You are here: Foswiki>FLAO Web>TowerLab>TowerTest20090706 (06 Jul 2009, EnricoPinna)Edit Attach

PSF 47 con laser

Enrico e Juan Carlos

PSF00.fits
Source = laser He Ne
ADC = out
Fibra = 5.8um
FW1 = 50%
FW2 = 850-10
Average =100

PSF01.fits
Source = laser He Ne
ADC = out
Fibra = 5.8um
FW1 = 50%
FW2 = 850-10
Average =100

Istallata la thorlabs sul ramo TV

PSF_thorlab_00.fits
Source =laser He Ne
ADC = out
Fibra =5.8um
FW1 = window
FW2 = empty
sequence = 30

PSF_thorlab_01.fits
Source =laser He Ne
ADC = out
Fibra =5.8um
FW1 = window
FW2 = empty
sequence = 30

PASSIAMO ALLA LAMPADA e il filtro 850-10

PSF_thorlab_02.fits
Source =lampada
ADC = out
Fibra =5.8um
FW1 = mirror
FW2 = 850-10
sequence = 30

PSF_thorlab_03.fits
Source =lampada
ADC = out
Fibra =5.8um
FW1 = mirror
FW2 = 850-10
sequence = 30

Proviamo col dicroico

PSF_thorlab_04.fits
Source =lampada
ADC = out
Fibra =5.8um
FW1 = dicroic 600-1000
FW2 = 850-10
sequence = 30
Nota: fa schifo

Rimettiamo a fuoco perche' siamo dominati dal defocus

PSF_thorlab_05.fits
Source =lampada
ADC = out
Fibra =5.8um
FW1 = Mirror
FW2 = 850-10
sequence = 30
Nota: refocused

PSF_thorlab_06.fits
Source =lampada
ADC = out
Fibra =5.8um
FW1 = Mirror
FW2 = 850-10
sequence = 30

Proviamo col dicroico e senza 850-10 (con l'850-10 non si vede niente)

PSF_thorlab_07.fits
CCD = thorlabs
Source =lampada
ADC = out
Fibra =5.8um
FW1 = 700-1000
FW2 = empty
sequence = 30
Nota: riappare la croce da astigmatismo!!!!

PSF_thorlab_08.fits
CCD = thorlabs
Source =lampada
ADC = out
Fibra =5.8um
FW1 = 700-1000
FW2 = empty
sequence = 30

TORNIAMO AL 47!!!!! Senza rimuovere il pellicle beam splitter della thorlabs

Rifuocheggiamo

PSF_ccd47_09.fits
CCD = 47
Source =lampada
ADC = out
Fibra =5.8um
FW1 = 700-1000
FW2 = 850-10
sequence = 30

PSF_ccd47_10.fits
CCD = 47
Source =lampada
ADC = out
Fibra =5.8um
FW1 = 700-1000
FW2 = 850-10
sequence = 30

Mettiamo il filtro 900-10

PSF_ccd47_11.fits
CCD = 47
Source lampada
ADC = out
Fibra =5.8um
FW1 = 50%
FW2 = 900-10
average
30

PSF_ccd47_12.fits
CCD = 47
Source =lampada
ADC = out
Fibra =5.8um
FW1 = 50%
FW2 = 900-10
sequence = 30

PSF_ccd47_14.fits
CCD = 47
Source =lampada
ADC = out
Fibra =5.8um
FW1 = 700-1000
FW2 = 900-10
sequence = 30
Note: NON ARRIVA LUCE!

PSF_ccd47_15.fits
CCD = 47
Source =lampada
ADC = out
Fibra =5.8um
FW1 = 50%
FW2 = 900-10
average = 30

PSF_thorlabs_16.fits
CCD = thorlabs
Source =lampada
ADC = out
Fibra =5.8um
FW1 = 50%
FW2 = 900-10
sequence = 30

-- EnricoPinna - 2009-07-06
Topic revision: r2 - 06 Jul 2009, EnricoPinna
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback