W start up Ok. load configuration: irtc_v12

OSS stat up Ok.
Secondary start up. Problems with the initial set of the secondary

Hexapod position: [ 0.78,-1.720,-0.180,-192.4,36.2,0 ]

BIN 1 a vari seeign

0.6" mag 8.5

Cloop 112503
Cloop 112710
DARK 112924

0.6" open loop

cloop 113213 dark 113524
cloop 113844 dark 114116

0.6" mag 9.5
cloop 114507 dark 114116
cloop 114612 dark 114116
cloop 114929 dark 114116

1.0" mag 9.5
cloop 115236 dark 114116/115743
cloop 115343 dark 114116/115743

1.0" mag 8.5
cloop 121344 dark 115743
cloop 121509 dark 115743

0.8" mag 8.5
cloop 121344 dark 115743
cloop 121509 dark 115743

1.0" seeing limited 121734 e 121855

BIN 2

0.8" mag 10.5
cloop 124032 dark 124415
cloop 124142 dark 124415

Ci accorgiamo che la IRTC era un po' impallata dava 430K di temp.... risettiamo e ripartiamo e ora i tempi di expo sono piu' ragionevoli.

cloop 130240 dark 130647
cloop 130405 dark 130647
CHECK DEL DRIFT DEL CCD39 con mirror di fronte cloop:132309 BIN 1 200Hz readout 2500kpix/s


con lampada spenta 132516

Bin 4 lampade spenta _134121 200Hz, readout 140
_134430 550Hz,readout 335.

bin3 lampade spenta 550Hz, readout 380
_135814


H14 - H16 SOFWARE session Luca e Alfio.


USE THORLAB FILTERS. THIS REQUIRE A CHANGE IN THE SLIT FOCUS.

FILTER THORLAB POS 1. ...... POSITION Z: 44.2.

LAMP 20% FILTER THORLAP 1, 550Hz, bin 2. 15 phot/subap.

---------------------------------------------------------------------------------

BIN 2 550 hZ. 3L/d.mag:13.2


0.8", Phot:17, Mag:13.2.

_171526.
_171646.
dark irtc:_171941
----------------------------------------------------------------------------------------

1", Phot:17, Mag:13.2.
_172505.
_172647
dark irtc: _174154
-----------------------------------------------------------------------------------------

bin 2 625 Hz 3L/D.mag:12.4

0.8", Phot:34, Mag:12.4
_175642 (fer_SR:45%.)
_175751 (fer_SR:45%.)
dark irtc: _175950.

-----------------------------------------------------------------------------------------------

bin 2 625 Hz 3L/D. mag:11.5...

0.8", Phot:84, Mag:11.5
_180514 (fer_SR:41%.)
_180620 (fer_SR:45%.)
dark irtc: _181355.


bin 2 800 Hz 3L/D. mag:10.5...

0.8", Phot:166, Mag:10.5
_182615 (fer_SR:52%.)
_182729 (fer_SR:55%.)
dark irtc: _182917.(50000us)





-- JuanCarlosGuerra - 20 Nov 2009