBCCHIP2] RB_zB_superfoc z-SLOAN 7803655980 lbcb.20090320.092705.fits[LBCCHIP2] RB_zB_superfoc B-BESSEL 7803655980 lbcr.20090320.092711.fits[LBCCHIP2] RB_zB_superfoc z-SLOAN 7803655980 lbcb.20090320.092747.fits[LBCCHIP2] RB_zB_superfoc B-BESSEL 7803655980

lbcr.20090320.092916.fits[LBCCHIP2] R_F972-004mm_super F972N20 7803656022 lbcr.20090320.092958.fits[LBCCHIP2] R_F972-004mm_super F972N20 7803656022 lbcr.20090320.093043.fits[LBCCHIP2] R_F972-004mm_super F972N20 7803656022 lbcr.20090320.093128.fits[LBCCHIP2] R_F972-004mm_super F972N20 7803656022 lbcr.20090320.093212.fits[LBCCHIP2] R_F972-004mm_super F972N20 7803656022

fpia - 094450 35 -164 117 -56 216 -141 y 0.41 0.17 /Repository/lbcr.20090320.094450.fits r-SLOAN lbcr.20090320.094716.fits[LBCCHIP2] RB_ig_superfoc i-SLOAN 7803656177 lbcb.20090320.094718.fits[LBCCHIP2] RB_ig_superfoc g-SLOAN 7803656177 lbcr.20090320.094755.fits[LBCCHIP2] RB_ig_superfoc i-SLOAN 7803656177 lbcb.20090320.094802.fits[LBCCHIP2] RB_ig_superfoc g-SLOAN 7803656177 lbcr.20090320.094837.fits[LBCCHIP2] RB_ig_superfoc i-SLOAN 7803656177 lbcb.20090320.094846.fits[LBCCHIP2] RB_ig_superfoc g-SLOAN 7803656177 lbcr.20090320.094918.fits[LBCCHIP2] RB_ig_superfoc i-SLOAN 7803656177 lbcb.20090320.094928.fits[LBCCHIP2] RB_ig_superfoc g-SLOAN 7803656177 lbcr.20090320.094957.fits[LBCCHIP2] RB_ig_superfoc i-SLOAN 7803656177 lbcb.20090320.095012.fits[LBCCHIP2] RB_ig_superfoc g-SLOAN 7803656177

fpia - 100340 -276 -93 86 -172 47 6 y 0.35 0.16 /Repository/lbcr.20090320.100340.fits r-SLOAN lbcr.20090320.100603.fits[LBCCHIP2] RB_ig_superfoc i-SLOAN 7803656686 lbcb.20090320.100605.fits[LBCCHIP2] RB_ig_superfoc g-SLOAN 7803656686 lbcr.20090320.100643.fits[LBCCHIP2] RB_ig_superfoc i-SLOAN 7803656686 lbcb.20090320.100649.fits[LBCCHIP2] RB_ig_superfoc g-SLOAN 7803656686 lbcr.20090320.100726.fits[LBCCHIP2] RB_ig_superfoc i-SLOAN 7803656686 lbcb.20090320.100734.fits[LBCCHIP2] RB_ig_superfoc g-SLOAN 7803656686 lbcr.20090320.100807.fits[LBCCHIP2] RB_ig_superfoc i-SLOAN 7803656686 lbcb.20090320.100818.fits[LBCCHIP2] RB_ig_superfoc g-SLOAN 7803656686 lbcr.20090320.100847.fits[LBCCHIP2] RB_ig_superfoc i-SLOAN 7803656686 lbcb.20090320.100901.fits[LBCCHIP2] RB_ig_superfoc g-SLOAN 7803656686

lbcr.20090320.101136.fits[LBCCHIP2] RB_VV_superfoc V-BESSEL 7803656736 lbcb.20090320.101138.fits[LBCCHIP2] RB_VV_superfoc V-BESSEL 7803656736 lbcr.20090320.101215.fits[LBCCHIP2] RB_VV_superfoc V-BESSEL 7803656736 lbcb.20090320.101222.fits[LBCCHIP2] RB_VV_superfoc V-BESSEL 7803656736 lbcr.20090320.101257.fits[LBCCHIP2] RB_VV_superfoc V-BESSEL 7803656736 lbcb.20090320.101305.fits[LBCCHIP2] RB_VV_superfoc V-BESSEL 7803656736 lbcr.20090320.101338.fits[LBCCHIP2] RB_VV_superfoc V-BESSEL 7803656736 lbcb.20090320.101347.fits[LBCCHIP2] RB_VV_superfoc V-BESSEL 7803656736 lbcr.20090320.101420.fits[LBCCHIP2] RB_VV_superfoc V-BESSEL 7803656736 lbcb.20090320.101431.fits[LBCCHIP2] RB_VV_superfoc V-BESSEL 7803656736

lbcr.20090320.101724.fits[LBCCHIP2] RB_RUs_superfoc R-BESSEL 7803656783 lbcb.20090320.101721.fits[LBCCHIP2] RB_RUs_superfoc SDT_Uspe 7803656783 lbcr.20090320.101804.fits[LBCCHIP2] RB_RUs_superfoc R-BESSEL 7803656783 lbcb.20090320.101805.fits[LBCCHIP2] RB_RUs_superfoc SDT_Uspe 7803656783 lbcr.20090320.101908.fits[LBCCHIP2] RB_RUs_superfoc R-BESSEL 7803656783 lbcb.20090320.101847.fits[LBCCHIP2] RB_RUs_superfoc SDT_Uspe 7803656783 lbcr.20090320.101949.fits[LBCCHIP2] RB_RUs_superfoc R-BESSEL 7803656783 lbcb.20090320.101930.fits[LBCCHIP2] RB_RUs_superfoc SDT_Uspe 7803656783 lbcr.20090320.102029.fits[LBCCHIP2] RB_RUs_superfoc R-BESSEL 7803656783 lbcb.20090320.102012.fits[LBCCHIP2] RB_RUs_superfoc SDT_Uspe 7803656783

