Start up w ok.
Secondary , problem with the cooling system. too hot to power on the secondary.
A bypass system is put in place, and it is working with the backup system (water).

TEST OF PSF POSITIONS IN THE IRTC

PSF in the IRTC after start up of the system.Four step check.
WFS setup HEXAPOD
power:
breaks:
homming
position:
SECONDARY
FLAT
IRTC
FOV
nota
irtc_v6 ON
OFF
20090925/flat_400modes Wide The spot is not in the IRTC FOV. The hexapod was parked before to power off
"" ON
ON
ON
"" "" The spot is not in the IRTC FOV
" " ON
ON
OK
last good positions[-504,1980.7,-221.67,183.15,-35.65,0]
" " " " The spots are in the IRTC FOV at the position (167,122)
" " IN POSITION " " NARROW The spot is in the field, but with a big defocus.

irtc save directory: R:/IRTC_Data/20090928111522/
TEST CLOSE LOOP. OK.


REc: Rec_20090925_151900.
Modes: 400
200Hz.
3L/D.
gain:0.5
Dist:off.
Nota: known bug in the control software. Close the loop rip the secondary after open and close the loop

looking the IRTC PSF seems that the position of the stage Z is not right.

BOARD SET UP SAVED: irtc_v6

AUTOFOCUS IRTC PROCEDURE.

Best focus found at: 45.6
TEST NEW DISTURBANCES

dist_atm_s0.8_L040.0_v15.0_ovfreq1000.00_np4000.fits
dist_atm_s0.8_L040.0_v15.0_ovfreq800.00_np4000.fits

Error loading: error message: " too large amplitude "

AFTER LUNCH TIME THE PSF IN THE IRTC WIDE FOV IS FOUND AT:TOO MUCH DEFOCUS!

La psf sul 39 appare devisamente sfuocata (W saturato a 3 l/D @200HZ)

Questo perche' prima abbiamo cambiato di 3mm il fuoco usando le slitte e quindi l'ADSEC e non l'esapodo.

Adesso teniamo le slitte ferme e fuocheggiamo guardando il 39 e muovendo l'esapodo in Z
Posizione di partenza = -504.5, 1980.7; -166.1; 183.1; -85.6; 0

Focus e centering con esapodo.
Posizione finale = -504.5;1980.7;-76; 184.2; -36; 0

Loop chiuso di spianamento.

Flat del mirror registrato: flat_cloop_400modes_2

Proviamo a rifare il punto ad alti fotoni di Fernando

CLOOP <20090928_151058> no dist 1000Hz
IRTC cube = <irtc_00003_cube.fit>
IRTC dark = <irtc_00004_cube.fit>
Bin = <1>
LoopHz = <1000>
Pup = <?????>
Dist =<off>
Gain = <0.3>
Rec = <20090925_151900>
SN = <zero
FW1 = <700-1000>
FW2 = <800-10>
Phot = <1500> phot/subap
Nota = <SR H band 99.8>

cambiato il disturbo e messo ilnuovo disturbo di Fernando

CLOOP <20090928_152035> dist nuovo 1000Hz
IRTC cube = <irtc_00005_cube.fit>
IRTC dark = <irtc_00004_cube.fit>
Bin = <1>
LoopHz = <1000>
Pup = <?????>
Dist =<dist_atm_s0.8_L040.0_v15.0_OVfreq1000.00_np4000.fits>
Gain = <0.3>
Rec = <20090925_151900>
SN = <zero
FW1 = <700-1000>
FW2 = <800-10>
Phot = <1500> phot/subap
Nota = <................>

CLOOP <20090928_152817> dist nuovo 1000Hz
IRTC cube = <irtc_00006_cube.fit>
IRTC dark = <irtc_00004_cube.fit>
Bin = <1>
LoopHz = <1000>
Pup = <?????>
Dist =<dist_atm_s0.8_L040.0_v15.0_OVfreq1000.00_np4000.fits>
Gain = <0.3>
Rec = <20090925_151900>
SN = <zero
FW1 = <700-1000>
FW2 = <800-10>
Phot = <circa 200> phot/subap
Nota = <................>

