Final HP position at alignment

1.8 3.0 6.25 72 -2 0

the Z position is very off, likely due to a wrong position of the interferometer

Actuators configuration

the configuration produced in clean room was changes to allow on-sky operation

a copy of the clean room configuration is found in :

/local/aomeas/adsec_calib/configuration/672b/TS5/elec/20150513_174644/elec.txt

we copy the current elec.txt in elec_doug.txt

total number of actuator removed from position :2 14 32 373 511 541 same procedure for fastdiagn.param (old file moved into fastdiagn_doug.param)

same procedure for calibration data as the ff:

ff meas in lab by guido: 20150513_183121, copied in $ADOPT_SOURCE/calib/adsec/672b/data/

the old .fits files (doug?) copied into a new subfolder doug

we made adsc_stop

make install-conf

make install-calib

adsc_start

the we restarted the aos from tcs gui

system restarted

list of actuators jumped after statrtup

541 (pos)

2 (pos)

act #541 large jump in position. to be removed

bad approach, we restart

there is no reason to restore closed loop operation on the actuators that were disabled before refurbishment. the one that can be used as those whose magnets were glued.

!!during the refurbishment, no special activity was done on the faulty actuators.

so we will restore the previous configuration (elec and fastdiagn) and reinsert the actuator whose magnets were glued.

list: 5 6 20 36 37 39 116 229 245 340 341 343 371 373 375 583

as we obseved that new actuators are jumping, we open the loop on them

this new configuration seems to work,

we set the shell thorugh the command line to avoid loading the flat (fsm_set_flat(/no_flat)). to do this we enabled lab mode (telescope at zenith) and stop-started adsecarb to have it aligned with current condition

we saved a default flat: 20150528_014800_no_flat.sav

the crate 0 has a larger force rms

Current actuator configuration

wo_curr: (2)

2 19
wo_pos:(40)

2 19 32 45 50 70 112 113 117 130 173
201 210 230 235 243 291 304 337 339 370
374 402 422 451 459 464 483 539 541 546
563 570 571 579 581 594 625 626 654
wo_icc: (30)

216 217 328 440 441 552 664 665 104 366
500 8 9 71 56 515 254 63 472 30
286 513 626 625 497 202 542 211
14 511


check on recent fastdiagn log

we found a large number of jumped actuators. see file logfast1.txt in adopt_log
0 24 42 165 173 259 266 295 348 368 376 409 451 478 482 530 578 654

mostly when the shell was ripped. was such behaviour already observed?

Topic revision: r4 - 28 May 2015, RunaBriguglio
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.