-- RunaBriguglio - 03 Jul 2011

ASM startup

AOSet and focal station = bent gregorian front

gain=0

rec=20091118_141410: bin1, 601 modi, mod=3

WFS startup

complete without ccd47

bin=1

freq=990

mod=3

Testing with openclose/opencloseao

openclose: it calls openloop, closeloop

opnecloseao: it calls stopao, startao. the shape is loaded at every stop_ao!!

First test, no ovs (last telescope configuration)

the loop is now closed using the parameters given above.

Test N iterations RIP?
openclose 10 no
opencloseao 10 no

Second test

fsm_run_ao, fsm_skip_recovery modified

error at the very first open loop (maybe the loop was not closed at the beginning?)

FUNCTWARNING > FunctWarning SWITCHSAFESKIPCOUNTER-0000 -9.23779e-06

Test N iterations RIP?
openclose 10 no
the shell remained in offloaded position (maxforce=0.8N) at the end of the procedure

log in $ADOPT_LOG logopenclose, from 21:56:20 to 21:58:34:

fsm_stop_ao(/HOLD)

fsm_set_gain('/home/aoacct/AO/current//calib//adsec/current/M2C/KL/gain/gain0.fits')

fsm_run_ao(990, 1, 0.00116279) (1/990=0.0010101, bin1, freq ovs < freq loop)

fsm_stop_ao(/HOLD) =

freeze=1

noloadshape=1

fsm_skip_recovery(/FORCE, FREEZE=freeze, NOLOADSHAPE=noloadshape)

wait, 5*rtr.oversampling_time > 0.2

Test N iterations RIP?
openclose 10 no
the shell has a normal shape at the end

Test N iterations RIP?
openclose 10 no

Test N iterations RIP?
openclose 10 no

Test N iterations RIP?
opencloseao 10 no

log of operations in logopencloseao.txt, from 22:17:08 to 22:19:44:

fsm_stop_ao()

fsm_set_gain('/home/aoacct/AO/current//calib//adsec/current/M2C/KL/gain/gain0.fits')

fsm_run_ao(990, 1, 0.0107527) (1/990=0.0010101, bin1, freq ovs < freq loop)

Test N iterations RIP?
opencloseao 20 no

opencloseao calls also a TTOffload, while openclose does not