W start up. Ok.

Secondary start up. Warm up time. Secondary up at 11:10.


OSS start up. no OK
fault: rpcserver not running

test close loop. Fault: 1|Error: RefineAO failed Adopt exception: Reading shared buffer MASTDIAGN01:OPTLOOPBUF

test of the new disturbance at 0.6". bin1 3L/D 200Hz.
Secondary start to skip frames with the disturbance on. skip _recover didn't work.
CLOSE LOOP BIN 2 rec_20090929_104220, 3L/D

set: 800 Hz, phot/subap:166, NModes:153, 3L/D

CLOOP <20091015_125508>
_
IRTC dark =
200910
IR exp =200000 us
IR n frames = 50
Bin = <2>
LoopHz = <800>
Pup = <tracking#>
Dist =<0.6sec ovfreq800>
Gain = <0.5>
Mod = 3 l/D
Rec = <tracking#>
SN = zero/....
FW1 = <600....>
FW2 =
Phot = 150 phot/subap
Staged: <OFF>
Nota = <FAULT SKIPPING FRAME THE LAMPS DROPS, SR:48%
Secondary Skipping frame. skip recover didn't work.
Fault recovery didn't work, it has been seen that the communication ADAM-UDP is not working well.
The secondacry is power off and software restarted. time:14:28

CLOOP <20091015_155458>
_155542, _155710
IRTC dark =
20091015
IR exp =200000 us
IR n frames = 50
Bin = <2>
LoopHz = <800>
Pup = <tracking#>
Dist =<0.6sec ovfreq800>
Gain = <0.5>
Mod = 3 l/D
Rec = <tracking#>
SN = zero/....
FW1 = <600....>
FW2 =
Phot = 150 phot/subap
Staged: <OFF>

nota: no_disturb_applied

CLOOP <20091015_162120>
_162244 _162319 _162357 _162505
IRTC dark =
20091015
IR exp =70000 us
IR n frames = 50
Bin = <1>
LoopHz = <1000>
Pup = <tracking#>
Dist =<0.6sec ovfreq800>
Gain = <0.5>
Mod = 2 l/D
Rec = <tracking#>
SN = zero/....
FW1 = <50....>
FW2 =
Phot = 240 phot/subap
Staged: <OFF> nota: SR=65%, 50%,

CLOOP <20091015_162709>
_162941 _163041 _163145 _163217
IRTC dark =
20091015
IR exp =70000 us
IR n frames = 50
Bin = <1>
LoopHz = <1000>
Pup = <tracking#>
Dist =<1sec ovfreq1000>
Gain = <0.5>
Mod = 2 l/D
Rec = <tracking#>
SN = zero/....
FW1 = <50....>
FW2 =
Phot = 240 phot/subap
Staged: <OFF> nota: SR=67%, 50%,56%

CLOOP <20091015_165047>
_165132 _165213 _
IRTC dark =
20091015
IR exp =70000 us
IR n frames = 50
Bin = <1>
LoopHz = <1000>
Pup = <tracking#>
Dist =<1sec ovfreq1000>
Gain = <0.3>
Mod = 2 l/D
Rec = <tracking#>
SN = zero/....
FW1 = <50....>
FW2 =
Phot = 97 phot/subap
Staged: <OFF>

nota: SR= 44%,41%,56%(photo/subap:86)

CLOOP <20091015_165523>

IRTC dark =
20091015_165648
IR exp 500000 us
IR n frames = 25
Bin = <1>
LoopHz = <1000>
Pup = <tracking#>
Dist =<1sec ovfreq1000>
Gain = <0>
Mod = 2 l/D
Rec = <tracking#>
SN = zero/....
FW1 = <600....>
FW2 =
Phot = 800 phot/subap
Staged: <OFF> nota: SR

CLOOP <20091015_165731>

IRTC dark =
20091015_165648
IR exp 500000 us
IR n frames = 25
Bin = <1>
LoopHz = <1000>
Pup = <tracking#>
Dist =<0.6sec ovfreq1000>
Gain = <0>
Mod = 2 l/D
Rec = <tracking#>
SN = zero/....
FW1 = <600....>
FW2 =
Phot = 85 phot/subap
Staged: <OFF> nota:

CLOOP <20091015_170054>
_170152 _170525 (sync WS)

IRTC dark = 20091015_165648
IR exp 70000 us
IR n frames = 25
Bin = <1>
LoopHz = <1000>
Pup = <tracking#>
Dist =<0.6sec ovfreq1000>
Gain = <0.5>
Mod = 2 l/D
Rec = <tracking#>
SN = zero/....
FW1 = <600....>
FW2 =
Phot = 85 phot/subap
Staged: <OFF> nota: **SR 61%,63%,60%**

CLOOP <20091015_171206>
_171241 171315 _171424
IRTC dark = 20091015

IR exp 70000 us
IR n frames = 25
Bin = <2>
LoopHz = <800>
Pup = <tracking#>
Dist =<0.6sec ovfreq1000>
Gain = <0.5>
Mod = 3 l/D
Rec = <tracking#>
SN = zero/....
FW1 = <600....>
FW2 =
Phot = 176 phot/subap
Staged: <OFF> nota: SR
58%,54%

CLOOP <20091015_172134>
_IRTC dark = 20091015_

IR exp =500000 us
IR n frames = 25
Bin = <2>
LoopHz = <800>
Pup = <tracking#>
Dist =<1sec ovfreq1000>
Gain = <0>
Mod = 3 l/D
Rec = <tracking#>
SN = zero/....
FW1 = <600....>
FW2 =
Phot = 3000 phot/subap
Staged: <OFF>

nota:

CLOOP <20091015_172517>

172549 _172631, _172810
_IRTC dark = 20091015

IR exp 70000 us
IR n frames = 50
Bin = <2>
LoopHz = <800>
Pup = <tracking#>
Dist =<1sec ovfreq1000>
Gain = <0.5>
Mod = 3 l/D
Rec = <tracking#>
SN = zero/....
FW1 = <600....>
FW2 =
Phot = 180 phot/subap
Staged: <OFF>
nota: SR**
**38% 31%,35%

CLOOP <20091015_173119>
_173154,_173327

1_IRTC dark = 20091015

IR exp =70000 us
IR n frames = 50
Bin = <2>
LoopHz = <800>
Pup = <tracking#>
Dist =<0.6sec ovfreq1000>
Gain = <0.6>
Mod = 3 l/D
Rec = <tracking#>
SN = zero/....
FW1 = <600....>
FW2 =
Phot = 170 phot/subap
Staged: <OFF>
Nota: SR:49%,39%,52%

CLOOP <20091015_175549>
_175617,_175658,_175733,_175809

1_IRTC dark = 20091015

IR exp =70000 us
IR n frames = 50
Bin = <2>
LoopHz = <625>
Pup = <tracking#>
Dist =<0.6sec ovfreq1000>
Gain = <0.5>
Mod = 3 l/D
Rec = <tracking#>
SN = zero/....
FW1 = <50....>
FW2 =
Phot = 80 phot/subap
Staged: <OFF>

note:SR:48%,59%,-,53%,53%
STOP OBSERVING, FAULT.. ERROR rNo space leftvon device

-- JuanCarlosGuerra - 2009-10-15
Topic revision: r8 - 11 Nov 2009, AlfioPuglisi
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback