Lo specchio con il solo set della shell Rippa di continuo senza fare nulla
Analisi dei Dump della Master:
Dopo il setting, in condizioni statiche:
idlctrl.L |INF| 12775|2012-04-08 21:39:03.093853| MAIN > Get info from masterdiagnostic.L dump file: ADAPTIVE-SECONDARY_00001333921075_20120408_213755.log...dump loaded.
idlctrl.L |INF| 14525|2012-04-08 21:56:10.348455| MAIN > Get info from masterdiagnostic.L dump file: ADAPTIVE-SECONDARY_00001333922127_20120408_215527.log...dump loaded.
idlctrl.L |INF| 2145|2012-04-08 22:23:09.150332| MAIN > Get info from masterdiagnostic.L dump file: ADAPTIVE-SECONDARY_00001333923721_20120408_222201.log...dump loaded.
idlctrl.L |INF| 2467|2012-04-08 22:33:06.589912| MAIN > Get info from masterdiagnostic.L dump file: ADAPTIVE-SECONDARY_00001333924377_20120408_223257.log...dump loaded.
Durante un loop chiuso:
idlctrl.L |INF| 3053|2012-04-08 22:41:33.954167| MAIN > Get info from masterdiagnostic.L dump file: ADAPTIVE-SECONDARY_00001333924886_20120408_224126.log...dump loaded.
durante il set flat:
idlctrl.L |INF| 3766|2012-04-08 22:43:54.728182| MAIN > Get info from masterdiagnostic.L dump file: ADAPTIVE-SECONDARY_00001333924989_20120408_224309.log...dump loaded.
idlctrl.L |INF| 4159|2012-04-08 22:46:12.263226| MAIN > Get info from masterdiagnostic.L dump file: ADAPTIVE-SECONDARY_00001333925122_20120408_224522.log...dump loaded.
20120408_213755
master dump tutto uguale
Housekeeper Voltaggio
20120408_215527
master dump tutto uguale
Housekeeper Voltaggio
20120408_222201
Parlato con Marco
Suggerisce di raffreddare la switch oe/o cambiarla con uno spare
18:10: lasciata aperat la porta (valvola cooling del cabinet e' gia' tutta aperta)
temperatura della switch (stratix) va da 48C a 39C
settiamo la shell e vediamo se regge
18:20
01:27:53 di nuovo RIP
ADAPTIVE-SECONDARY_00001333934873_20120409_012753.log
Stessa fenomenologia del _20120408_222201 e del
BUG:
--
ArmandoRiccardi - 08 Apr 2012