w start up ok.

Secondary start up ok.

OSS startup ok.

fault: W message deamon fault. Restart the W

TEST CLOSE LOOP BIN 1.

.

CLOOP <20091110_104908>
_
IRTC dark = <>
IR exp = 100000us
IR n frames = 50
Bin = <1>
LoopHz = <800>
Pup = <tracking#>
Dist =<_0.8_ovfreq_1000>
Gain = <0.5>
Mod = 3 l/D
Rec = <REC_20091005_1111109>
SN = zero/....
FW1 = <600....>
FW2 =
Phot = 600 phot/subap
Staged: <OFF>
Nota = <.SR:53%...MAG:7.5.

CORRECTED THE CAMERA LENS POSITION...

CLOOP <20091110_105317>
_
IRTC dark = <>
IR exp = 100000us
IR n frames = 50
Bin = <1>
LoopHz = <800>
Pup = <tracking#>
Dist =<_0.8_ovfreq_1000>
Gain = <0.5>
Mod = 3 l/D
Rec = <REC_20091005_1111109>
SN = zero/....
FW1 = <600....>
FW2 =
Phot = 600 phot/subap
Staged: <OFF>
Nota = <.SR:60%...MAG:7.0.

CLOOP <20091110_105950>
_
IRTC dark = <>
IR exp = 100000us
IR n frames = 50
Bin = <1>
LoopHz = <1000>
Pup = <tracking#>
Dist =<_0.8_ovfreq_1000>
Gain = <0.5>
Mod = 2 l/D
Rec = <REC_20091005_1111109>
SN = zero/....
FW1 = <600....>
FW2 =
Phot = 600 phot/subap
Staged: <OFF>
Nota = <.SR:67%...MAG:7.0.

CLOOP <20091110_110157>
_
IRTC dark = <>
IR exp = 100000us
IR n frames = 50
Bin = <1>
LoopHz = <1000>
Pup = <tracking#>
Dist =<_0.8_ovfreq_1000>
Gain = <0.5>
Mod = 2 l/D
Rec = <REC_20091005_1111109>
SN = zero/....
FW1 = <600....>
FW2 =
Phot = 600 phot/subap
Staged: <OFF>
Nota = <.SR:64%...MAG:8.5.

Rec_20091110_154043........BIN 4. ....400Hz...6L/D.......35 modes

Pupils without the scatered pixels.
FOCUS:45.4 FOR BIN 4

CLOOP <20091110_155013>
_
IRTC dark = <>
IR exp = 500000us
IR n frames = 50
Bin = <4>
LoopHz = <400>
Pup = <tracking#>
Dist =<_0.8_ovfreq_1000>
Gain = <0.6>
Mod = 6 l/D
Rec = <REC_20091005_154043>
SN = zero/....
FW1 = <600....>
FW2 =
Phot = HIGH FLUX phot/subap
Staged: <OFF>
Nota = <.SR:17%...MAG:8.5 AMEBA:41%

CLOOP <20091110_155703> SATURATED.
_
IRTC dark = <>
IR exp = 500000us
IR n frames = 50
Bin = <4>
LoopHz = <400>
Pup = <tracking#>
Dist =<OFF>
Gain = <0.6>
Mod = 6 l/D
Rec = <REC_20091005_154043>
SN = zero/....
FW1 = <600....>
FW2 =
Phot = HIGH FLUX phot/subap
Staged: <OFF>
Nota = <.SR:%...MAG:8.5 AMEBA:41%

LOOP <20091110_160040> _
IRTC dark = <>
IR exp = 300000us
IR n frames = 50
Bin = <4>
LoopHz = <400>
Pup = <tracking#>
Dist =<OFF>
Gain = <0.6>
Mod = 6 l/D
Rec = <REC_20091005_154043>
SN = zero/....
FW1 = <600....>
FW2 =
Phot = HIGH FLUX phot/subap
Staged: <OFF>
Nota = <.SR:%...MAG:8.5 AMEBA:95%

LOOP <20091110_160233> _
IRTC dark = <>
IR exp = 300000us
IR n frames = 50
Bin = <4>
LoopHz = <400>
Pup = <tracking#>
Dist =<OFF>
Gain = <0.6>
Mod = 6 l/D
Rec = <REC_20091005_154043>
SN = zero/....
FW1 = <600....>
FW2 =
Phot = HIGH FLUX phot/subap
Staged: <OFF>
Nota = <.SR:16%...MAG:10.1 AMEBA:37%
CHANGE THORLAB FILTER..
POS=1. FOCUS Z=44.3

_160939 WITHOUT DISTURBANCE THE SR IS 40%, CHAGING THE FOCUS 44.3

_161021 NOT DARK.

_161210 SR 1%. GOOD.

LOOP <20091110_161534> _
IRTC dark = <>
IR exp = 50000us
IR n frames = 50
Bin = <4>
LoopHz = <400>
Pup = <tracking#>
Dist =<_0.8overfreq1000>
Gain = <0.5>
Mod = 6 l/D
Rec = <REC_20091005_154043>
SN = zero/....
FW1 = <600....>
FW2 =
Phot = LOW FLUX phot/subap
Staged: <OFF>
Nota = <.SR:%...MAG:14.2 AMEBA:21%

LOOP <20091110_161947>
_162039,_162249 _162552(long exposure 500000us ->sr 10%
)
IRTC dark = <>
IR exp = 50000us
IR n frames = 50,100
Bin = <4>
LoopHz = <200>
Pup = <tracking#>
Dist =<_0.8overfreq1000>
Gain = <0.5>
Mod = 6 l/D
Rec = <REC_20091005_154043>
SN = zero/....
FW1 = <600....>
FW2 =
Phot = LOW FLUX phot/subap
Staged: <OFF>
Nota = <.SR:3.2%...MAG:15.5 AMEBA:10%

LOOP <20091110_162945
_ 163221, _163220 _163421, _163623 THIS CAN BE USED FOR ARGOS
IRTC dark = <>
IR exp = 500000us
IR n frames = 50
Bin = <4>
LoopHz = <100>
Pup = <tracking#>
Dist =<_0.8overfreq1000>
Gain = <0.5>
Mod = 6 l/D
Rec = <REC_20091005_154043>
SN = zero/....
FW1 = <600....>
FW2 =
Phot = LOW LOW FLUX phot/subap
Staged: <OFF>
Nota = <.SR:%...MAG:16.8 AMEBA:3.5%

LOOP <20091110_163806
_
IRTC dark = <>
IR exp = 500000us
IR n frames = 50
Bin = <4>
LoopHz = <100>
Pup = <tracking#>
Dist =<_0.8overfreq1000>
Gain = <0.5>
Mod = 6 l/D
Rec = <REC_20091005_154043>
SN = zero/....
FW1 = <600....>
FW2 =
Phot = LOW LOW FLUX phot/subap
Staged: <OFF>
Nota = <.SR:%...MAG:16.8 AMEBA:%

ARGOS TEST

Phase screen con 150 modi corretti e tip-tilt libero.

REC 5 MODI: 20091110_164335 - derivato Intmat_20091110_155043 tenendo solo 5 modi.

Phasecreen seeing 1.0" x 1000 Hz ma mandato a 800 Hz per limitazioni di oversampling.

Bin=4, mod = 6 l/D.

Loop Mag Counts/subap Gain SR Hz FWHM
165049 16.7 15 0.5 17% 100 80 mas
165634 16.7 7 0.5 12% 200 100 mas
173522 17.6 7     100 100-200 mas
173218 17.6 7     100 100-200 mas

Test a mag18: non ce la fa sia a 100Hz che a 50Hz (circa 3 counts/subap, loop diverge subito).

-- JuanCarlosGuerra - 2009-11-10
Topic revision: r3 - 11 Nov 2009, AlfioPuglisi
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback