-- RunaBriguglio - 06 Feb 2016

Alignment

alignment lost:

new alignment: -1.1 -1.92 3.4 87 -136

fsm_load_shape(myflat, force_max_mode=200); myflat=20160205_005424

new flattening

using intmat 20160206_004935 using 20 modes to correct astigmatsm

flat: 20160206_151126

20160206_150000_TS4.mask

20160206_150000_TS4.ini

4Sight restarted

if sampling

test of if sampling

20160206_152529

Measurement of mirror modes

tracknum dataset: trackts4

20160206_152529 to be used for testing
Tracknum modes amp niter notes
20160206_153648 0-14 700 51 fringes disappeared
20160206_153836 0-14 500 51 fringes disappeared, to be checked, maybe good
20160206_154023 0-14 100 51 very small signal
20160206_154227 0-14 250 51 this is now used
20160206_154409 15-29 250 51  
20160206_154542 15-29 150 51 this is to be used
20160206_154717 30-44 150 51  
20160206_154849 45-59 150 51  
20160206_155056 60-74 150 51  
20160206_155235 75-89 150 51 not to be used
20160206_155416 75-89 120 51  
20160206_155552 90-104 100 51  
20160206_155824 105-124 100 35  
20160206_155953 105-124 80 35 backup
20160206_160656 125-143 80 35  
20160206_160833 144-162 80 35  
20160206_161139 163-181 80 35  
20160206_161331 182-200 80 35 fringes may to large?? can be good
20160206_161520 182-200 70 35 backup
20160206_161650 201-219 70 35  
20160206_161858 220-238 70 35  
20160206_162227 239-257 70 35  
20160206_162427 258-276 60 35  
20160206_162612 277-295 60 35  
20160206_162746 296-314 60 35  
20160206_162937 315-333 60 35  
20160206_163111 334-352 60 35  
20160206_163236 353-371 60 35  
20160206_163407 372-390 60 35  
20160206_163552 391-409 60 35  
20160206_163718 410-428 60 35 maybe too late, no trigger??
20160206_163852 429-447 60 35  
20160206_164029 448-466 60 35  
20160206_164201 467-485 60 35  
20160206_164329 486-504 60 35  
20160206_164502 505-523 60 35  
20160206_164639 524-542 60 35  
20160206_164816 543-561 60 35  
20160206_165027 562-580 60 35  
20160206_165209 581-599 60 35  
20160206_165353 600-618 60 35  
20160206_165521 619-637 60 35  
20160206_165701 638-641 60 35  
backup measurements
20160206_170021 30-48 150 35  
20160206_170231 49-67 150 35  
20160206_170406 68-86 150 35  
20160206_170540 87-105 120 35  
20160206_170700 106-124 120 35  
20160206_170836 125-143 100 35  
20160206_171003 144-162 100 35  
20160206_171135 163-181 80 35  
20160206_171320 182-200 80 35  
20160206_171512 201-219 80 35  
20160206_171641 220-238 80 35  
20160206_171815 239-257 70 35  
20160206_171939 258-276 60 35  
20160206_172059 277-295 60 35  
20160206_172219 296-314 60 35  
20160206_172338 315-333 60 35  
20160206_172457 334-352 60 35  
20160206_172612 353-371 60 35  
20160206_172737 372-390 60 35  
20160206_172856 391-409 60 35  
20160206_173027 410-428 60 35  
20160206_173147 429-447 60 35  
20160206_173347 448-466 60 35  
20160206_173506 467-485 60 35  
20160206_173620 486-504 60 35  
20160206_173734 505-523 60 35  
20160206_173842 524-542 60 35  
Topic revision: r2 - 06 Feb 2016, RunaBriguglio