Start up. Ok.
Secondary up Ok.

Load board setup: torre 2

Acquired empty slopes (close loop at gain 0) to perform analysis of the slopes noise. those slopes will be used to to improve the IntMat acquisition.
PROBLEMS.

acquiring different intmat using the Acquire intmat gui and looking the modes, it's seems that the frame counter is not working properly,
time lost: 1h.
the problem has been identified. the Acquire software didn't set up the right ccd39 freq. The intmat acquire gui has been changed and a new bottom is inserted. This new button is labeled as loop speed (Hz)
OPTICAL LOOP DIAGONSTICS. 20090916_100728

ccd39: 200Hz.
TT: 6 (l/d)
bin:1
rec:
Gain:0
OPTICAL LOOP DIAGONSTIC.. 20090916_100812

ccd39: 200Hz.
TT: 6 (l/d)
bin:1
Gain:0

ACQUIRE AMPLITUD CALIBRATION SET.

load file: intmat_kl_10step.txt

INTMAT ACQ. SET: <20090917_105333, _105917, _110514, _110912, _111136,_111417, _111722, _112009, _112241 #>

N of files:10
Modal base: KL
noMODES:400
Pup = 20090916_144036
Dist : 20090916_142003, _14205920090916_14211220090916_14212620090916_142144, _142202,_142216,_142230,_14224620090916_142300
Modul = 2 l/D at 400 HZ
FW1: 600-1000

INTMAT ANALYSE

Saturation file: Rec_20090917_114240, _114403, _114637, _114842 _114935 _115137_115317 _115457 _115646

optimized_2lampda:ampiezze ottimizzate

cmd disturb 6 modi x 50 ciclo: 122328 - venuto male, c'è un solo ciclo invece dei 50 impostati
intmatAcq 6 modi: 122554

cmd disturb 6 modi x 1 ciclo: 123047 - venuto male, c'è un solo ciclo invece dei 50 impostati
intmatAcq 6 modi: 123148

cmd disturb 400 modi x 1 ciclo amp optimized: 123542 - venuto male, c'è un solo ciclo invece dei 50 impostati
intmatAcq 400 modi: 123621

142028 IntmatACQ 4000 modi x 4 iterazioni KL amp_optimized

REC 5 MODI 2 lambda 143257.

analysis of the actuator position at close loop with a Rec with 5 modes at gain:0.01.
Pattern file:142_480

Misura magnification pupilla

Si applica un pattern di 2 act su, si applicano le sn e poi si chiude il loop di 5 modi e si applica il pattern identico ma giu' e si acquisiscono le slopes.


rec:_143257
Nmodes:5
Loop freq:400Hz.
Tt:2 l/D


Si calcola l'interdistanza fra i segnali in pix e si paragona a quellla teorica conoscendo l'interdistanza fisica fra gli acts (nel nome del file) e la sapendo il diametro del ADSEC e volendo 30.0pix di diametro

slopes saved: 20090917_144441
nslopes:1000
act pattern : pair_142.480_dis813.446.fits
Dist teorica: 26.79
Dist misur:26.42
Teor/mis = 1.014

slopes saved: 20090917_150157
act pattern : act_pair_159_464_dis812.223.fits
Dist teorica: 26.75
Dist misur: 27.29
Teor/mis = 0.980

slopes saved: 20090917_151218
act pattern : act_pair_30_353_dis812.223.fits
Dist teorica: 26.75pix
Dist misur: 27.02 pix
Teor/mis = 0.990

slopes saved: 20090917_152251
act pattern : act_pair_35_450_dis806.114.fits
Dist teorica: 26.55pix
Dist misur: 26.31pix
Teor/mis = 1.010

Media degli ingrandimenti 0.9983 con rms 0.02, quindi siamo ok con errore del 2%, mna sono 0.6pix sul diametro.

Ora proviamo ad aumentare le stime usando il ring 12

NEW PUPIL WITH A CENTER MOVED 0.5 PIXEL. They don't look right.
REVISION OF THE PUPIL MASK PROCEDURE, it has seen that the centers are not well calculated. Modified the software

PUPIL GOOD: 20090917_162439 (screenshot)

Centri = <56.5,20.5>
Dist = 36 pix
TTMod = <200Hz 22 l/D>

BINNING TEST OF PUPILS

Running the CCD39 binning program,it has seen that the lat of 36 is just right to have a good binning.

(screenshot)UP pupil right.
DOWN pupils with lato 37

ROTATION PUPIL. it has seen that the center has moved by 3 pixels with a rotation of the rerot. This has to be optimized.
PERFORMING CENTERING WITH THE REROTATOR.

Moving the stage in x or y and rotating the rerotator the center has to be found in a range of a displacement of about one pixel.
looking the test we couldn't determine a better performances, always we have about 3 pixels.

Runa genera un pattern di attuatori su-giu' su un diametro dell specchio.

triple_radial.fits

-- JuanCarlosGuerra - 2009-09-17
  • pupils ok:
    Pupille_tonde.png

  • binning test ccd39:
    Binning_test.png
Topic revision: r4 - 18 Sep 2009, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.