-- RunaBriguglio - 09 Sep 2012

New flattening command:

used intmat 20111210_20512.

flattening result=20120909_124550

identification of the bumps in the mode images

we identified a number of spots on the modes verification images. these spots correspond to actuator jumps.

/local/aomeas/adsec_calib/flat/20120909_bump_identification.sav

lower bump:

pushing act #291 we obtain a very similar effect

539

Verification of the slaved-actuators base

(kl=/local/aomeas/adsec_calib/if_functions/20111210_pureKLs_01/full_m2v.fits, modified in May 2012).

?? does this base actually correspond to the slaved actuators? a verification is requested

Tracknum modes amp
20120909_141836 0-49  
20120909_145616 50-99 100
20120909_142144 100-149 80
20120909_142332 150-199 70
20120909_142439 200-249 50
20120909_142544 250-299 50
20120909_142652 300-349 40
20120909_142805 350-399 40
20120909_142921 400-449 30
20120909_143119 450-499 30
20120909_143234 500-549 30
20120909_143356 550-599 30
20120909_143528 600-649 30

Act#539 removed some jumps have been observed during the intmat acquire with the W

KL slave verification:!!! error on the sampling procedure. see log of tomorrow

Mirror modes sampling

casual measurements, because we planned to reacquire the KL base but we forgot the /kl keyword in the
Tracknum modes amp
20120910_025045 0-49 150
20120910_025217 50-99 100
20120910_025942 100-149 80
20120910_030122 150-199 70
20120910_030310 200-249 50
20120910_030512 250-299 50
20120910_030641 300-349 40
20120910_030810 350-399 40
20120910_031027 400-449 30
20120910_031214 450-499 30
20120910_031356 500-549 30
20120910_031608 550-599 30
20120910_031813 600-649 30
Topic revision: r8 - 12 Sep 2012, RunaBriguglio
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.