Backlinks to LorenzoBusoni in all Webs (Search Main Web only)

No backlinks in this web

Results from ARGOS web retrieved at 17:28 (GMT)

BugsSummary
Is a goal of this topic Having a trace of every single occurred (or possibly occurred) bugs/failure in the hardware and/or software that is not fully understood ...
DayTime20140505
This snapshots were acquired by WG and DP during the CalUnitSystem alignment process. SN tag AO rec LAN focus LM1 phi LM1 piston LM1 theta LAN stat...
DayTime20141030
Servicing of LgswUnitDx Entance windows separation is 137mm (nominal is 137.9mm). This is the same distance that we have in the LgswUnitSx. So the field stop is ...
DayTime20150820
Pockels Cells Driver On sx lgsw in the /home/argos/the_pcd folder created pcd_start and pcd_stop to start/stop the PCD accordingly to JZ email of 150612 Zabbix S...
DayTime20150823
20150823_170000 LgswUnitSx is powered off. Disconnected from the rack. 20150823_180000 LgswUnitDx is completely disassembled apart for WfsCamera and lenslet...
DayTime20150824
Activity on LgswUnitDx Aligment of pupil motors Pupil motors have been shimmed to bring the stage working position closer to 0. We experienced on LgswUnitSx some...
DayTime20150825
Piezo mirrors alignment Alignment of periscopes. The flange has been remachined at LBT for the new periscope mirrors holders. Gola is to get the beam after the pe...
DayTime201812016
UT 00:45 opening up the telescope.UT 01:20 getting telescope collimated UT 02:08 time of flight didn't know KL_v26had to change ngs_truth_sensor.py What a dirty h...
DayTime201812018
The Fog prevented early start. UT 08:26 Opening telescope Heater is not working properly.Beam focus is running away over time. Main.LorenzoBusoni 19 Jan 2019
DayTime20200310
Setup Remember to configure AdSec for UAO (that means it accepts 1600 slopes as it was in the good old days). Now the default is for SOUL with 2400 slopes Doug kn...
DayTime20200609
ARGOS daytime testing 2020 06 09 Participants: Lorenzo B., Marco B., Wolfgang G., Gustavo R., Carl H., Shane W. Setup AdSec set up for UAO (default is SOUL): 1) ...
DiaryRun18
LUCI1 MOS is broken, we can use LUCI1 only for imaging. In the last weeks the LBT AO team has prepared the SW and calibrations for the TTOffset compensation LUT, ...
DiaryRun23
There are issues with the SX. Why? When What Log Notes 20200310 SX Remote Daytime DayTime20200310 20200609 SX Remote Daytime DayTime2020...
EngPanel
LBT EngPanel LBT EngPanel is a tool developed by Microgate to configure and connect to a BCU unit. The attached software runs on Windows machines, and require the...
FastGuiding
Tricks for calibration on sky * Loop Closed on a bright NGS star with FLAO only 36 modes to keep proper collimation * VibrationCompensation ON * Optimise...
r4 - 01 May 2017 - 08:26 by TommasoMazzoni
HowToAcquireFramesWithPatrolCameraAtFullSpeed
Howto Acquire Frames With Patrol Camera At Full Speed Data acquired using tools in: argos@sx lgsw x64 $ pwd /home/argos/Downloads/AVTCam/AVT GigE SDK/bin pc/x64 ...
HowToAddANewModalBasis
How to Add a New Modal Basis When the ASM is re calibrated a new modal basis is created and saved in the ASM computer.We need to produce a local copy of the modal...
HowToAdjustBcuPowerSupply
* OBSOLETE: THE ARGOS BCU POWER SUPPLIES HAVE BEEN UPGRADED BY MICROGATE IN 2016 * Informations about how to read the BCU power supply voltage directly from the ...
HowToConnectToARGOSWorkstationAtLBT
The following instructions apply if you are connecting from outside the telescope network. If you are at the telescope just follow HowToLogInAndConnectToVNC Logi...
HowToDoComaFreePointingOffset
There are 2 ways to perform a "coma free" pointing offset moving the AdSec hexapod: 1. using the TCS GUI 1. using the ARGOS terminal How to perform a point...
HowToEnableDayTimeModeInTCS
How to Enable Day Time Mode in TCS Rationale When working in day time with the CalUnitSystem the TCS must be informed. If this is not done the TCS offloads the s...
HowToEnableMainPower
The ARGOS main power switches are located in the SX LaserSupplyRack on the LaserSupplyPlatform. They should be on all the time. If they are not on enable them i...
HowToMoveComaFree
2016 03 10: This is a duplicated topic of HowToDoComaFreePointingOffset Main.LorenzoBusoni 04 Nov 2014
HowToPowerCycleTheRemotePowerSwitch
Use circuit breaker F22 on the remote power front panel (most right, upper row. labeled "REMOTE POWER"). Location: Lower argos plattform, SX rack, upper half. M...
HowToPowerUpLAS
This procedure brings up the LAS system until lasers are ready to be propagated on sky i. See FullARGOSStartUpProcedure for prerequisites: chiller, main power,...
HowToRecoverArgos
How to recover ARGOS Procedure to recover from BCU crash Usual symptom: CCD Viewer does not update 1 Set LAS and LAN in simulation (Arbitrator GUI, Tab: Exper...
HowToRemoveComa
There are 2 ways to remove coma by moving the AdSec hexapod: 1 using the ARGOS terminal 1 using TCS GUI How to remove coma using the ARGOS terminal i. O...
HowToSetUpForLUCIOffsetCalibration
How to setup the ARGOS system to measure LUCI pointing offsets The principle is to measure the LUCI pointing shift during a full rotator rotation while in closed ...
HowToSetupHexapodForCalibrationUnit
This topic contains the history of best hexapod position to align the CalUnitSystem to LUCI and LGSW * X, Y, Z, Rx, Ry, Rz are the hexapod absolute position ...
HowToStartIRTC
Start up The HW is typically always on. In case you need to access it, the control PC is in the lower treehouse. i. Login as LBTO on obs x . See UsefulLoginInf...
HowToUseTheFiberSwitch
Usage of the Fastlink Fiber Switch The Fiber Switch is a device installed in the Treehouse to configure FastLink fibers for ARGOS operation. This one superseed ...
HowtoRouteFibersBetweenPiezoHeads
How to route the calibration unit fibers Routing of the calibration unit fibers is critical. If the fibers are routed in the wrong way, the piezo head cables will...
LgswChannels
Rationale In each WFS the 3 laser beams follow indipendent path (or "channels") up to the detector. This means that several devices inside the LgswUnit are instal...
NewportNSA12StepperMotors
Description These motors are used to adjust the pupil position in the LgswUnit. They are customized: the connector has been replaced with a DB9 to plug into the S...
NotableSnapshots
A collection of notable snapshots, useful for checking analyzer algorithms, producing images for presentations and so on. Tag Diary page Notes 20150502_...
r2 - 02 Nov 2015 - 15:24 by TommasoMazzoni
PockelsCellsTransmission
History of test When Where Devices Notes Test log 20140518 LBT PockelsCell2, PockelsCell3, PockelsCell4 Ozone problem discover PockelsCellTe...
ThingsThatIDontUnderstand0001
Device The BCU #1 that was first delivered to Florence (and was before in Heidelberg for SW development). It is without ADC board, and was always affected by prob...
ThingsThatIDontUnderstand0002
Device We had this issue on BCU #1 and also on BCU #2 Description Quando si configura le 2 schede HVC, qualcosa va storto e la scheda di sotto non si configura...
ThingsThatIDontUnderstand0007
Description See attached email thread: MoCon pupilMotorBlue was not responding, but it recovers when commanded through IDL? Main.LorenzoBusoni 27 Mar 2013
TroubleShoot
Troubleshoot ARGOS Troubleshoot by states More recover procedures at: HowToRecoverArgos When Symptom What to do Notes Cold start PowerOn fails, sev...
UsefulLoginInfo
Login credentials user host pwd hint argos argos dx easy one with numbers argos argos sx easy one with numbers argos dx lalas easy o...
VirtualBox
Both LGSW workstations WorkStation1, WorkStation2 have a Windows XP OS running on Oracle VM virtualbox. On Windows XP the following software is installed: * Mi...
WebStatistics
%IF{ "istopic '.DefaultWebStatistics'" then="$percentINCLUDE{$quot.DefaultWebStatistics$quot}$percent" else="$percentINCLUDE{$quot.DefaultWebStatistics$quot}$perc...
r398 - 19 Jan 2016 - 08:15 by GillesOrban
Number of topics: 43

