-- RunaBriguglio - 09 Dec 2011

Alignment

The initial alignment, as from yesterday coordinates, was completely off. A huge amount of focus was detected.

Troubles with 4D

Hexapod: 4.9 -1.22 4.65 641 886 0

M3 -1335 150 0 Selection -48.3

Flattening: new Int Matrix

Tracknum Modes amp  
20111209_193325 0-50 100  
New definition of 4D mask
20111209_200618 0-50 100  
20111209_201925 51-250 100  
20111209_210125 251-500 70  
20111209_212025 501-662 70  

Flattening: Flattening command

Modes Electrical data Optical data WFE notes Forces minmax
50 20111209_194110 20111209_194110_50modes_NOCOMA 58 coma was corrected  
New mask
50 20111209_201141 20111209_201141_flat50modes 64 datafill  
50 20111209_201650 20111209_201650_flat50modes 66 no datafill -0.11; 0.13
250 20111209_203155 20111209_203155_flat250modes 46   -0.12; 0.09
500 20111209_211833 20111209_211833_flat500modes 46   -0.14; 0.15
632 20111209_214331 20111209_214331_flat632 44   -0.13; 0.17