Test of load shape

continuing from yesterday

a=get_phasemap(25,10,save=tracknum)

Shape loaded Tracknum image electrical data wfe note
20130829_070833 20130830_042756 20130830_042756_stability_flattening_result.sav   large bumps
20130829_070833 20130830_054241 20130830_054241 _stability_flattening_result.sav   large bumps
20130829_070833 20130830_075959 20130830_054241 _stability_flattening_result.sav   large bumps
20130830_065415 20130830_080859 20130830_080859_stability_flattening_result.sav   bumps
20130830_074941 20130830_081214 20130830_081214_stability_flattening_result.sav   bumps
20130829_070833 20130830_085058 20130830_085058_stability_default.sav    
20130830_065415 20130830_090155 20130830_090155_stability_flattening_result.sav    
20130830_074941 20130830_090630 20130830_090630_stability_flattening_result.sav    
20130830_065415 20130830_102302 20130830_102302_stability_flattening_result.sav   cold
20130829_070833 20130830_164352 20130830_164352_stability_default.sav   astigmatism
20130830_065415 20130830_164800 20130830_164800_stability_flattening_result.sav   astigmatism
20130830_074941 20130830_164944 20130830_164944_stability_flattening_result.sav   astigmatism
20130829_070833 20130831_044244 20130831_044244_stability_default.sav   no astigmatism
20130830_065415 20130831_052710 20130831_052710_stability_flattening_result.sav    
20130830_074941 20130831_053219 20130831_053219_stability_flattening_result.sav    
         

New intmat produced

20130826_150704/20130831_053959_flat_data_661modes.sav
Tracknum File Notes
20130826_150704 20130831_053959_flat_data_661modes.sav raw data produced 1000x1000
20130826_150704 20130831_060541_flat_data_661modes.sav raw data produced 1000x1000, intmat built 200x200
the new production of 20130826_150704 data is required to have a backup basis just in case

then, build_int_mat(tr, act_sampling=8) i.e. 2x the typical resolution of the im

Flattening

Tracknum IM nmodes Result WFE forces notes
20130828_151119 500 20130831_054334   -0.25+0.13  
20130828_151119 650 20130831_054749      
20130826_150704 500 20130831_055552 39 -0.3+0.15  
20130826_150704/20130831_053959_flat_data_661modes.sav 650 20130831_060006 30    
20130826_150704/20130831_053959_flat_data_661modes.sav 650 20130831_061045 32 -0.28+0.15 some convection
the new matrix (20130826_150704/20130831_053959_flat_data_661modes.sav) works as the standard one, but a bit less forces are required

Test of flattening with 200x200 interaction matrix

Tracknum IM nmodes Result WFE phasemap forces notes
20130831_060541_flat_data_661modes.sav 650 20130831_063035 34 20130831_063035 -0.24+0.17  
20130831_060541_flat_data_661modes.sav 650 20130831_064646 30 20130831_064646 -0.25+0.18 opt_int_mat_reduce2(650, track=im1, ave=100)

20130831_064646 is the default flat

GOOD RESULT!

New computazion of PMZ and pos2modes

changing the fitting threshold, from 1e-4 to 0.3e-5, saved in 20130831_085422

updating pmz and pos2modes

testing
Mode applied amplitude Tracknum notes Reference (flat)
Z5        
Z6        
Z7        
         
         
         

Test of flattening pushing the mousehole actuators

procedure
  1. load_shape
  2. err=write_bias_curr(actlist,0.25)
  3. load a large (optical) mask
  4. flatten
  5. err=write_bias_curr(actlist,0.25)
in general, the worst point is that corresponding to the edge of the gluing. so a custom mask for that point will be designed
Step IMK tracknum Tracknum Forces  
1   20130831_064646 -0.19+0.14  
2     -0.21+0.2  
3   20130831_mask-biascurr_test4.mask    
4 20130831_060541_flat_data_661modes.sav 20130831_071341 -0.52+0.2  
5     -  
1   20130830_074941 -0.15+0.2  
2,3   20130831_mask-biascurr_test5.mask    
4 20130831_060541_flat_data_661modes.sav 20130831_072531 -0.42+0.2  
5        
1   20130830_074941 -0.15+0.15  
2     -0.15+0.2  
3   20130831_mask-biascurr_test6.mask    
4 20130831_060541_flat_data_661modes.sav 20130831_073604 -0.44+0.2  
5        
1   20130830_074941 -0.16+0.16  
2     -0.15+0.2  
3   20130831_mask-biascurr_test7.mask    
4 20130831_060541_flat_data_661modes.sav 20130831_075423 -0.36+0.2  
5        
1   20130830_074941    
2        
3   20130831_mask-biascurr_test8.mask    
4 20130831_060541_flat_data_661modes.sav 20130831_080206 -0.36+0.2  
5        
1        
2        
3   20130831_mask-biascurr_test10.mask -0.47+0.2  
    mousehole_deformation (classic)    
THIS WORKS
Step IM Tracknum mask forces
set_flat        
write_bias curr        
load_shape        
mask     20130826_mask-TS4-covering_mouse_hole_deformation.mask  
flat 20130831_060541_flat_data_661modes.sav 20130831_093635   -0.23
         

verification of the procedure depicted above

Action Shape tracknum Image tracknum IM Result Tracknum mask forces WFE
set_flat              
load_shape 20130831_061045 20130831_094304          
write_bias_curr(actlist,0.25)   20130831_094414          
load_shape 20130831_061045 20130831_094615          
flattening   20130831_095006

20130831_060541_

flat_data_661modes.sav

20130831_095006 20130826_mask-TS4-covering_mouse_hole_deformation.mask -0.24+0.2 32
flattening   20130831_095826

20130831_060541_

flat_data_661modes.sav

20130831_095826 20130831_mask-biascurr_test10.mask    
load_shape              
flattening   20130831_100523   20130831_100523 20130831_mask-biascurr_test10.mask -0.35+20  
load_shape              
flattening   20130831_102559   20130831_102559 20130826_mask-TS4-covering_mouse_hole_deformation.mask -0.23+0.2 28
20130826_mask-TS4-covering_mouse_hole_deformation.mask

Last Flat

IM Tracknum Result nmodes image notes

20130831_060541_

flat_data_661modes.sav

20130831_102559 650 20130831_102559 with 441,552 @0.25

20130831_060541_

flat_data_661modes.sav

20130831_135549 650   without 441,552 @0.25

Long exposure image

/towerdata/meas/adsec_calib/phasemap/20130831_130424/phasemap.sav

test of modified load shape procedure

with different action on internal actuators

Test shape applied max mode applied phasemap electrical forces
old 20130831_102559 283 20130831_133140 20130831_133140_stability_flattening_result.sav -0.2+0.2
old 20130830_074941 249 20130831_133716 20130831_133716_stability_flattening_result.sav  
new 20130831_102559 658 20130831_133939 20130831_133939_stability_flattening_result.sav -0.25+0.2
new 20130830_074941 248 20130831_134216 20130831_134216_stability_flattening_result.sav  
!! some mismatch given by the application of the bias current

test restarted

write_bias_current(actlist, 0.)

Test shape applied max mode applied phasemap electrical forces
new 20130831_135549 577 20130831_135857 20130831_135857_stability_flattening_result.sav -0.3+0.2
new 20130830_074941 248 20130831_140057 20130831_140057_stability_flattening_result.sav -0.18+0.18
old 20130831_135549 334 20130831_140301 20130831_140301_stability_flattening_result.sav -0.19+0.11
old 20130830_074941 249 20130831_140502 20130831_140502_stability_flattening_result.sav -0.19+0.11

Backup measurement of mirror modes

Tracknum Modes amp notes
20130831_113123 0-14 amprms=0.7e-6  
20130831_113244 15-29 amprms=0.5e-6 lost?
20130831_113532 15-29 amprms=0.4e-6  
20130831_113719 30-44 amprms=0.2e-6  
20130831_113844 45-59 amprms=0.18e-6  
20130831_113955 60-74 amprms=0.18e-6  
20130831_114113 75-89 amprms=0.16e-6  
20130831_114251 90-104    
20130831_114412 105-119    
20130831_114521 120-134    
20130831_114628 135-149    
20130831_114735 150-164    
20130831_114851 165-179    
20130831_114953 180-194    
20130831_115056 195-209    
20130831_115203 210-224    
20130831_115309 225-239    
20130831_115412 240-254    
20130831_115515 255-269    
20130831_115641 270-284    
20130831_115744 285-299    
20130831_115854 300-314    
20130831_120045 315-329    
20130831_120201 330-344    
20130831_120338 345-359 FORCE_SCALE=0.45/0.3  
20130831_120521 360-374 FORCE_SCALE=0.45/0.3  
20130831_120734 375-389 FORCE_SCALE=0.45/0.3  
20130831_120845 390-404 FORCE_SCALE=0.45/0.3  
20130831_121258 405-419 FORCE_SCALE=0.45/0.3  
20130831_121403 420-434 FORCE_SCALE=0.45/0.3 lost?
20130831_121525 420-434 FORCE_SCALE=0.45/0.3  
20130831_121636 435-449 FORCE_SCALE=0.48/0.3  
20130831_121741 450-464 FORCE_SCALE=0.48/0.3  
20130831_121845 465-479 FORCE_SCALE=0.48/0.3  
20130831_121947 480-494 FORCE_SCALE=0.48/0.3 lost?
20130831_122155 480-494 FORCE_SCALE=0.48/0.3  
20130831_122306 495-509 FORCE_SCALE=0.52/0.3  
20130831_122415 510-524 FORCE_SCALE=0.55/0.3  
20130831_122534 525-539 FORCE_SCALE=0.55/0.3  
20130831_122657 540-554 FORCE_SCALE=0.55/0.3  
20130831_122809 555-569 FORCE_SCALE=0.5/0.3 lost?
20130831_122928 555-569 FORCE_SCALE=0.5/0.3  
20130831_123048 570-584 FORCE_SCALE=0.5/0.3  
20130831_123202 585-599 FORCE_SCALE=0.51/0.3  
20130831_123310 600-614 FORCE_SCALE=0.51/0.3  
20130831_123415 615-629 FORCE_SCALE=0.51/0.3  
20130831_123524 630-644 FORCE_SCALE=0.51/0.3  
20130831_123632 645-659 FORCE_SCALE=0.51/0.3  