Disturbance with oversampling.

Test OK. Oversampling is set to the biggest multiple of the loop frequency smaller than 900 Hz.

CLOOP RTF test (total delay & atmosphere)

CLOOP 185609
Bin = 1
Hz = 196
Mod = +-2.0 l/D
39Readspeed = 890 kpix/s
Pup = solite bin 1
Dist = dist_atmo_08_1000Hz_15ms_s35_80pix.fits (synch WFS)
Gain = 0.5
Rec = 142233 (351 modes)
SN = zero
FW1 = 600 dicr
FW2 = 850-10
Phot = 2500/subap

CLOOP 185647
Bin = 1
Hz = 196
Mod = +-2.0 l/D
39Readspeed = 890 kpix/s
Pup = solite bin 1
Dist = dist_atmo_08_1000Hz_15ms_s35_80pix.fits (oversamp)
Gain = 0.5
Rec = 142233 (351 modes)
SN = zero
FW1 = 600 dicr
FW2 = 850-10
Phot = 2500/subap

CLOOP 185946
Bin = 1
Hz = 196
Mod = +-2.0 l/D
39Readspeed = 400 kpix/s
Pup = solite bin 1
Dist = dist_atmo_08_1000Hz_15ms_s35_80pix.fits (sync WFS)
Gain = 0.5
Rec = 142233 (351 modes)
SN = zero
FW1 = 600 dicr
FW2 = 850-10
Phot = 2500/subap

CLOOP 190042
Bin = 1
Hz = 196
Mod = +-2.0 l/D
39Readspeed = 400 kpix/s
Pup = solite bin 1
Dist = dist_atmo_08_1000Hz_15ms_s35_80pix.fits (oversamp)
Gain = 0.5
Rec = 142233 (351 modes)
SN = zero
FW1 = 600 dicr
FW2 = 850-10
Phot = 2500/subap

OLOOP 190849
Bin = 1
Hz = 196
Mod = +-2.0 l/D
39Readspeed = 890 kpix/s
Pup = solite bin 1
Dist = dist_atmo_08_1000Hz_15ms_s35_80pix.fits (sync WFS)
Gain = 0.0
Rec = 142233 (351 modes)
SN = zero
FW1 = 600 dicr
FW2 = 850-10
Phot = 2500/subap

OLOOP 191002

Bin = 1
Hz = 196
Mod = +-2.0 l/D
39Readspeed = 890 kpix/s
Pup = solite bin 1
Dist = dist_atmo_08_1000Hz_15ms_s35_80pix.fits (oversamp)
Gain = 0.0
Rec = 142233 (351 modes)
SN = zero
FW1 = 600 dicr
FW2 = 850-10
Phot = 2500/subap

OLOOP 191201 (ERROR: NO wfs.fits and no adsec.sav saved.... how come?????)
Bin = 1
Hz = 196
Mod = +-2.0 l/D
39Readspeed = 400 kpix/s
Pup = solite bin 1
Dist = dist_atmo_08_1000Hz_15ms_s35_80pix.fits (sync WFS)
Gain = 0.0
Rec = 142233 (351 modes)
SN = zero
FW1 = 600 dicr
FW2 = 850-10
Phot = 2500/subap

OLOOP 191308
Bin = 1
Hz = 196
Mod = +-2.0 l/D
39Readspeed = 400 kpix/s
Pup = solite bin 1
Dist = dist_atmo_08_1000Hz_15ms_s35_80pix.fits (oversamp)
Gain = 0.0
Rec = 142233 (351 modes)
SN = zero
FW1 = 600 dicr
FW2 = 850-10
Phot = 2500/subap

CLOOP RTF test (different gains)

  • The readout speed was set to 400kpix/s and the sampling frequency to 196Hz.

CLOOP 191520
Bin = 1
Hz = 196
Mod = +-2.0 l/D
39Readspeed = 400 kpix/s
Pup = solite bin 1
Dist = dist_atmo_08_1000Hz_15ms_s35_80pix.fits (sync WFS)
Gain = 0.1
Rec = 142233 (351 modes)
SN = zero
FW1 = 600 dicr
FW2 = 850-10
Phot = 2400/subap

CLOOP 191615
Bin = 1
Hz = 196
Mod = +-2.0 l/D
39Readspeed = 400 kpix/s
Pup = solite bin 1
Dist = dist_atmo_08_1000Hz_15ms_s35_80pix.fits (sync WFS)
Gain = 0.2
Rec = 142233 (351 modes)
SN = zero
FW1 = 600 dicr
FW2 = 850-10
Phot = 2400/subap

CLOOP 191701
Bin = 1
Hz = 196
Mod = +-2.0 l/D
39Readspeed = 400 kpix/s
Pup = solite bin 1
Dist = dist_atmo_08_1000Hz_15ms_s35_80pix.fits (sync WFS)
Gain = 0.3
Rec = 142233 (351 modes)
SN = zero
FW1 = 600 dicr
FW2 = 850-10
Phot = 2400/subap

CLOOP 191742
Bin = 1
Hz = 196
Mod = +-2.0 l/D
39Readspeed = 400 kpix/s
Pup = solite bin 1
Dist = dist_atmo_08_1000Hz_15ms_s35_80pix.fits (sync WFS)
Gain = 0.4
Rec = 142233 (351 modes)
SN = zero
FW1 = 600 dicr
FW2 = 850-10
Phot = 2400/subap

CLOOP 191818 (ERROR: NO wfs.fits and no adsec.sav saved.... how come?????)
Bin = 1
Hz = 196
Mod = +-2.0 l/D
39Readspeed = 400 kpix/s
Pup = solite bin 1
Dist = dist_atmo_08_1000Hz_15ms_s35_80pix.fits (sync WFS)
Gain = 0.5
Rec = 142233 (351 modes)
SN = zero
FW1 = 600 dicr
FW2 = 850-10
Phot = 2400/subap

CLOOP 191845
Bin = 1
Hz = 196
Mod = +-2.0 l/D
39Readspeed = 400 kpix/s
Pup = solite bin 1
Dist = dist_atmo_08_1000Hz_15ms_s35_80pix.fits (sync WFS)
Gain = 0.6
Rec = 142233 (351 modes)
SN = zero
FW1 = 600 dicr
FW2 = 850-10
Phot = 2400/subap

CLOOP 191931
Bin = 1
Hz = 196
Mod = +-2.0 l/D
39Readspeed = 400 kpix/s
Pup = solite bin 1
Dist = dist_atmo_08_1000Hz_15ms_s35_80pix.fits (sync WFS)
Gain = 0.7
Rec = 142233 (351 modes)
SN = zero
FW1 = 600 dicr
FW2 = 850-10
Phot = 2400/subap

CLOOP 192007
Bin = 1
Hz = 196
Mod = +-2.0 l/D
39Readspeed = 400 kpix/s
Pup = solite bin 1
Dist = dist_atmo_08_1000Hz_15ms_s35_80pix.fits (sync WFS)
Gain = 0.8
Rec = 142233 (351 modes)
SN = zero
FW1 = 600 dicr
FW2 = 850-10
Phot = 2400/subap

  • The readout speed was set to 890kpix/s and the sampling frequency to 196Hz.

OLOOP 192657
Bin = 1
Hz = 196
Mod = +-2.0 l/D
39Readspeed = 890 kpix/s
Pup = solite bin 1
Dist = dist_atmo_08_1000Hz_15ms_s35_80pix.fits (sync WFS)
Gain = 0.0
Rec = 142233 (351 modes)
SN = zero
FW1 = 600 dicr
FW2 = 850-10
Phot = 2400/subap

CLOOP 192747
Bin = 1
Hz = 196
Mod = +-2.0 l/D
39Readspeed = 890 kpix/s
Pup = solite bin 1
Dist = dist_atmo_08_1000Hz_15ms_s35_80pix.fits (sync WFS)
Gain = 0.1
Rec = 142233 (351 modes)
SN = zero
FW1 = 600 dicr
FW2 = 850-10
Phot = 2400/subap

CLOOP 192826
Bin = 1
Hz = 196
Mod = +-2.0 l/D
39Readspeed = 890 kpix/s
Pup = solite bin 1
Dist = dist_atmo_08_1000Hz_15ms_s35_80pix.fits (sync WFS)
Gain = 0.2
Rec = 142233 (351 modes)
SN = zero
FW1 = 600 dicr
FW2 = 850-10
Phot = 2400/subap

CLOOP 192907
Bin = 1
Hz = 196
Mod = +-2.0 l/D
39Readspeed = 890 kpix/s
Pup = solite bin 1
Dist = dist_atmo_08_1000Hz_15ms_s35_80pix.fits (sync WFS)
Gain = 0.3
Rec = 142233 (351 modes)
SN = zero
FW1 = 600 dicr
FW2 = 850-10
Phot = 2400/subap

CLOOP 192953
Bin = 1
Hz = 196
Mod = +-2.0 l/D
39Readspeed = 890 kpix/s
Pup = solite bin 1
Dist = dist_atmo_08_1000Hz_15ms_s35_80pix.fits (sync WFS)
Gain = 0.4
Rec = 142233 (351 modes)
SN = zero
FW1 = 600 dicr
FW2 = 850-10
Phot = 2400/subap

CLOOP 193034 (doppione)
Bin = 1
Hz = 196
Mod = +-2.0 l/D
39Readspeed = 890 kpix/s
Pup = solite bin 1
Dist = dist_atmo_08_1000Hz_15ms_s35_80pix.fits (sync WFS)
Gain = 0.4
Rec = 142233 (351 modes)
SN = zero
FW1 = 600 dicr
FW2 = 850-10
Phot = 2400/subap

CLOOP 193115
Bin = 1
Hz = 196
Mod = +-2.0 l/D
39Readspeed = 890 kpix/s
Pup = solite bin 1
Dist = dist_atmo_08_1000Hz_15ms_s35_80pix.fits (sync WFS)
Gain = 0.5
Rec = 142233 (351 modes)
SN = zero
FW1 = 600 dicr
FW2 = 850-10
Phot = 2400/subap

CLOOP 193202
Bin = 1
Hz = 196
Mod = +-2.0 l/D
39Readspeed = 890 kpix/s
Pup = solite bin 1
Dist = dist_atmo_08_1000Hz_15ms_s35_80pix.fits (sync WFS)
Gain = 0.6
Rec = 142233 (351 modes)
SN = zero
FW1 = 600 dicr
FW2 = 850-10
Phot = 2400/subap

CLOOP 193241
Bin = 1
Hz = 196
Mod = +-2.0 l/D
39Readspeed = 890 kpix/s
Pup = solite bin 1
Dist = dist_atmo_08_1000Hz_15ms_s35_80pix.fits (sync WFS)
Gain = 0.7
Rec = 142233 (351 modes)
SN = zero
FW1 = 600 dicr
FW2 = 850-10
Phot = 2400/subap

CLOOP 193321
Bin = 1
Hz = 196
Mod = +-2.0 l/D
39Readspeed = 890 kpix/s
Pup = solite bin 1
Dist = dist_atmo_08_1000Hz_15ms_s35_80pix.fits (sync WFS)
Gain = 0.8
Rec = 142233 (351 modes)
SN = zero
FW1 = 600 dicr
FW2 = 850-10
Phot = 2400/subap