WFS start up. Ok.

Secondary Start Up. Ok.

IRTC start up ok.

Load board setup: irtc_v7.
Load hexapod positions: [-504,1980,-221,183,-35,0]

IRTC spot position:narrow FOV () off the field.
New hexapod positions: [-504,1980,-221,184,-38,0]
Fault: the IRTC viewer is not refreshing,proxy running.

Mirror shape saved: /flat/2009_10_05/flat_cl_400modes.sav


REGISTRATION OF THE PUPILS LOOKING THE FIXED PATTERNS.

rotation of the pupil rerotator by 0.5.

saved screenshot in the desktop.
after registration, this screenshot shows the signals with a better match.
SAVED BOARD SET UP : irtc_v8.fits

DARK: 400000us irtc_cube26.
30000us irtc_cube27


INTMATACQ <20091005_105022>
Pup = <tracking#>
Dist = <113849>
Iteration = <4>
Loop speed = <400>
bin = 1
Modul =2l/d
Rec closed loop<151900>
Gain vector close loop = <0.05>


REC <20091005_111109>
Modal Basis:<KL>
intmatacq = <20091005_105022>
n modes = <400>
cutted = <1>

rec testato in cloop con gain fino a 0.7@400Hz non oscilla senza disturbo; a 0.8 oscilla vistosamente

Recuperiamo il TT e foc dell'esapodo perche' dopo poco oscillava a 0.7. Dopo la correzione richiude bene a 0.7

A 1kHz e' instabile gia' a G=0.5, stabile a 0.4

CLOOP <tracking#> best PSF@ 400 HZ
IRTC dark = <20091005_094757>
IR exp =30000 us
IR n frames =
Bin = <1>
LoopHz = <1000>
Pup = <tracking#>
Dist =<tracking# / off>
Gain = <0.7>
Mod = 2 l/D
Rec = <tracking#>
SN = zero
FW1 = <600>
FW2 =
Phot = 4500 phot/subap
Staged: <OFF>
Nota = <................>

RON test slitte off
10.6
6.1
4.1
4.5





CLOOP <_124118>
_124220
IRTC dark = <_>

IR exp =30000 us
IR n frames = 100
Bin = <1>
LoopHz = <1000>
Pup = <tracking#>
Dist =< / off>
Gain = <0.4>
Mod = 2 l/D
Rec = <tracking#>
SN = zero/....
FW1 = <700-....>
FW2 =800
Phot =2000 phot/subap
Staged: <OFF>
Nota = <................>

PROBLEM WITH THE NETWORK. LOOKING THE STATUS OF THE DEVICES ARE ON OFF.

CLOOP <_132909>
_133010
IRTC dark = <>

IR exp =30000 us
IR n frames = 100
Bin = <1>
LoopHz = <1000>
Pup = <tracking#>
Dist =<_ovfreq_1000>
Gain = <0.5>
Mod = 2 l/D
Rec = <tracking#>
SN = zero/....
FW1 = <700....>
FW2 =
Phot = 230 phot/subap
Staged: <OFF>
Nota = <................>

CLOOP <_133216>
_133249

IRTC dark = <>
IR exp =30000 us
IR n frames = 100
Bin = <1>
LoopHz = <1000>
Pup = <tracking#>
Dist =<_ovfreq_1000>
Gain = <0.5>
Mod = 2 l/D
Rec = <tracking#>
SN = zero/....
FW1 = <600....>
FW2 =
Phot = 230 phot/subap
Staged: <OFF>
Nota = <................>

SECONDARY RIP DURING A CLOSE LOOP , faultrecover option didn'tn work

irtc_v8 board set up hexapod position [-504,1983,-223,181.5,-40,0]

CLOOP <_> not saved.
_IRTC dark = <>
IR exp =30000 us
IR n frames = 100
Bin = <1>
LoopHz = <1000>
Pup = <tracking#>
Dist =<_ovfreq_1000>
Gain = <0.5>
Mod = 2 l/D
Rec = <tracking#>
SN = zero/....
FW1 = <600....>
FW2 =
Phot = aprox85 phot/subap
Staged: <OFF>
Nota = <.......skipping frame .........>
Secondary shape saved: 2009_10_05/flat_1500_400modes.sav. &
flat_1500_400modesv2.sav. This flat loaded gives RETRY

centering the pupils

CLOOP <_153130>
_153203
_IRTC dark = <dark acquire_time stamp: 15:55 _cube14>
IR exp =30000 us
IR n frames = 100
Bin = <1>
LoopHz = <1000>
Pup = <tracking#>
Dist =<_ovfreq_1000>
Gain = <0.4>
Mod = 2 l/D
Rec = <tracking#>
SN = zero/....
FW1 = <600....>
FW2 =
Phot = aprox85 phot/subap
Staged: <OFF>
Nota = <..lamp 24.
Fault: ccd39 not lived and the secondary RIP , recover fail doens't work


20091005_161451 close loop only with frames, lamp 0.
BIN 2 REC_104220 NMODES 153 800 Hz. 3L/D

CLOOP <_164935
_165044>

_IRTC dark = <irtc_cube26to acquire
IR exp =400000 us
IR n frames = 100
Bin = <2>
LoopHz = <800>
Pup = <tracking#>
Dist =<_ovfreq_800>
Gain = <0.7>
Mod = 3 l/D
Rec = <tracking#>
SN = zero/....
FW1 = <600....>
FW2 =
Phot = aprox150 phot/subap
Staged: <OFF>
Nota = <..lamp 24.

BIN 2 REC_104220 NMODES 153 625 Hz. 3L/D

CLOOP <_170248>
_170355
_IRTC dark = <irtc_cube26
IR exp =400000 us
IR n frames = 100
Bin = <2>
LoopHz = <625>
Pup = <tracking#>
Dist =<_ovfreq_625>
Gain = <0.6>
Mod = 3 l/D
Rec = <tracking#>
SN = zero/....
FW1 = <600....>
FW2 =
Phot = aprox80 phot/subap
Staged: <OFF>
Nota = <..lamp 14.

CLOOP <_173152>
_173259
_IRTC dark = <irtc_cube26
IR exp =400000 us
IR n frames = 100
Bin = <2>
LoopHz = <625>
Pup = <tracking#>
Dist =<_ovfreq_625>
Gain = <0.6>
Mod = 3 l/D
Rec = <tracking#>
SN = zero/....
FW1 = <600....>
FW2 =
Phot = aprox40 phot/subap
Staged: <OFF>
Nota = <..lamp13
BIN 2 REC_104220 NMODES 153 550 Hz. 3L/D changed to 400 Hz

CLOOP <_181234>
_181408
_IRTC dark = <irtc_cube26 _>
IR exp =400000 us
IR n frames = 100
Bin = <2>
LoopHz = <400>
Pup = <tracking#>
Dist =<_ovfreq_625>
Gain = <>
Mod = 3 l/D
Rec = <tracking#>
SN = zero/....
FW1 = <50-50....>
FW2 =
Phot = aprox 40phot/subap
Staged: <OFF>
Nota = <..lamp13 skipping frame and one subaperture shows strong.....

CLOOP <_182601>
_ 182710
_IRTC dark = <dark acquire_time stamp: _irtc_cube26>
IR exp =400000 us
IR n frames = 100
Bin = <2>
LoopHz = <400>
Pup = <tracking#>
Dist =<_ovfreq_625>
Gain = <>
Mod = 3 l/D
Rec = <tracking#>
SN = zero/....
FW1 = <50-50....>
FW2 =
Phot = aprox 35phot/subap
Staged: <OFF>
Nota = <..lamp13 skipping frame and one subaperture shows strong.....

RIP SECONDARY,..