W start up.
fault : "pyarg00 |ALW| 80|2009-10-14 09:28:37.976479| MAIN > System exception: thAOApp instance has no attribute 'tv'".

Second time power on. OK
irtc START UP OK.

Secondary start up. warming up time

BOARD SET UP irtc_v8
RUNNING THE OSS SYSTEM ...... Hexapod positions: [0.504 -1.982,-0.196,-184,38,0]

test close loop bin 1 400 Hz, 3L/D.
Failed, the secondary didn't close the loop. "Message Deamon fault" MASTDIAGN01

Seond fail during atest of the close loop.
|ALW| 11373|2009-10-14 10:54:27.967041| OPTICAL-LOOP > Frequency: 400.05 Hz (1126000)
MASTDIAGN01 |INF| 11374|2009-10-14 10:54:28.179560| MAIN > ...done
MASTDIAGN01 |WAR| 11375|2009-10-14 10:54:28.181508| OPTICAL-LOOP > Wrong filotto. Frame skipped.
MASTDIAGN01 |WAR| 11376|2009-10-14 10:54:28.420336| OPTICAL-LOOP > Wrong filotto. Frame skipped.
MASTDIAGN01 |WAR| 11377|2009-10-14 10:54:28.740381| OPTICAL-LOOP > Wrong filotto. Frame skipped.
MASTDIAGN01 |WAR| 11378|2009-10-14 10:54:28.917937| OPTICAL-LOOP > Wrong filotto. Frame skipped.
MASTDIAGN01 |WAR| 11379|2009-10-14 10:54:29.237998| OPTICAL-LOOP > Wrong filotto. Frame skipped.
MASTDIAGN01 |WAR| 11380|2009-10-14 10:54:29.416755| OPTICAL-LOOP > Wrong filotto. Frame skipped.
MASTDIAGN01 |WAR| 11381|2009-10-14 10:54:29.736819| OPTICAL-LOOP > Wrong filotto. Frame skipped.
MASTDIAGN01 |WAR| 11382|2009-10-14 10:54:29.918139| OPTICAL-LOOP > Wrong filotto. Frame skipped.
MASTDIAGN01 |WAR| 11383|2009-10-14 10:54:30.238200| OPTICAL-LOOP > Wrong filotto. Frame skipped.
MASTDIAGN01 |INF| 11384|2009-10-14 10:54:30.304682| MAIN > ...done
MASTDIAGN01 |ALW| 11385|2009-10-14 10:54:30.349550| OPTICAL-LOOP > Frequency: 41.97 Hz (1126100)
MASTDIAGN01 |ALW| 11386|2009-10-14 10:54:30.596760| OPTICAL-LOOP > Frequency: 404.57 Hz (1126200)
MASTDIAGN01 |ALW| 11387|2009-10-14 10:54:30.849529| OPTICAL-LOOP > Frequency: 395.68 Hz (1126300...
............................"

CCD 39 VIEWER HAS ADDED A NEW ITEM. A PLOT OF THE SLOPES RMS

Test GOAL PERFORMANCE bin1

REC <20091005_111109>
Modal Basis:<KL>
intmatacq = <tracking#>
n modes = <400>
cutted = <#>
Note: <................>

CLOOP <20091014_122624>
IRTC dark = <20091014_135003>
IR exp =50000 us
IR n frames = #
Bin = <1>
LoopHz = <1000>
Pup = <tracking#>
Dist =<off>
Gain = <0.4>
Mod = 2 l/D
Rec = <tracking#>
SN = zero/....
FW1 = <600-700-50%....>
FW2 =
Phot = 1218 phot/subap
Staged: <OFF>
Nota = <DARK NOT SUBTRACTED SR 77%>

CLOOP <20092014_122657>
Nota = <DARK NOT SUBTRACTED SR 79%>

CLOOP <20091014_122922>
Nota = <SR 72%>

CLOOP <20091014_123140>
IRTC dark = <20091014_135003>
IR exp =# us
IR n frames = #
Bin = <1>
LoopHz = <1000>
Pup = <tracking#>
Dist =<1sec ovfreq1000>
Gain = <0.5>
Mod = 2 l/D
Rec = <tracking#>
SN = zero/....
FW1 = <600-700-50%....>
FW2 =
Phot = 213 phot/subap
Staged: <OFF>
Nota = <SR 66%>

CLOOP <20091014_123212>
Nota = <SR 61%>

CLOOP <20091014_123254>
Nota = <SR 66%>

CLOOP <20091014_123632>
IRTC dark = <tracking>
IR exp =# us
IR n frames = #
Bin = <1>
LoopHz = <1000>
Pup = <tracking#>
Dist =<1sec ovfreq1000>
Gain = <0.5>
Mod = 2 l/D
Rec = <tracking#>
SN = zero/....
FW1 = <600-700-50%....>
FW2 =
Phot = 85 phot/subap
Staged: <OFF>
Nota = <SR 56%>

CLOOP <20091014_123708>
Nota = <SR 62%>

CLOOP <20091014_123750>
Nota = <SR 56%>

Test GOAL PERFORMANCE bin2

REC <20090929_104220>
Modal Basis:<KL>
intmatacq = <tracking#>
n modes = <153>
cutted = <#>
Note: <................>

CLOOP <20091014_125629>
IRTC dark = 20091014_125922
IR exp =200000 us
IR n frames = #
Bin = <2>
LoopHz = <800>
Pup = <tracking#>
Dist =<1sec ovfreq800>
Gain = <0.6>
Mod = 3 l/D
Rec = <tracking#>
SN = zero/....
FW1 = <600-700-50%....>
FW2 =
Phot = 166 phot/subap
Staged: <OFF>
Nota = <SR 34%>

CLOOP <20091014_125702>
Nota = <SR 29%>

CLOOP <20091014_125733>
Nota = <SR 33%>

CLOOP <20091014_140833>
_140930 _141028 , _141203
IRTC dark = 20091014_125922
IR exp =200000 us
IR n frames = 50
Bin = <2>
LoopHz = <625>
Pup = <tracking#>
Dist =<1sec ovfreq800>
Gain = <0.6>
Mod = 3 l/D
Rec = <tracking#>
SN = zero/....
FW1 = <50%....>
FW2 =
Phot = 80 phot/subap
Staged: <OFF>
Nota = <aprox. SR 38%>

two SECONDARY RIP, PHOT aprox 40photns

CLOOP <20091014_151004>
151038 _151121

IRTC dark =
20091014_125922
IR exp =200000 us
IR n frames = 50
Bin = <2>
LoopHz = <625>
Pup = <tracking#>
Dist =<1sec ovfreq800>
Gain = <0.6>
Mod = 3 l/D
Rec = <tracking#>
SN = zero/....
FW1 = <50%....>
FW2 =
Phot = 45 phot/subap
Staged: <OFF>
Nota = <aprox. SR 38%, THE BEST FLAT LOADED IS :2009_09_24/flat_cloop_400modes.sav>

TEST OF THE SCRIPT FOR RUN MULTIPLE ACQUISITION.

TEST SKIPPING FRAME.

-- JuanCarlosGuerra - 2009-10-14
Topic revision: r5 - 15 Oct 2009, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.