idlctrl.L          |INF|     14718|2012-01-30 07:42:55.371199|             MAIN > Executing command: errcode= fsm_ho_offload('/tmp/highorderoffloadvector.fits') & print, errcode
idlctrl.L          |INF|     14719|2012-01-30 07:42:55.847280|             MAIN > HO_Offload forced to be skipped
idlctrl.L          |INF|     14720|2012-01-30 07:42:55.847431|             MAIN > Applying LUT correction for low order Zernike
idlctrl.L          |INF|     14721|2012-01-30 07:42:55.847500|             MAIN > elevation is [deg] 58.447467
idlctrl.L          |INF|     14722|2012-01-30 07:42:55.847554|             MAIN > z6 is [m rms] 2.83893e-06
idlctrl.L          |INF|     14723|2012-01-30 07:42:55.847612|             MAIN > % WRITE_SEQ: READING ERROR BCU
idlctrl.L          |INF|     14724|2012-01-30 07:42:55.847730|             MAIN >        -1009

A un certo punto della notte si e' avuto l'errore qui sopra.

Guardando il mirrorCtrl:
mirrorctrl.L       |ERR|       370|2012-01-30 07:42:55.834869|             MAIN > ******** FAILED PACKET FROM BCU 6 - CMD TIMEOUT CA *******
mirrorctrl.L       |ERR|       371|2012-01-30 07:42:55.835009| BCUCOMMANDHANDLE > BcuCommandHandler::handleBcuReply: REQUEST COMPLETED but FAILED :-(
mirrorctrl.L       |ERR|       372|2012-01-30 07:49:22.870248|             MAIN > ******** FAILED PACKET FROM BCU 6 - CMD TIMEOUT CA *******
mirrorctrl.L       |ERR|       373|2012-01-30 07:49:22.870329| BCUCOMMANDHANDLE > BcuCommandHandler::handleBcuReply: REQUEST COMPLETED but FAILED :-(
mirrorctrl.L       |ERR|       374|2012-01-30 07:50:43.932084|             MAIN > ******** FAILED PACKET FROM BCU 6 - CMD TIMEOUT CA *******
mirrorctrl.L       |ERR|       375|2012-01-30 07:50:43.932610| BCUCOMMANDHANDLE > BcuCommandHandler::handleBcuReply: REQUEST COMPLETED but FAILED :-(

PESSIMO!!! CA dalla BCU 6 del mirrorctrl (crate 3) durante le normali operazioni.Solo il DSP era bloccato (la SRAM e la SDRAM funzionavano...) Sintomo di qualcosa di piu' grave? Fatto a tratti Capire come rendere chiaro un evento del genere ( noi faremo cosi': trapping) Perche' non e' partito il recover fail.

-- MarcoXompero - 30 Jan 2012
Topic revision: r1 - 30 Jan 2012, MarcoXompero
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.