OPTICAL SET UP IRTC.

LOAD SHAPE the secondary stop during the load shape, the secondary shows a "dent" in the outer ring. After a load shape it looks like that it improve, but there is still a residual.
After a second load shape,the secondary went to failed. EXECUTING the command load shape. It was necessary to restart the process IDL.
Saved frames: /towerdata/adsec_data/20090727/dente.fits (10 frames).
Close the loop to improve the shape. The secondary went to Failure error:"adsec unprotected".

Changes in the analysis,acquire and analyse guis.Alfio improved.
GENERATING PP INTMAT @ DIFFERENT AMPLITUDE FILES.

changing the amplitude file for 650 modes and TT 8 L/D to work at different amplitudes with the amplitude of the sinusoidal files.

-Acquire Distrubance.
NModes:650.
Frame:5.
skip:2.
-Acquire Intmat
iteration:4.

file saved: /towerdata/adsec_calib/M2C/
PP_amplitude
Cmd disturbance
Int mat
Rec
NOTE
pp_650_mod8_s0.012.fits
CmdDist20090727 _113646
pp_650_mod8_s0.025.fits
CmdDist20090727_113622
pp_650_mod8_s0.05.fits
CmdDist20090727_113553
pp_650_mod8_s0.1.fitsCmdDist20090727_113529
pp_650_mod8_s0.2.fitsCmdDist20090727_113504
pp_650_mod8_s0.4.fits
CmdDist20090727_113442 IntMat _20090727_121751Rec_20090727_121751
only the first 400 modes ok
pp_650_mod8_s0.8.fits
CmdDist20090727_113421 force too large
-
pp_650_mod8_s1.6.fitsCmdDist20090727 _113341 force too large
-

pp_650_mod8_s0.012.fits...CmdDist20090727_113646.....slopesAcq 20090727_135352 Intmat/Rec_20090727_140502
pp_650_mod8_s0.025.fits...CmdDist20090727_113622.....slopesAcq 20090727_134600 Intmat/Rec_20090727_140101
pp_650_mod8_s0.05.fits.....CmdDist20090727_113553.... slopesAcq 20090727_131359 Intmat/Rec_20090727_135724
pp_650_mod8_s0.1.fits.......CmdDist20090727_113529.... slopesAcq 20090727_130422 IntMat/Rec_20090727_135451
pp_650_mod8_s0.2.fits.......CmdDist20090727_113504.... slopesAcq 20090727_125506 IntMat/Rec_20090727_135127.
pp_650_mod8_s0.4.fits.......CmdDist20090727_113442.... slopesAcq _20090727_121751 IntMat/Rec_20090727_124049 -Note:only the first 400 modes the other are saturated

pp_650_mod8_s0.8.fits.......CmdDist20090727_113421....THE SECONDARY CAN NOT MAKE IT ...........TOO LARGE FORCE......
pp_650_mod8_s1.6.fits...... CmdDist20090727 _113341...THE SECONDARY CAN NOT MAKE IT ...........TOO LARGE FORCE......

SINUSOIDAL ACQUISITION SET.

SINUSOIDAL ACQUIRE PROCEDURE:


- TAKING A CLOSE LOOP AT GAIN 0 TO CHARACTERISE THE NOISE OF THE SLOPES.
- SET OF PUSH PULL AND SINUSOIDAL INTMAT AT DIFFERENT AMPLITUDE CONFIGURATIONS.

ACQUIRE SET OF SINUSOIDAL FILE.
- PP amplitude of 0.2

SYSTEM SET UP.
- CCD39:196 Hz.
-TT. 4.
-Rec:20090603_151453 (650 MODES)
-GAIN:0

OPTICAL LOOP DIAGNOSTICS: 20090727_112424.
- CCD39:196 Hz.
-TT. 4.
-Rec:20090603_151453 (650 MODES), -amplitude file: pp_650.fits.,.TT:6
-Gain:0.
- Phot/subap: 1600.

- s0.2_mod400ccd_30hz_20m.txt. DONE.

- s0.6_mod400ccd_30hz_20m.txt. DONE... ONLY THE FIRST 5.

- s0.4_mod400ccd_30hz_20m.txt. DONE.
nota: the secondary failed. Recover fail.it wasn't skipping frame. Seems that it was the -close loop secondary rip-.
After a load shape the secondary hung. last command load shape EXECUTING time: 12:27. Restarting IDL controller.rip the secondary by command line in IDL.
shave an image of the pupils piato.fits.

- s0.1_mod400ccd_30hz_20m.txt. DONE.

- s1_mod400ccd_30hz_20m.txt. DONE.

PSF vari filtri a cloop

Rec:REc_20090609_142233 (verificato TTAMP 0.9V e probabilmente a 200Hz quindi 2.0 lambda/D)
NModes:351
Gain: 0.5
CCD39:196 Hz.
CCD39 Read out.
CCD47: 3.5Hz.
CCD47 Read out:
FW1. changing in the measurements.
FW2. changing in the measurements.
TT:2.0.
pHOTON/SUBAPER:1600.
850-10900-10
50%-50%



90%-10%

600-1000

700-1000
psf15_ccd47 / psf16_ccd47
------ / psf16_seq_ccd47
CL: 20090724_165505

Rinunciamo troppo vento e psf molto ballerina

- JuanCarlosGuerra - 2009-07-27
Topic revision: r5 - 04 Aug 2009, GuidoAgapito
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.