MOUNT THE DICHROIC FOR THE IRTC.

CHECK WITH THE CCD47 IF WE CAN SEE THE SECONDARY,SPIRAL SEARCH.
FOUND POINT: X:-78, Y:40.

PSF1.fits.
adsec_data/20090717/
FW1: Mirror
FW2:empty
Source:thorlab lamp (Max).
focus (z stage):43. Torre 10 setup.
CCD47:3.5Hz.

PUPIL POSITION FOR THE CCD39 IS LESS THAN 1 PIXEL RESPECTS TO THE DUMMY MIRROR.

-TRY CLOSE LOOP WITH THE REC_ WITH GAIN 0.001 TO IMPROVE THE MIRROR FLATENNING.
-AFTER THECLOSE THE LOOP THE PSF IMPROVES. SAVED CCD39 IMAGE (CCD39_2.FITS) IT'S LOOKS LIKE THAT THERE IS SOME REFLECTION --GHOST-- AND IMAGE IN THE CCD47 (PSF2.FITS).
- AFTER MOVING THE CUBE BY 0.1 THE GHOST DISPEAR AND THE PUPILS LOOKS RIGHT.
- The PSF has been center in the CCD39 moving the stage in X and Y. ABOUT 4.5 mm vertical displacement. And 0.2 mm horizontal displacement. The Z about 20mm backward from the torre10 bin2 setup.


BOARD SETUP SAVED: IRTC


PSF3.FITS, CCD39_3.FITS
OPTICAL LOOP SAVED:20090717_153904
Board setup: IRTC.
Rec: REC_20090609_142233.
GAIN:0.4.
fw1: 50-50
fw2:900-1000

PSF4.FITS, CCD39_4.FITS
OPTICAL LOOP SAVED:20090717_154326
Board setup: IRTC.
Rec: REC_20090609_142233.
GAIN:0.0
fw1: 50-50
fw2:900-1000

-- JuanCarlosGuerra - 2009-07-17
Topic revision: r2 - 22 Jul 2009, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.