fpia - 103343 270 139 14 -156 44 -32 y 0.37 0.16 /Repository/lbcr.20090320.103343.fits r-SLOAN lbcr.20090320.103637.fits[LBCCHIP2] RB_ig_superfoc i-SLOAN 7803656951 lbcb.20090320.103639.fits[LBCCHIP2] RB_ig_superfoc g-SLOAN 7803656951 lbcr.20090320.103716.fits[LBCCHIP2] RB_ig_superfoc i-SLOAN 7803656951 lbcb.20090320.103723.fits[LBCCHIP2] RB_ig_superfoc g-SLOAN 7803656951 lbcr.20090320.103756.fits[LBCCHIP2] RB_ig_superfoc i-SLOAN 7803656951 lbcb.20090320.103805.fits[LBCCHIP2] RB_ig_superfoc g-SLOAN 7803656951 lbcr.20090320.103900.fits[LBCCHIP2] RB_ig_superfoc i-SLOAN 7803656951 lbcb.20090320.103849.fits[LBCCHIP2] RB_ig_superfoc g-SLOAN 7803656951 lbcr.20090320.103941.fits[LBCCHIP2] RB_ig_superfoc i-SLOAN 7803656951 lbcb.20090320.103933.fits[LBCCHIP2] RB_ig_superfoc g-SLOAN 7803656951

lbcr.20090320.104226.fits[LBCCHIP2] RB_VV_superfoc V-BESSEL 7803656999 lbcb.20090320.104229.fits[LBCCHIP2] RB_VV_superfoc V-BESSEL 7803656999 lbcr.20090320.104305.fits[LBCCHIP2] RB_VV_superfoc V-BESSEL 7803656999 lbcb.20090320.104313.fits[LBCCHIP2] RB_VV_superfoc V-BESSEL 7803656999 lbcr.20090320.104348.fits[LBCCHIP2] RB_VV_superfoc V-BESSEL 7803656999 lbcb.20090320.104355.fits[LBCCHIP2] RB_VV_superfoc V-BESSEL 7803656999 lbcr.20090320.104429.fits[LBCCHIP2] RB_VV_superfoc V-BESSEL 7803656999 lbcb.20090320.104438.fits[LBCCHIP2] RB_VV_superfoc V-BESSEL 7803656999 lbcr.20090320.104510.fits[LBCCHIP2] RB_VV_superfoc V-BESSEL 7803656999 lbcb.20090320.104520.fits[LBCCHIP2] RB_VV_superfoc V-BESSEL 7803656999

fpia - 105123 54 266 -141 -14 -109 -111 y 0.35 0.15 /Repository/lbcr.20090320.105123.fits r-SLOAN lbcr.20090320.105409.fits[LBCCHIP2] RB_Ir_superfoc I-BESSEL 7803657102 lbcb.20090320.105413.fits[LBCCHIP2] RB_Ir_superfoc r-SLOAN 7803657102 lbcr.20090320.105448.fits[LBCCHIP2] RB_Ir_superfoc I-BESSEL 7803657102 lbcb.20090320.105456.fits[LBCCHIP2] RB_Ir_superfoc r-SLOAN 7803657102 lbcr.20090320.105530.fits[LBCCHIP2] RB_Ir_superfoc I-BESSEL 7803657102 lbcb.20090320.105540.fits[LBCCHIP2] RB_Ir_superfoc r-SLOAN 7803657102 lbcr.20090320.105609.fits[LBCCHIP2] RB_Ir_superfoc I-BESSEL 7803657102 lbcb.20090320.105622.fits[LBCCHIP2] RB_Ir_superfoc r-SLOAN 7803657102 lbcr.20090320.105650.fits[LBCCHIP2] RB_Ir_superfoc I-BESSEL 7803657102 lbcb.20090320.105706.fits[LBCCHIP2] RB_Ir_superfoc r-SLOAN 7803657102 lbcr.20090320.105730.fits[LBCCHIP2] RB_Ir_superfoc I-BESSEL 7803657102 lbcb.20090320.105750.fits[LBCCHIP2] RB_Ir_superfoc r-SLOAN 7803657102

lbcr.20090320.105913.fits[LBCCHIP2] RB_VV_superfoc V-BESSEL 7803657145 lbcb.20090320.105908.fits[LBCCHIP2] RB_VV_superfoc V-BESSEL 7803657145 lbcr.20090320.105952.fits[LBCCHIP2] RB_VV_superfoc V-BESSEL 7803657145 lbcb.20090320.105950.fits[LBCCHIP2] RB_VV_superfoc V-BESSEL 7803657145 lbcr.20090320.110033.fits[LBCCHIP2] RB_VV_superfoc V-BESSEL 7803657145 lbcb.20090320.110032.fits[LBCCHIP2] RB_VV_superfoc V-BESSEL 7803657145 lbcr.20090320.110114.fits[LBCCHIP2] RB_VV_superfoc V-BESSEL 7803657145 lbcb.20090320.110116.fits[LBCCHIP2] RB_VV_superfoc V-BESSEL 7803657145 lbcr.20090320.110154.fits[LBCCHIP2] RB_VV_superfoc V-BESSEL 7803657145 lbcb.20090320.110158.fits[LBCCHIP2] RB_VV_superfoc V-BESSEL 7803657145

-- OlgaKuhn - 21 Mar 2009