MODS Camera Filters

Updated: 2011 Jan 15 by R. Pogge (OSU Astronomy)

Science Camera Filters are located in the red and blue cameras in 8-position selector wheels. The filters lie between the camera primary mirror and the field-flattener/dewar window.

AGw Guide Camera filters are in front of the guide camera CCD and do not affect light entering the off-axis WFS camera.

Filters may be selected by filterID (preferred) or by position number (deprecated) (e.g., "red filter r_sdss" or "red filter 2").

transmission curves etc. coming soon

MODS1

Blue Science Camera

Pos filterID Description Use Notes
1 Clear Fused Silica Clear 128x86x6mm Nr1 General Spectroscopic Filter
2 g_sdss Barr SDSS g 86x86mm Imaging
3      
4      
5 UG5 Omega UG5+FS 128x86x6mm Nr1 UV Spectral Flats and Hg(Ar) Comp Lamps
6 u_sdss Barr SDSS u 86x86mm Imaging
7 ND1.5 Omega ND1.5 128x86x6mm Nr132111 Spectral Flats and Bright Comparison Lamps
8      

Red Science Camera

Pos filterID Description Use Notes
1 Clear BK7 Clear 128x86x6mm Nr1 General Spectroscopic Filter
2 r_sdss Barr SDSS r 86x86mm Imaging
3      
4 i_sdss Barr SDSS i 86x86mm Imaging
5 GG495 JML GG495 128x86x6mm Nr1 Red-Only Spectral 2nd Order Blocker
6 z_sdss Barr SDSS z 86x86mm Imaging
7 ND1.5 Omega ND1.5 128x86x6mm Nr130605 Spectral Flats and Bright Comparison Lamps
8      

AGw Guide Camera Filters

Pos filterID Description Use Notes
1 Clear Edmund Clear Fused Silica 50x5mm General Guiding
2 F525LP Edmund 525nm Long-Pass Yellow 50x5mm Bright Moonlight or very red stars
3 B_Bessel Optec Bessel B 50x5mm Blue guide stars or UV spectra in blue-only mode
4 ND1.0 Edmund Neutral Density 1.0 50x5mm Bright Telescope Pointing Stars

MODS2

Blue Science Camera

Pos filterID Description Use Notes
1 Clear Fused Silica Clear 128x86x6mm Nr2 General Spectroscopic Filter
2 g_sdss Asahi SDSS g 86x86mm Imaging
3      
4      
5 UG5 Omega UG5+FS 128x86x6mm Nr2 UV Spectral Flats and Hg(Ar) Comp Lamps
6 u_sdss Asahi SDSS u 86x86mm Imaging
7 ND1.5 Omega ND1.5 128x86x6mm Nr...... Spectral Flats and Bright Comparison Lamps
8      

Red Science Camera

Pos filterID Description Use Note
1 Clear BK7 Clear 128x86x6mm Nr2 General Spectroscopic Filter
2 r_sdss Asahi SDSS r 86x86mm Imaging
3      
4 i_sdss Asahi SDSS i 86x86mm Imaging
5 GG495 JML GG495 128x86x6mm Nr2 Red-Only Spectral 2nd Order Blocker
6 z_sdss Asahi SDSS z 86x86mm Imaging
7 ND1.5 Omega ND1.5 128x86x6mm Nr...... Spectral Flats and Bright Comparison Lamps
8      

AGw Guide Camera Filters

Pos filterID Description Use Notes
1 Clear Edmund Clear Fused Silica 50x5mm General Guiding
2 F525LP Edmund 525nm Long-Pass Yellow 50x5mm Bright Moonlight or very red stars
3 B_Bessel Optec Bessel B 50x5mm Blue guide stars or UV spectra in blue-only mode
4 ND1.0 Edmund Neutral Density 1.0 50x5mm Bright Telescope Pointing Stars