Unit B switched on. One actuator LOST (126DSP/452MIR).

Removed from control. started again.

Flux registration at horizon.

Found to have 11 L/min (read 17.6 from fluxmeter)

It was decided to reduce the unit flux to 9 L/min and 2L/min for the cabinet.

Half Open the cabinet, the flux was found to be with almost no changes in the unit, and cabinet has 2> liter per minute.

Tried to close and open unit side: fluxmeter reading went to zero and went up to 11.8 L/min.

Total Flux measured: 14.75 l/min

cabinet closed: total Flux: 12.75 l/min and read 12.5.

Cabinet completely open and unit open: unit read 11.7L/min / total flux 15

Cabinet half open: unit 11.7 (read) , total 14.75 L/min

The fluxmeter reading was wrong @ start but seems correct at the end of measurements.

TSS test on unit A: not working on crates 3 and 4.(fig1)

Test interferometer fiber. ---> negative: the trigger was not detected in the tree house UL.

Around 126DSP found vulcano effect (700nm delta shape with ICC on and off). We try to remove DSP114-125-127 from ICC.

Actuator DSP#172/MIR315 was found with 2m readings. Removed.

Actuator DSP#142/MIR526 was found with 2m readings. Removed.

Actuator DSP#568/MIR425 was found with 2m readings. Removed.

Actuator DSP#236/MIR454 was found with 2m readings. Removed.

Interferometer OK: - remember mount disks

- if you manually start trigger you have to use set_if_trigger() and set_disturb(/ena)

TSS unit B is ALWAYS applied when the switch into the cabinet is ON.(verified with SPI reading)

AOS communication test with AOarb adsecsx: OK.

Actuator DSP#390/MIR397 was found with 2m readings. Removed.Total 6 removed actuators.

Actuator DSP#237/MIR455 was found with 2m readings. Removed.Total7 removed actuators.

Actuator DSP#71/MIR297 was found with 2m readings. Removed.Total 8 removed actuators.

The flow meter is stopped.

-- MarcoXompero - 30 Aug 2011
  • (fig 1) SPI reading from TSS (unitA):
    tss_not_working.png

  • (fig2): unitA - 1/8 square wave - NO TSS applied:
    unitAnoTSS.png

  • (fig3): unitA - 1/8 square wave - SS applied:
    unitATSS.png

  • (fig 4): UNIT B vulcano effect around 126 DSP (current) :
    vul1.png

  • (fig 5): UNIT B vulcano effect around 126 DSP (deltaposition w/wo ICC):
    vul1dpos.png

  • (fig 6) removed actuators:

  • (fig 6) removed actuators::
    badacts.png
I Attachment Action Size Date Who Comment
badacts.pngpng badacts.png manage 31 K 31 Aug 2011 - 02:17 MarcoXompero (fig 6) removed actuators:
removed_acts.pngpng removed_acts.png manage 31 K 31 Aug 2011 - 02:14 MarcoXompero (fig 6) removed actuators
tss_not_working.pngpng tss_not_working.png manage 30 K 30 Aug 2011 - 18:49 MarcoXompero SPI reading from TSS
unitATSS.pngpng unitATSS.png manage 27 K 30 Aug 2011 - 22:57 MarcoXompero (fig3): unitA - 1/8 square wave - SS applied
unitAnoTSS.pngpng unitAnoTSS.png manage 30 K 30 Aug 2011 - 22:56 MarcoXompero (fig2): unitA - 1/8 square wave - NO TSS applied
vul1.pngpng vul1.png manage 58 K 30 Aug 2011 - 22:44 MarcoXompero (fig 2): vulcano effect around 126 DSP (current)