CLOOP <20090928_153109> dist nuovo 1000Hz
IRTC cube = <irtc_00007_cube.fit>
IRTC dark = <irtc_00004_cube.fit>
Bin = <1>
LoopHz = <1000>
Pup = <?????>
Dist =<dist_atm_s0.8_L040.0_v15.0_OVfreq1000.00_np4000.fits>
Gain = <0.3>
Rec = <20090925_151900>
SN = <zero
FW1 = <700-1000>
FW2 = <800-10>
Phot = <circa 200> phot/subap
Nota = <................>

LOOP <20090928_153640> dist nuovo 1000Hz
IRTC cube = <irtc_00008_cube.fit>
IRTC dark = <irtc_00010_cube.fit>
Bin = <1>
LoopHz = <1000>
Pup = <?????>
Dist =<dist_atm_s0.8_L040.0_v15.0_OVfreq1000.00_np4000.fits>
Gain = <0.0>
Rec = <20090925_151900>
SN = <zero
FW1 = <700-1000>
FW2 = <800-10>
Phot = <circa 800> phot/subap
Nota = <closed loop with gain 0 seeing limited PSF>

CL #1

LOOP <20090928_154528> dist nuovo 1000Hz
IRTC cube = <irtc_00011_cube.fit>
IRTC dark = <irtc_00013_cube.fit>
Bin = <1>
LoopHz = <1000>
Pup = <?????>
Dist =<dist_atm_s0.8_L040.0_v15.0_OVfreq1000.00_np4000.fits>
Gain = <0.3>
Rec = <20090925_151900>
SN = <zero
FW1 = <700-1000>
FW2 = <800-10>
Phot = <circa 200> phot/subap
Nota = <CL #1>

LOOP <20090928_154709> dist nuovo 1000Hz
IRTC cube = <irtc_00012_cube.fit>
IRTC dark = <irtc_00013_cube.fit>
Bin = <1>
LoopHz = <1000>
Pup = <?????>
Dist =<dist_atm_s0.8_L040.0_v15.0_OVfreq1000.00_np4000.fits>
Gain = <0.3>
Rec = <20090925_151900>
SN = <zero
FW1 = <700-1000>
FW2 = <800-10>
Phot = <circa 200> phot/subap
Nota = <CL #2>

LOOP <20090928_155503> dist nuovo 1000Hz
IRTC cube = <irtc_00014_cube.fit>
IRTC dark = <irtc_00016_cube.fit>
Bin = <1>
LoopHz = <1000>
Pup = <?????>
Dist =<dist_atm_s0.8_L040.0_v15.0_OVfreq1000.00_np4000.fits>
Gain = <0.3>
Rec = <20090925_151900>
SN = <zero
FW1 = <700-1000>
FW2 = <800-10>
Phot = <circa 80> phot/subap
Nota = <CL #1>

LOOP <20090928_155838> dist nuovo 1000Hz
IRTC cube = <irtc_00014_cube.fit>
IRTC dark = <irtc_00016_cube.fit>
Bin = <1>
LoopHz = <1000>
Pup = <?????>
Dist =<dist_atm_s0.8_L040.0_v15.0_OVfreq1000.00_np4000.fits>
Gain = <0.3>
Rec = <20090925_151900>
SN = <zero
FW1 = <700-1000>
FW2 = <800-10>
Phot = <circa 80> phot/subap
Nota = <CL #2>

LOOP <20090928_160424> dist nuovo 1000Hz
IRTC cube = <irtc_00017_cube.fit>
IRTC dark = <irtc_00016_cube.fit>
Bin = <1>
LoopHz = <1000>
Pup = <?????>
Dist =<dist_atm_s0.8_L040.0_v15.0_OVfreq1000.00_np4000.fits>
Gain = <0.0>
Rec = <20090925_151900>
SN = <zero
FW1 = <700-1000>
FW2 = <800-10>
Phot = <circa 1300> phot/subap
Nota = <seeing limited>

LOOP <20090928_160631> dist nuovo 1000Hz
IRTC cube = <irtc_00018_cube.fit>
IRTC dark = <irtc_00016_cube.fit>
Bin = <1>
LoopHz = <1000>
Pup = <?????>
Dist =<dist_atm_s0.8_L040.0_v15.0_OVfreq1000.00_np4000.fits>
Gain = <0.0>
Rec = <20090925_151900>
SN = <zero
FW1 = <700-1000>
FW2 = <800-10>
Phot = <circa 1300> phot/subap
Nota = <seeing limited>

Controlliamo PSF open-loop e si ha visto un picco nel centro.

