Kalman Filter

Rec_20090609_142233
F1:50%-50%.
F2:900-10.
Bin:1
CCD 39 Fre:400 Hz.
CCD 39 Read out:890
lambda/D =2.5
600 ph/sub
Test int con disturbo

OL dist_atmo_08_1000Hz_15ms_s35_80pix (sync) -> OLD 4000 frame PSF 50 frame (average) 113613

CL gain = 0.5 -> OLD 4000 frame PSF 50 frame (average) -> 113819 - 113911 - 114050
Vibrazione

OL disturb_f21.0000Hz_amp10.0000mas_tt0_b0_4p_dist_atmo_08_1000Hz_15ms_s35_80pix_fc400.000Hz -> OLD 4000 frame PSF 50 frame (average) 114320 - 114407

CL gain = 0.5 -> OLD 4000 frame PSF 50 frame (average) 114528 - 114615 - 114702

OL disturb_f21.0000Hz_amp20.0000mas_tt0_b0_4p_dist_atmo_08_1000Hz_15ms_s35_80pix_fc400.000Hz -> OLD 4000 frame PSF 50 frame (average) 114947 - 115034

CL gain = 0.5 -> OLD 4000 frame PSF 50 frame (average) 115152 - 115241 -115331

OL disturb_f21.0000Hz_amp50.0000mas_tt0_b0_4p_dist_atmo_08_1000Hz_15ms_s35_80pix_fc400.000Hz -> OLD 4000 frame PSF 50 frame (average) 115555 - 115648

CL gain = 0.5 -> OLD 4000 frame PSF 50 frame (average) 115810 - 115857 - 115950

OL disturb_f21.0000Hz_amp100.0000mas_tt0_b0_4p_dist_atmo_08_1000Hz_15ms_s35_80pix_fc400.000Hz -> OLD 4000 frame PSF 50 frame (average) 120205 - 120258

CL gain = 0.5 -> OLD 4000 frame PSF 50 frame (average) 120439 - 120536 (skip modo 151) - 120814 - 120918

OL disturb_f21.0000Hz_amp150.0000mas_tt0_b0_4p_dist_atmo_08_1000Hz_15ms_s35_80pix_fc400.000Hz -> OLD 4000 frame PSF 50 frame (average) 121105 - 121205

CL gain = 0.5 -> OLD 4000 frame PSF 50 frame (average) 121341 - 121434 - 121544 - 121646
Doppia vibrazione

OL disturb_f7.0000Hz21.0000Hz_amp100.0000mas100.0000mas_tt0_b0_4p_dist_atmo_08_1000Hz_15ms_s35_80pix_fc400.000Hz -> OLD 4000 frame PSF 50 frame (average) 122128 - 122218.

load shape

CL gain = 0.5 -> OLD 4000 frame PSF 50 frame (average) 122549 - 122643 - 122747

OL disturb_f7.0000Hz21.0000Hz_amp100.0000mas100.0000mas_tt0_b0_4p_dist_atmo_08_1000Hz_15ms_s35_80pix_fc400.000Hz -> OLD 4000 frame PSF 50 frame (average) 123244 - 123357

CL 400Hz_7_21Hz_d0001_0001_s2e7_8e7_s12_c_AR_142233_1000ph gain = 0.5 -> OLD 4000 frame PSF 50 frame (average) 123551 - 123654 - 123801
Vibrazione ampia

OL disturb_f0.0000Hz_amp0.0000mas_tt0_b17_5_4p_dist_atmo_08_1000Hz_15ms_s35_80pix_fc400.000Hz (pow 2e-7) -> OLD 4000 frame PSF 50 frame (average) 124019 - 124119

CL 400Hz_17_5Hz_d003_s5e6_s8_c_AR_142233_1000ph gain = 0.5 -> OLD 4000 frame PSF 50 frame (average) 124328 - 124428 - 124630

OL disturb_f0.0000Hz_amp0.0000mas_tt0_b17_5_4p_dist_atmo_08_1000Hz_15ms_s35_80pix_fc400.000Hz (pow 2e-7) -> OLD 4000 frame PSF 50 frame (average) 124814 - 124956

CL gain = 0.5 -> OLD 4000 frame PSF 50 frame (average) 125141 - 125248 - 125419
Prova a 800Hz

200 ph/sub
800Hz

CL 800Hz_21Hz_d0001_s2e7_s8_c_AR_142233_1000ph gain = 0.5 -> OLD 4000 frame PSF 50 frame (average) 125953 gain = 0.5 -> OLD 4000 frame PSF 50 frame (average) 130104

OL -> OLD 4000 frame PSF 50 frame (average) 130211

CL 800Hz_21Hz_d001_s2e7_s8_c_AR_142233_1000ph gain = 0.5 -> OLD 4000 frame PSF 50 frame (average) 130332

-- GuidoAgapito - 2009-08-04
Topic revision: r1 - 04 Aug 2009, GuidoAgapito
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.