LBT672b related Logs
Tables of Opt Int Mat and Flattening Commands
Ago/Sep 2011 Log. First Seeing Limited Run
TelLogLBT672b20110829
TelLogLBT672b20110830
TelLogLBT672b20110831
TelLogLBT672b20110901
TelLogLBT672b20110902
TelLogLBT672b20110903
Flattening
TelLogLBT672b20110904
Flattening2, modes, astig vs elevation
TelLogLBT672b20110905
Flattening3, modes 51x, astig vs elevation
TelLogLBT672b20110908
Electrical astigm, slew for sanity check
TelLogLBT672b20111025
crate 1 siggen failure - armando analisys - marco patch
Dec 2011 Log. Testing and seeing limited run
TelLogLBT672b20111207
System startup after cleanroom activities
TelLogLBT672b20111208
nighttime actuators test, first alignment and test of flattening
TelLogLBT672b20111209
alignment and flattening
TelLogLBT672b20111210
flattening refinement, modal basi sampling
TelLogLBT672b20111212
flattening refinement, modes verification
TelLogLBT672b20111218
trefoil pistoning test
TelLogLBT672b20111219
trefoil pistoning test
TelLogLBT672b20111220
best flat ever
TelLogLBT672b20120128
MX - start of the night and fixing previous nights bugs
TelLogLBT672b20120129
MX - start of the night and fixing previous nights bugs
TelLogLBT672b20120130
MX - found COMMUNICATION ERROR during the night
TelLogLBT672b20120210
MX - found COMMUNICATION ERROR during the night
Mar/Apr 2012 Log. Commissioning RUN#X
TelLogLBT672b20120408
AR - RR-DayTime. RIP continui del Seconario da fermo
Apr/May 2012 Log. Commissioning RUN#Y
TelLogLBT672b20120421
AR - di nuovo saltata la
SigGen
(durante notte scientifica)
Jun 2012
TelLogLBT672b20120621
September 2012 Log. Commissioning RUN#Z
TelLogLBT672b20120908
Optical alignment and test of kl verification (original 201112 basis-kl v9)
TelLogLBT672b20120909
Flattening and measurement of kl-slaved basis ( kl v10). mirror modes sampling
TelLogLBT672b20120910
test on jumping actuators. test with download of diagnostic data
TelLogLBT672b20120911
test on new ff matrix acquisition and comparison
TelLogLBT672b20120912
sampling of new kl basis (kl v12 provided by mx). squid piston run sampling. zonal if sampling. comparison of kl v10 vs kl v12
TelLogLBT672b20120913
TelLogLBT672b20120914
TelLogLBT672b20120918
Nighttime
TelLogLBT672b20120919
Nighttime
May 2013 Log optical calibration after refurbishment
TelLogLBT672b20150527
Optical alignment and actuators configuration
TelLogLBT672b20150528
ff matrix acquisition and flattening
TelLogLBT672b20150529
flattening refinement, sampling of modal basis
MEMO
ModifiedRoutines
to be added to SVN
--
ArmandoRiccardi
- 29 Aug 2011
E
dit
|
A
ttach
|
P
rint version
|
H
istory
: r39
<
r38
<
r37
<
r36
|
B
acklinks
|
V
iew wiki text
|
Edit
w
iki text
|
M
ore topic actions
Topic revision: r39 - 29 May 2015,
RunaBriguglio
FLAO
Log In
Toolbox
Create New Topic
Index
Search
Changes
Notifications
RSS Feed
Preferences
Users
Groups
Webs
ARGOS
AdaptiveOptics
Commissioning
Engineering
FLAO
Instrumentation
LBTI
Main
MountainOperations
Operators
PartnerObserving
ProjectManagement
Safety
Sandbox
Software
SummerShutdown
System
Copyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki?
Send feedback