Results from FLAO web retrieved at 17:28 (GMT)

CUDAInstallation
From http://lifeofaprogrammergeek.blogspot.com/2008/05/cuda development in ubuntu.html This guide is written to work with a fresh installation of Ubuntu 8.04.1 (H...
FLAO1LabLog20111014all
Main.LorenzoBusoni 16 Oct 2011 IDL $ more m15SKY1sec/m15SKY1sec_obs.log " " 1 of 3 1.00000 Ks pisces.20111014.0378.fits SKY " " 2 of 3 1.00...
r2 - 11 Sep 2012 - 16:48 by EnricoPinna
FLAO1LabLog20111015a
Main.LorenzoBusoni 16 Oct 2011 M15 ELEVATION 66 # Target star: 0 m15cen_a 21:29:58.3710 12:10:00.190 RADEC 2000.0 J2000 0.0 0.0 11.00 R 0.00 B_V 1.65 # Guide s...
r4 - 11 Sep 2012 - 16:48 by EnricoPinna
FLAO1LabLog20111015b
Main.LorenzoBusoni 16 Oct 2011 HR8799 Stating at 08.59 PRESET # HR8799 preset,OBJECT=HR8799,MODE=ace,GS=2,RS=0,PA= 20auto_collimatepausecamera,EXP=5,,FRAMES=1,C...
r5 - 11 Sep 2012 - 16:48 by EnricoPinna
FLAO1LabLog20111015c
Main.LorenzoBusoni 16 Oct 2011 LBTO@obs3:82 % idlIDL Version 7.0 (linux x86 m32). (c) 2007, ITT Visual Information SolutionsInstallation number: 223182.Licensed f...
r2 - 11 Sep 2012 - 16:48 by EnricoPinna
FLAO1LabLog20130914
Installazione maschera Runa e JC installano la maschera che occulta la parte centrale dello specchio (diametro 101mm) come avviene per la luce proveniente dal cie...
FLAO1LabLog20130915
Forze troppo alte Si riparte con il rec 20130914_232352 e con il disturbo da 0.8". Problemini non meglio identificati di autogain. Gain manual adjusted e stress ...
FLAO2LabLog20120920
Unreal Telescope Clock (UTC) Il telescopio ritarda: se si guarda la finestra del logging system del tcs e qualsiasi altra finestra (AOS compreso) ci si accorge ch...
FieldPointTemperatureMeas
See FieldPointSetup.doc in the attachment files. Documents, programs and files therein mentioned should be available on Obelix under /4lbt/Archivio/labHW/FieldPoi...
IRTCDarkList
some other dark images can maybe acquired and not been copied in the dark directory IRTC software has a bug that sometimes saves a wrong pixelscale in the FITS he...
InfraredTestCamera
type startirtc on OBSx pc user testcamera password xevacamera Main.LorenzoBusoni 29 Mar 2012
LVMaosimul
On 25 Jan, 2010 on aosimul: lbusoni@aosimul:~$ df h Filesystem Type Size Used Avail Use% Mounted on /dev/sda1 ext3 21G 5.8G 14G 31% / varrun ...
LabLog20100530
On Sky da 20100531_032000 GMT a 20100531_123000 GMT Puntata WREF1 10:59:27.97 40:25:48.98 HIP 53721 R=4.8 * Ricostruttore 200 modi bin 1 * 3.30? shell rip...
LabLog20100531
Summary of IRTC dark images acquired so far the list of dark images has been moved here: IRTC dark list On Sky Puntata Wref3 TrackNo RefStar Mag El Wi...
LabLog20100602
On Sky Puntata W reference3 13:20:18.95 40:09:02.0 V=5.6, R=4.9, J=3.3, H=2.8 HIP 65072 * aggiustamento del clocking e rotazione della lente di camera* *...
LabLog20100622
Wref93 14:13:54.67 37:37:34.2 R=7.0, H=4.4 Posizione del giorno LC: X= 76.2 Y= 16.6 Seeing (DIMM) 1.0" TrackNo RefStar Mag El Wind Rec bin #mod ...
LabLog20101127
Vento altino, si esita ad aprire AO1075 Troppo brillante AO1066 R=11.1 I=10.1 024000 puntato e rippato Si fa l'autogain TrackNo RefStar Mag El W...
r3 - 11 Sep 2012 - 16:48 by EnricoPinna
LogicalVolumeManager
From http://www.linux.com/feature/118645 Understanding LVM Before jumping into the details of setting up LVM, you need to familiarize yourself with LVM terminolo...
TowerTest20090610
Kalman Filter phase I. LBusoni, GAgapito, Alfio, Juan Carlos Running System ccd39. torre10. Load flat: 2009_05_18_154957 Descrizione filtri generati Filtri e r...
TowerTest20090615
Kalman Filter phase II. LBusoni, GAgapito, Juan Carlos Running System ccd39. torre10. Load flat: 2009_05_18_154957 Piano dei test 1 Test di riproducibilità e...
WReferenceStarList
Summary of reference star used during FLAO 1st on sky run The coordinates (Wref) are available in iraf/LBTtools/IRTC/Catalogs/LBTdefault.cat on LBTO@obs4 (passwd ...
r20 - 14 Jun 2011 - 11:25 by EnricoPinna
Number of topics: 21
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback