su segnalazione di JC trovato specchio in panic con
SigGen del crate#1 con il solito problema
l'inizio del problema:
idlctrl.L |INF| 139005|2012-04-21 10:19:44.250624| MAIN > Executing command: errcode= process_dump('/local/aolog/current/ADAPTIVE-SECONDARY_00001335003524_20120421_101844.log') & print, errcode
idlctrl.L |INF| 139006|2012-04-21 10:19:51.243063| MAIN > -- PROCESS DUMP START --
idlctrl.L |INF| 139007|2012-04-21 10:19:51.243118| MAIN > Sat Apr 21 10:19:44 2012
idlctrl.L |INF| 139008|2012-04-21 10:19:51.243146| MAIN > Get info from housekeeper.L variables...done
idlctrl.L |INF| 139009|2012-04-21 10:19:51.243174| MAIN > Get info from masterdiagnostic.L dump file: ADAPTIVE-SECONDARY_00001335003524_20120421_101844.log...dump loaded.
idlctrl.L |INF| 139010|2012-04-21 10:19:51.243206| MAIN > Get info from fastdiagn.L variables...done
idlctrl.L |INF| 139011|2012-04-21 10:19:51.243231| MAIN > Get info from fastdiagn.L variables...done
idlctrl.L |INF| 139012|2012-04-21 10:19:51.243257| MAIN > No variables in Alarm for family: CHCURRAVERAGE
idlctrl.L |INF| 139013|2012-04-21 10:19:51.243282| MAIN > Fam: CHDISTAVERAGE in Alarm over indexes: 200 203 204 205 206 208 209 211 212 213 214 215 216 217 218 219 220 221 222 223
idlctrl.L |INF| 139014|2012-04-21 10:19:51.243308| MAIN > No variables in Alarm for family: CHINTCONTROLCURRENT
idlctrl.L |INF| 139015|2012-04-21 10:19:51.243338| MAIN > Fam: CHDISTRMS in Alarm over indexes: 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 202 203 204 205 206 207 208 209 211 212 213 214 215 218 219 220 221 222 223
idlctrl.L |INF| 139016|2012-04-21 10:19:51.243364| MAIN > No variables in Alarm for family: CHCURRRMS
idlctrl.L |INF| 139017|2012-04-21 10:19:51.243388| MAIN > No variables in Alarm for family: MODES
idlctrl.L |INF| 139018|2012-04-21 10:19:51.243458| MAIN > No variables in Alarm for family: CHNEWDELTACOMMAND
idlctrl.L |INF| 139019|2012-04-21 10:19:51.243481| MAIN > No variables in Alarm for family: CHFFCOMMAND
idlctrl.L |INF| 139020|2012-04-21 10:19:51.243504| MAIN > No variables in Alarm for family: CHFFPURECURRENT
idlctrl.L |INF| 139021|2012-04-21 10:19:51.243530| MAIN > Get info from housekeeper.L variables configuration...done
idlctrl.L |INF| 139022|2012-04-21 10:19:51.243557| MAIN > Get info from adamhousekeeper.L variables...done
idlctrl.L |INF| 139023|2012-04-21 10:19:51.243599| MAIN > Get info from housekeeper.L variables...done
idlctrl.L |INF| 139024|2012-04-21 10:19:51.243627| MAIN > Get info from adamhousekeeper.L variables...done
idlctrl.L |INF| 139025|2012-04-21 10:19:51.243650| MAIN > Adam watchdog not expired.
idlctrl.L |INF| 139026|2012-04-21 10:19:51.243674| MAIN > Ethernet connection watchdog on Switch BCU not expired.
idlctrl.L |INF| 139027|2012-04-21 10:19:51.243697| MAIN > Ethernet connection watchdog on Crate BCU not expired.
idlctrl.L |INF| 139028|2012-04-21 10:19:51.243720| MAIN > All global counters are progressing
idlctrl.L |INF| 139029|2012-04-21 10:19:51.243742| MAIN > DSP board watchdog not expired.
idlctrl.L |INF| 139030|2012-04-21 10:19:51.243764| MAIN > Distance threshold check analysis result:
idlctrl.L |INF| 139031|2012-04-21 10:19:51.243789| MAIN > Not stable capacitive sensor on CH ID: 119 137 (times: 932243931798)
idlctrl.L |INF| 139032|2012-04-21 10:19:51.243813| MAIN > Consider to remove the actuators with highest fault frequency from the close loop list.
idlctrl.L |INF| 139033|2012-04-21 10:19:51.243840| MAIN > Consider to remove the other detected actuators from the integrator control loop list.
idlctrl.L |INF| 139034|2012-04-21 10:19:51.243866| MAIN > Temperature analysis result:
idlctrl.L |INF| 139035|2012-04-21 10:19:51.243893| MAIN > Warn temperature value of: SWITCHSTRATIXTEMP - index: 0 - value [C deg]=47.000000
idlctrl.L |INF| 139036|2012-04-21 10:19:51.243920| MAIN > Consider to fix the temperature ranges in houskeeper process or substitute the PT sensors.
idlctrl.L |INF| 139037|2012-04-21 10:19:51.243944| MAIN > OVERCURRENT probability for TOTAL PUSH CURRENT: 29.3%
idlctrl.L |INF| 139038|2012-04-21 10:19:51.243967| MAIN > OVERCURRENT probability for TOTAL PULL CURRENT: 212.9%
idlctrl.L |INF| 139039|2012-04-21 10:19:51.243991| MAIN > OVERCURRENT probability for SINGLE CRATE TOTAL CURRENT: 26.6%
idlctrl.L |INF| 139040|2012-04-21 10:19:51.244013| MAIN > -- PROCESS DUMP END --
/local/aomeas/adsec_calib/noise/20120421_132243: test_noise_script shell rippata onda intera
per uscire dal panic-mode e resettare l'onda 1/8:
13:35UT: adsc_stop
14:11UT: adsc_start
/local/aomeas/adsec_calib/noise/20120421_141824: test_noise_script shell rippata onda 1/8
14:33UT: set_flat: tutto OK
dovuto rippare perche' telescopio mosso verso l'orizzonte
di nuovo settata e eseguito test_noise_script
/local/aomeas/adsec_calib/noise/20120421_155843
--
ArmandoRiccardi - 21 Apr 2012