W start up. Ok.

Secondary start up Ok.
Problem with the network, loosing communication with the secondary.

TEST OF THE REC Rec:20090930_120512 BIN 3 6L/D 66 modes.

CLOOP <tracking#> not done


Bin = <3>
LoopHz = <200>
tt:<6L/D>
Pup = <>
Dist =< _ovfreq800.0_np4000.fits/ oversampling (all frames)
Gain = <0.7>
Rec = <rec_20090930_120512>
SN = < zero
FW1 = <50-50>
FW2 = <800-40 / ..... >
Phot = <aprox 30> phot/subap
Staged: <OFF>
Nota = <lamp 12%, irtc exp time 0.7sec, dist on peak 8000..THE SECONDARY SKIP FRAME...............recenter the stage to remove the tilt in the secondary and the focus with the hexapod.
>
FAULT: CONNECTION WITH THE UMAC OF THE SECONDARY. RUNNING OSS. THINKING TO PUT IT BACK THE "EASY" IDL CONTROL OF THE HEXAPOD

CLOOP <20091002_120415>


Bin = <3>
LoopHz = <200>
tt:<6L/D>
Pup = <>
Dist =< _ovfreq625.0_np4000.fits/ oversampling (all frames)
Gain = <0.7>
Rec = <rec_20090930_120512>
SN = < zero
FW1 = <50-50>
FW2 = <800-40 / ..... >
Phot = <aprox 30> phot/subap
Staged: <OFF>
Nota = <lamp 12% not saved the irtc images. problem with the exp time of the IRTC (0.7 sec and 100 frames . not works). the secondary RIP.

loading another shape from 200900928, and refocus with the hexapod. Z:-221.88

CLOOP <20091002_123751
20091002_123850>


Bin = <3>
LoopHz = <200>
tt:<6L/D>
Pup = <>
Dist =< _ovfreq625.0_np4000.fits/ oversampling (all frames)
Gain = <0.7>
Rec = <rec_20090930_120512>
SN = < zero
FW1 = <50-50>
FW2 = <800-40 / ..... >
Phot = <aprox 25> phot/subap
Staged: <OFF>
Nota = <lamp 12%

CLOOP <20091002_123955
20091002_124047> diagonitc at 100Hz secondary RIP

IRTC DARK: 20091002_124317
Bin = <3>
LoopHz = <200>
tt:<6L/D>
Pup = <>
Dist =< _ovfreq625.0_np4000.fits/ oversampling (all frames)
Gain = <0.7>
Rec = <rec_20090930_120512>
SN = < zero
FW1 = <600>
FW2 = <800-40 / ..... >
Phot = <aprox 40> phot/subap
Staged: <OFF>
Nota = <lamp 12%

CLOOP <20091002_130315

20091002_130402>

IRTC DARK: 20091002_124317
Bin = <3>
LoopHz = <200>
tt:<6L/D>
Pup = <>
Dist =< _ovfreq800.0_np4000.fits/ oversampling (all frames) (ovs=600)mismatch!!

Gain = <0.7>
Rec = <rec_20090930_120512>
SN = < zero
FW1 = <600>
FW2 = <800-40 / ..... >
Phot = <aprox 43> phot/subap
Staged: <OFF>
Nota = <lamp 12%

CLOOP <20091002_130649

20091002_130726>

IRTC DARK: 20091002_124317
Bin = <3>
LoopHz = <200>
tt:<6L/D>
Pup = <>
Dist =< _ovfreq800.0_np4000.fits/ oversampling (all frames)

Gain = <0.7>
Rec = <rec_20090930_120512>
SN = < zero
FW1 = <600>
FW2 = <800-40 / ..... >
Phot = <aprox 43> phot/subap
Staged: <OFF>
Nota = <lamp 12% c

final dark acquired: _130912 done with the lamp off.

REC_20090930_120718 80 MODES

CLOOP <20091002_141529


Bin = <3>
LoopHz = <200>
tt:<6L/D>
Pup = <>
Dist =< _ovfreq800.0_np4000.fits/ oversampling (all frames)
Gain = <0.7>
Rec = <rec_20090930_120718>
SN = < zero
FW1 = <600>
FW2 = <800-40 / ..... >
Phot = <aprox 4000> phot/subap
Staged: <On>
Nota = < HIGH FLUX.

CLOOP <20091002_142301
20091002_142407

Bin = <3>
LoopHz = <200>
tt:<6L/D>
Pup = <>
Dist =< _ovfreq800.0_np4000.fits/ oversampling (all frames)
Gain = <0.6>
Rec = <rec_20090930_120718>
SN = < zero
FW1 = <600>
FW2 = <800-40 / ..... >
Phot = <aprox 40> phot/subap
Staged: <OFF>
Nota = < . nMODES:80 STAGE ON

Rec:20090930_120625 100 MODES

CLOOP <20091002_142554

Bin = <3>
LoopHz = <200>
tt:<6L/D>
Pup = <>
Dist =< _ovfreq800.0_np4000.fits/ oversampling (all frames)
Gain = <0.6>
Rec = <rec_20090930_120625>
SN = < zero
FW1 = <600>
FW2 = <800-40 / ..... >
Phot = <aprox 40> phot/subap
Staged: <ON>
Nota = < . nMODES:80

CLOOP <20091002_142701
20091002_142813


Bin = <3>
LoopHz = <200>
tt:<6L/D>
Pup = <>
Dist =< _ovfreq800.0_np4000.fits/ oversampling (all frames)
Gain = <0.6>
Rec = <rec_20090930_120625>
SN = < zero
FW1 = <600>
FW2 = <800-40 / ..... >
Phot = <aprox 40> phot/subap
Staged: <OFF>
Nota = < . nMODES:80 STAGE OFF
REC_20090930_120718 80 MODES

CLOOP <20091002_142944
20091002_ NOT DONE
20091002_143201
20091002_143311

Bin = <3>
LoopHz = <200>
tt:<6L/D>
Pup = <>
Dist =< _ovfreq800.0_np4000.fits/ oversampling (all frames)
Gain = <0.6>
Rec = <rec_20090930_120718>
SN = < zero
FW1 = <600>
FW2 = <800-40 / ..... >
Phot = <aprox 40> phot/subap
Staged: <OFF>
Nota = < .DURING THE SECOND ACQUISITION SKIP FRAME
REC <Rec:20090930_120512> 60 MODES.
CLOOP <20091002_143500

20091002_143617


Bin = <3>
LoopHz = <200>
tt:<6L/D>
Pup = <>
Dist =< _ovfreq800.0_np4000.fits/ oversampling (all frames)
Gain = <0.6>
Rec = <rec_20090930_120512>
SN = < zero
FW1 = <600>
FW2 = <800-40 / ..... >
Phot = <aprox 40> phot/subap
Staged: <OFF>
Nota = < .

IRTC DARK:_144203

.............BIN 4

Starting to acquire the rec for the binning 4


INTMATACQ <IntMat_20091002_14594>
Pup = <bin4/20090928_222848> Digital.
Dist = <cmddist_20090930_100717>
Iteration = <4>
Loop speed = <200 Hz>
bin <4>
Modul =<6l/D Z>
Rec.Close loop <rec_>
Gain vector close loop = <>

Analyse IntMat.

REC <Rec_20091002_150243>
Modal Basis:<KL>
intmatacq = <IntMat_20091002_145944>
n modes = <35>
cutted = <1>
Note: <good with 100 modes................>

Acquire a new Int Mat with the close loop.

INTMATACQ <IntMat_20091002_150613>
Pup = <20090928_222848>>
Dist = <cmddist_20090930_100717>
Iteration = <4>
Loop speed = <200 Hz>
bin <4>
Modul =<6l/D Z>
Rec.Close loop <Rec_20091002_150243>
Gain vector close loop = <gain0.05>

Analyse IntMat at close loop.

REC <Rec_20091002_150920>
Modal Basis:<KL>
intmatacq = <IntMat_20091002_150613>
n modes = <35>
cutted = <1>
skip<2>
avg frame <2>

Note: <....>

Rec_20091002_150920 bin 4, 6L/D, modes 35

It has been that there is one pixel in the pupil which is not counting. this effect could affect to the calculation of the slopes.
Testing this rec at close loop the secondary RIP.

problem with the network, to continue the observations we moved to the tower.

Stop observations and the problem is starting to be traced. It has been working to understand why in bin 4 we see one pixel off.

-- JuanCarlosGuerra - 2009-10-02