Test TTM con AOS

PENDING 6000 h 12:04 poi RIP

TEST IRC

TEST LOOP LC with turbulence-> OK
TEST automatic gain -> OK


INTERACTION MATRIX @ 600 MODES.

DIST_CMD:20091207_165108.
INT_MATRIX: 20091207_165134.
RECONSTRUCTOR 496 MODES: 20091207_165435. BIN 1 400 Hz, 2L/D.

BIN 1 1000 hZ 2L/d. REC:_165435

Mag:8.5

_170349,_170811. Dark:_170640
Esposito_SR: aprox.87%

---------------------------------------------------------------------------------------------------------------------------------------

BIN 2 625 Hz, 3L/D. Rec:_20091105_175922

Mag:12.3
_172036,_172239., Dark:_172632(0.2 sec, 300 frames).
Gain:0.5
FQR_SR:30%
Esposito_SR:40%

_172850. ANTIDRIFT ON
Gain:0.8

FQR_SR:30%
Esposito_SR:44%.

_173601,_173848 ANTIDRIFT OFF .....USING THE GAIN OPTIMIZATION
Gain:1

FQR_SR:37%,39%
Esposito_SR:49%,45%.

BIN 2 400 Hz, 3L/D. Rec:_20091105_17592

Mag:13.4
_174732. Dark:_175430 (0.5 sec, 300 frames) USING THE GAIN OPTIMIZATION. the routine gives gain:0.74
Gain:1

FQR_SR:28%
Esposito_SR:36%

_175644,_175828
Gain:0.8
FQR_SR:29%,23%
Esposito_SR:40% ,36%

Fault: Adsec IDL controller down, after applying the gain command, the adsec didn't apply the command.
Rip the secondary.
The BCU39 down, it was necessary to reset the BCU

BIN 3 200 Hz, 6L/D. Rec:_20091124_172104

Mag:14.5
_184946,_185116 Dark:_185321(0.2 sec, 150 frames)
gain:0.8
FQR_SR:19%,16%
Esposito_SR:20% ,20% .

_185627,_185740 ANTIDRIFT ON.
gain:0.8
FQR_SR:7%,10%
Esposito_SR:17% ,17%


REFLATENED,
BIN 3, 800Hz.
Mag:13

_190543,_190650
FQR_SR:23%,24%
Esposito_SR: 27%,27%


_191116 ANTIDRIFT OFF Dark:_191427(0.2 sec,150 frames)
gain:0.8
FQR_SR:4%
Esposito_SR:13%

_192037
gain:1
FQR_SR:3%
Esposito_SR:18%

_192618,_192821 TToffloading on and off
gain:1
FQR_SR:13%,14%
Esposito_SR:20%,20%

-- EnricoPinna - 07 Dec 2009
  • 496_modes_corrected_bin1_mag85_2.PNG:
    496_modes_corrected_bin1_mag85_2.PNG
Topic revision: r4 - 08 Dec 2009, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.