Ipotesi: c'e un paio di frames durante l'applicazione del disturbo che vanno a zero.

Working on in this effect of the spot during a close loop at gain 0.

it has been seen that it is necessary to load the shape before close loop

Or it can be: disable disturb.
open the loop.
load the shape
.

LOOP <20090928_170753> dist nuovo 1000Hz
20090918_170917
IRTC cube = <irtc_00019_cube.fit> <irtc_00020_cube.fit>

IRTC dark = <irtc_00021_cube.fit>
Bin = <1>
LoopHz = <1000>
Pup = <?????>
Dist =<dist_atm_s0.8_L040.0_v15.0_OVfreq1000.00_np4000.fits>
Gain = <0.0>
Rec = <20090925_151900>
SN = <zero
FW1 = <700-1000>
FW2 = <800-10>
Phot = <circa 1600> phot/subap
Nota = <seeing limited>

agiustamneto del fuoco usando l'esapodo

nuova pos esapodo

-504, 1980, -106, 184, -36, 0

LOOP <20090928_181545> dist nuovo 1000Hz
IRTC cube = <irtc_00022_cube.fit>

IRTC dark = <irtc_00023_cube.fit>
Bin = <1>
LoopHz = <1000>
Pup = <?????>
Dist =<dist_atm_s0.8_L040.0_v15.0_OVfreq1000.00_np4000.fits>
Gain = <0.6 sui primi 153 modi, da 153 in su gain =0>
Rec = <20090925_151900>
SN = <zero
FW1 = <700-1000>
FW2 = <800-10>
Phot = <circa 1000> phot/subap
Nota = <>

LOOP <20090928_182347> dist nuovo 1000Hz
IRTC cube = <irtc_00024_cube.fit>

IRTC dark = <irtc_00025_cube.fit>
Bin = <1>
LoopHz = <1000>
Pup = <?????>
Dist =<dist_atm_s0.8_L040.0_v15.0_OVfreq1000.00_np4000.fits>
Gain = <0.5 sui primi 153 modi, da 153 in su gain =0>
Rec = <20090925_151900>
SN = <zero
FW1 = <700-1000>
FW2 = <800-10>
Phot = <circa 40> phot/subap
Nota = <>

LOOP <20090928_182347> dist nuovo 1000Hz
IRTC cube = <irtc_00024_cube.fit>

IRTC dark = <irtc_00025_cube.fit>
Bin = <1>
LoopHz = <1000>
Pup = <?????>
Dist =<dist_atm_s0.8_L040.0_v15.0_OVfreq1000.00_np4000.fits>
Gain = <0.5 sui primi 250 modi, da 250 in su gain =0>
Rec = <20090925_151900>
SN = <zero
FW1 = <700-1000>
FW2 = <800-10>
Phot = <circa 40> phot/subap
Nota = <>

rec:
bin:1
nModes:250

REC <Rec_20090928_164500>
intmatacq = <>
n modes = <250>
cutted = <#>
Note: <................>

Test of the Rec... Cebra at gain:0.1. NOT GOOD.

PUPILLE BIN2 SINTETICHE

Scritta procedura di binning digitale a partire dalle pupille bin1.
Criterio per selezionare una subap: riempimento >=0.5 rispetto al bin1 (2 subap a bin2, 5 a bin3, 8 a bin4).

Pup = 20090928-221919
bin=2

ottenute a partire da quelle a bin1: 20090925-113454 (HOT pupils)
177 subap.

Pup = 20090928-20090928-222825
bin=3

ottenute a partire da quelle a bin1: 20090925-113454 (HOT pupils)
72 subap.

Pup = 20090928-20090928-222848
bin=4

ottenute a partire da quelle a bin1: 20090925-113454 (HOT pupils)
47 subap.

-- JuanCarlosGuerra - 2009-09-28
Topic revision: r3 - 28 Sep 2009, AlfioPuglisi
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback