Bcu crate #5 of unit A was found not responding to the ping.
The FASTLINK communication is ok that means NO PROBLEMS with BCU ITSELF BUT more PROBABLY ETH CONNECTION.
Started @
fastdiagn.R |INF| 875|2011-09-01 07:08:12.849339| MAIN > Changed reference forces: Averaged reference force is 0 [FastDiagnostic.cpp:271]
fastdiagn.R |INF| 887|2011-09-01 07:08:13.835367| FAST > Processed 52 cycles of 7634 vars in 1.06 s ( 49 Hz). HW frame rate 50 [DiagnApp.cpp:838]
Stop @
fastdiagn.R |INF| 15917|2011-09-01 07:28:48.458233| FAST > Processed 49 cycles of 7634 vars in 1.01 s ( 48.3 Hz). HW frame rate 50.3 [DiagnApp.cpp:838]
fastdiagn.R |WAR| 15929|2011-09-01 07:28:50.541463| MAIN > Timeout - Will emergencyReact next loop [FastDiagnostic.cpp:1093]
TOTAL 20 minutes working as yesterday. Damage of eth chip????
Test on unit A: the light seems to arrive so the TX can be ok. It means that the problem can be related in RX.
Switch UP unit @ Thu Sep 1 22:53:09 CEST 2011 ----> NOT WORKING
Proceeding with shimming of interferometer.
Test on unit B purposed by Roberto done by Micheal.
Identified actuators affected by 528DSP vulcano effect: DSP[523, 529, 532] removed from ICC
AdSec 672B interferometer optical alignment
HP position at manual alignment
[0, 0, 4.5, 30, -20, 0]
M3 Position at manual alingment
[ 600, 200, 0]. Selection =-48.35
The mirror image is a bit outside the frame. Moving M3 might solve. tested negative tip offset result encouraging.
A tip offset of -100 corresponds to hp delta movements of [-0.1 0 0 50 -5 0]
M3 tip position with full pupil within the frame: -900 ,200 0
HP= [-2, -0.22, 4.5, 480, 157, 0]
FInal HP position at alignment
HP= [1.37, 0.64, 4.69, 396.67, 506.8, 0] Coma free pointing value: tip=1.4. -0.2
M3 -900, 200
Flattening procedure
tracknum |
modes |
amp |
20110902_033807 |
0-10 |
80 |
|
|
|
--
MarcoXompero - 01 Sep 2011