Mario's communication test on unit LBT672a

LBT672a showd problems durin last night, moreover there are hints that communications has problem triggering problems on Switch-BCU

MatLab extensive communication test has been run from 05-Jul-2011 17:02:52 to 05-Jul-2011 20:38:11.

Normal behaviour:

05-Jul-2011 20:38:11 tot cnt= 212730521 - good cnt= 212730299 - BER: 9.196383e-14
Getting system status... ambient temp: 20 - ambient hum: 36.93 - crate temp: 34 - board temp: 47 - min/max stratix temp: 35/ 47
Diagnostic link wr-rd test... 1 OK!
Test of global counter... OK!

log file here: /home/aoacct/matlab/LibrerieDev/ComTest/v2.02/logs/20110705T170251_screen.txt

To run the test:
in MatLab:
clear all
init
mgp_op_wrsame_dsp(bcu_dsp,bcu_dsp,1,p_enabled,0,SWITCH_CONN_ID);
cold_test

-- ArmandoRiccardi - 05 Jul 2011
Topic revision: r1 - 05 Jul 2011, ArmandoRiccardi
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback