You are here: Foswiki>FLAO Web>TowerLab>TowerTest20090619 (01 Jul 2009, FrancescaPieralli)Edit Attach

TEST OPERATION SYSTEM.

test cloop sinusoide

Juan Carlos,Guido,Francesca, Alfio.

cloop Data_20090619_110153

rec:rec_sin_351_b.fitgain=0.4

n_modes:351

tt:5.6 (ccd:400Hz)

counts:2000/px

set_up:torre10

cloop Data_20090619_105715

rec:142233.fits
gain=0.9

n_modes:351

tt:5.6 (ccd:400Hz)

counts:2000/px

set_up:torre10

PSF 20090619/psf.fits , openloop

average=300

PSF 20090619/psf2.fits , closeloop gain 0.4

average=300

*****onlyone_mode

Prendiamo i dati con nuova shape di partenza del DM e con REC 20090609_174117 con 200 modi

directory:adsec_data/Data_20090619_181219,
10hz

1s _181410--_181704

4s _181755--_181924

6s _182015--_182225

10s _182325--_182600
20Hz

1s _182704---_182914

4s _183020--_183255

6s _183409--_183540

10s _183649--_184014

TEST KALMAN.

ccd39:800Hz. counts:1000
TT:9.
g:0.02
Kalman.:KF7_7Hz_damp01_sigma7e9_g0999-pist_state8_AR_142233_100...

save data: /towerdata/adsec_data/Data_20090619_162305/.

nota: this test has been succesful,...

Nota: the system Adsec after applying a kalman filter , the adsec shows RETRY. Changing back to the last working kalman the system keeps showing RETRY. after trying to load a shape (eg) the ADsec cames in FAILURE STATUS.

to recover the secondary and the Adsec it was necessary to recover fail option.
to solve this kind of faults we don'├Čt need to shutdown (rip) the secondary .....

-- FrancescaPieralli - 2009-06-19
Topic revision: r6 - 01 Jul 2009, FrancescaPieralli
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback