MODS1 and MODS2 Service Positions

RotatorServiceOrientations.png

rotAngle is in degrees, as set in the MCS Rotator Status dialog by the telescope operator.

MODS1 Service Positions

Position rotAngleSorted ascending Notes
Blue CCD Head Electronics Box 45°  
Slit Mask Load Hatch 105°  
Instrument Ingress Hatch 180° Ingress only when Horizon-Pointing
Normal (PA=0) 207° Normal starting position for PA=0\xB0
Instrument Install/Remove 207° Position for MODS1 install/remove
Red CCD Head Electronics Box 225°  
IEB-Red & Cable Wrap Services 285° Cable wrap end AC, Ether, & Glycol access
IUB & IEB-Blue Service 345° The main AC power switch is on the IUB
At a given rotAngle, the position being serviced is facing outward opposite the left elevation C-ring.

This gives the clearest safe access to the service ports from one of the scissors lifts.

MODS2 Service Positions

Position rotAngle Notes
Normal (PA=0) 195° Normal starting position for PA=0° (post-install est!)
Instrument Ingress Hatch 210° Ingress only when Horizon-Pointing
Slit Mask Load Hatch 285°  
IUB & IEB-Blue Service 165° The main AC power switch is on the IUB
IEB-Red Service 105°  
Power/Glycol/Fiber Service 75° At Vertex C, gives best access to cable wrap service boxes
Red CCD Head Electronics Box 45°  
Blue CCD Head Electronics Box 225°  
Instrument Install/Remove 207°  
At a given rotAngle, the position being serviced is facing outward opposite the right elevation C-ring.

This gives the clearest safe access to the service ports from one of the scissors lifts.

-- RichardPogge - 2014 Sept 15